Desa VMH3000TPA Checking GAS Connections, Pressure Testing Gas Supply Piping System

Page 13

INSTALLATION

Checking Gas Connections

13

INSTALLATION

Continued

CHECKING GAS CONNECTIONS

WARNING: Test all gas piping and connections for leaks after installing or servicing. Correct all leaks at once.

WARNING: Never use an open flame to check for a leak. Apply a noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)

1.Disconnect appliance with its appliance main gas valve (con- trol valve) and equipment shutoff valve from gas supply pip- ing system. Pressures in excess of 1/2 psig will damage heater regulator.

2.Cap off open end of gas pipe where equipment shutoff valve was connected.

3.Pressurize supply piping system by either opening propane/LP sup- ply tank valve for propane/LP gas or opening main gas valve lo- cated on or near gas meter for natural gas, or using compressed air.

4.Check all joints of gas supply piping system. Apply a noncor- rosive leak detection fluid to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

5.Correct all leaks at once.

6.Light heater (see Operating Heater, pages 14 and 15). Check all other internal joints for leaks.

7.Turn off heater (see To Turn Off Gas to Appliance, page 15).

8.Replace front panel.

Open

Equipment

Shutoff

Valve

Closed

Figure 20 - Equipment Shutoff Valve

Thermostat Gas

Valve Location

Gas Meter

Equipment

Shutoff

Valve

1.Close equipment shutoff valve (see Figure 20).

2.Pressurize supply piping system by either opening propane/LP sup- ply tank valve for propane/LP gas or opening main gas valve lo- cated on or near gas meter for natural gas, or using compressed air.

3.Check all joints from gas meter to equipment shutoff valve (see Figure 21) for natural gas, or to propane/LP supply tank (see Figure 22). Apply a noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

Pressure Testing Heater Gas Connections

1.Open equipment shutoff valve (see Figure 20).

2.Open main gas valve located on or near gas meter for natural gas or open propane/LP supply tank valve for propane/LP gas.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from equipment shutoff valve to thermostat gas valve (see Figure 21 or 22). Apply a noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak.

Figure 21 - Checking Gas Joints (Natural Gas)

Thermostat Gas

Valve Location

Propane/LP

Supply Tank

Equipment

Shutoff

Valve

Figure 22 - Checking Gas Joints (Propane/LP Gas)

For morevisit www..com

109889

Image 13
Contents 15,000 to 30,000 Btu/Hr With Thermostat What to do if YOU Smell GASSafety Information Table of ContentsProduct Identification Local CodesUnpacking Assembling Heater Product FeaturesAIR for Combustion and Ventilation AssemblyAttaching Brass Front Trim to Front Panel Assembling and Attaching Brass TrimDetermining FRESH-AIR Flow for Heater Location Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Items InstallationCheck GAS Type Locating HeaterThermostat Sensing Bulb Installation OptionsMounting Heater to Wall Mounting Heater on Optional Hearth Base Installing Bottom Mounting ScrewsPlacing Heater On Mounting Bracket Mounting Heater to Optional Hearth Base Securing Hearth Base to FloorSee Instructions Included With Mantel Kit Assembling Mantel Internally-tinned copper tubing may be used in cer Connecting to GAS SupplyPressure Testing Heater Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Operating Heater For Your Safety Read Before LightingLighting Instructions Inspecting Burner Cleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceCabinet Air PassagewaysObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Observed Problem Possible Cause Replacement Parts SpecificationsService Hints Technical ServiceAccessories RFN30TA RFP30TA VMH3000TNA VMH3000TPA Illustrated Parts BreakdownNJF-8C Parts ListFBD Parts CentralsOwners Registration Form Postage Required 109889 Not a UPC

VMH3000TPA specifications

The Desa VMH3000TPA is a state-of-the-art heating appliance designed to deliver efficient warmth while ensuring user comfort and convenience. This model is widely recognized for its innovative technologies, smart design, and eco-friendly features, making it an ideal choice for residential spaces.

One of the standout features of the VMH3000TPA is its powerful heating capacity. With a robust output of 30,000 BTUs, it is engineered to heat large areas effectively, making it perfect for living rooms, open-plan spaces, or even workshops. Users can expect a consistent and reliable warmth throughout the chilly seasons, enhancing home comfort while reducing reliance on traditional heating systems.

The VMH3000TPA incorporates advanced heating technology, including a variable speed blower that allows for more efficient heat distribution. This feature ensures that warm air circulates evenly throughout the room, eliminating cold spots and creating a cozy atmosphere. Additionally, the unit has a programmable thermostat, allowing users to set and maintain their desired temperature easily.

For safety, the VMH3000TPA is equipped with multiple safety features, including an automatic shut-off function that activates if the unit overheats or tips over. This ensures peace of mind, especially in households with children or pets. Its durable construction includes a fireproof casing and a heat-resistant glass front, designed to withstand high temperatures while maintaining an attractive appearance.

The Desa VMH3000TPA is also designed with energy efficiency in mind. It operates on propane or natural gas, providing a cleaner-burning alternative to traditional heating methods. This model complies with environmental regulations, helping to reduce carbon emissions while lowering energy costs.

Another remarkable aspect is its user-friendly interface, which includes remote control functionality. Users can conveniently adjust settings from a distance, enhancing usability and comfort. This modern appliance is not just a heating solution; it is a blend of technology and design, ensuring that it complements any home décor while providing effective heating solutions.