Desa HDVF3018N Operating Heater, For Your Safety Read Before LIGHTING ,  Lighting Instructions 

Page 17

Operating Heater

FOR YOUR SAFETY

READ BEFORE LIGHTING 

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result causing property damage, per- sonal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service tech- nician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

 LIGHTING

INSTRUCTIONS 

WARNING

If fireplace has glass doors, never operate this heater with glass doors closed. If you op- erate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Make sure there are no obstructions across openings of fireplace.

You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before run- ning heater.

NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Orange flame will also be pres- ent. Open damper or window to vent smell. This will only last a few hours.

Note: Home owners generally prefer to op- erate their heater with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full flames of the HI heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat.

WARNING: Damper handle will be hot if heater has been running.

1.STOP! Read the safety information in column 1.

2.Make sure equipment shutoff valve is fully open.

3.Press in and turn control knob clockwise to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor.

If you smell gas, STOP! Follow “B” in the safety information, column 1. If you don’t smell gas, go to the next step.

119421-01A

www.desatech.com

17

Image 17
Contents Variable Manually Controlled Models Also Design-Certified As Vented Decorative AppliancesSafety Information Table of ContentsSafety Information Local Codes Product Identification Product FeaturesUnpacking Air for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationProviding Adequate Ventilation Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationVent-Free Operation Only InstallationInstallation and Clearances Marble, Tile, etc. Above Fireplace Mantel ClearancesFloor Clearances Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Installing Heater Base AssemblyChimney Minimum Permanent Area of Various Standard Round FluesAttaching Base Assembly to Fireplace Floor Dual Burner Model Connecting to GAS SupplyNatural Checking GAS ConnectionsPropane/LP Test Pressures Equal To or Less Than Psig 3.5 kPa Installing LogsPressure Testing Heater Gas Connections Installing Front Log #1  LIGHTING INSTRUCTIONS  For Your Safety Read Before LIGHTING Operating Heater Operating Heater  MANUAL Lighting Procedure VARIABLE Control Operation  TO Turn OFF GAS to APPLIANCE Inspecting Burners Cleaning MaintenancePilot Flame Pattern Burner Primary AIR HolesBlow air into the primary air holes on the injector holder LogsObserved Problem Possible Cause Remedy TroubleshootingMaintenance, TroubleshootingStatement above Gas leak. See WarningTechnical Service SpecificationsService Hints Replacement PartsFireplace Hood AccessoriesEquipment Shutoff Valve GA5010 Variable Manually-Controlled Models HDVF3018P and HDVF3018N Illustrated Parts BreakdownParts List Limited Warranty VENT-FREE GAS LOG Heaters Warranty InformationKeep this Warranty

HDVF3018N, HDVF3018P specifications

The Desa HDVF3018P and HDVF3018N are advanced heating solutions that exemplify innovation and efficiency in the heating appliance market. They are designed to provide reliable and effective heating for residential and commercial spaces, ensuring comfort during colder months while also prioritizing energy efficiency.

One of the standout features of the HDVF3018 series is its powerful heat output. With an impressive BTU rating, these units are capable of efficiently warming large areas, making them ideal for both homes and businesses. This makes them a popular choice for those looking to maintain a comfortable environment during winter.

In terms of design, the HDVF3018P and HDVF3018N boast sleek, modern aesthetics that allow them to blend seamlessly with various interior styles. Their compact footprints make them suitable for smaller spaces without sacrificing performance. Additionally, these units are equipped with advanced safety features, including automatic shut-off mechanisms that ensure reliable operation without compromising user safety.

The HDVF3018 series incorporates cutting-edge technology to optimize heating efficiency. For instance, they utilize a variable speed blower, which not only enhances heat distribution but also reduces energy consumption. This feature helps residents and businesses save on heating costs while decreasing their environmental impact.

Another notable characteristic of these units is their user-friendly controls. The HDVF3018P and HDVF3018N come with intuitive interfaces that allow users to easily adjust temperature settings and programming schedules. This ensures that the heating systems operate at desired levels without needing constant manual adjustments.

In terms of fuel options, the HDVF3018 series is versatile, catering to various preferences and needs. Whether using propane, natural gas, or other fuel types, these units provide flexibility for users to choose the best option for their specific heating requirements.

Furthermore, both models are engineered with durability in mind. High-quality materials contribute to their longevity, making them a worthwhile investment for those seeking dependable heating solutions.

In summary, the Desa HDVF3018P and HDVF3018N deliver a powerful combination of reliable performance, modern design, and advanced technology. Their ability to efficiently heat spaces while providing user-friendly operation and safety make them excellent choices for anyone in need of a high-quality heating appliance.