Desa HDVF3018P Operating Heater,  VARIABLE Control Operation,  TO Turn OFF GAS to APPLIANCE 

Page 18

OPERATING HEATER

Continued

5.Slightly press and turn control knob coun-

terclockwise to the PILOT position.

Press in control knob for five (5) seconds (see Figure 22).

Note: You may be running this heater for the first time after hooking up to gas sup- ply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system.

6.With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

8.Slightly press and turn control knob

counterclockwise to desired heat- ing level. The burner(s) should light. Set control knob to any heat level between HI and LO.

WARNING: Do not operate heater between PILOT and HI positions.

Ignitor Button

Control Knob

 

Figure 22 - Control Knob and Ignitor

Button Location

Ignitor

Pilot Burner

Electrode

 

Thermocouple

Figure 23 - Pilot

 VARIABLE CONTROL

OPERATION

The variable control valve can be set to any heat setting and flame height desired, by simply turning the control knob until that setting is attained. Even the lowest setting provides re- alistic, dancing yellow flames. Selecting higher settings produces greater heat output. This results in increased heating comfort.

CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve.

 TO TURN OFF GAS TO APPLIANCE 

Shutting Off Heater

1. Press in and turn control knob clockwise

to the HI position.

2. Turn control knob clockwise to the pilot position.

3. Press in control knob and turn clockwise to the OFF position.

Shutting Off Burner(s) Only (pilot stays lit)

1. Turn control knob clockwise to the HI position.

2. Press in and turn control knob clockwise to the pilot position.

 MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 5 under Lighting Instructions, page 17.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8, under Lighting Instructions, column 1. 

18

www.desatech.com

119421-01A

Image 18
Contents Also Design-Certified As Vented Decorative Appliances Variable Manually Controlled ModelsTable of Contents Safety InformationSafety Information Local Codes Unpacking Product FeaturesProduct Identification Air for Combustion VentilationAIR for Combustion Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Check GAS TypeInstallation Installation and ClearancesVent-Free Operation Only Mantel Clearances Marble, Tile, etc. Above FireplaceInstalling Damper Clamp Accessory for Vented Operation Floor ClearancesChimney Minimum Permanent Installing Heater Base AssemblyInstallation Items Needed Area of Various Standard Round FluesConnecting to GAS Supply Attaching Base Assembly to Fireplace Floor Dual Burner ModelChecking GAS Connections Propane/LPNatural Installing Logs Pressure Testing Heater Gas ConnectionsTest Pressures Equal To or Less Than Psig 3.5 kPa Installing Front Log #1 For Your Safety Read Before LIGHTING  Operating Heater LIGHTING INSTRUCTIONS   VARIABLE Control Operation  MANUAL Lighting ProcedureOperating Heater  TO Turn OFF GAS to APPLIANCE Pilot Flame Pattern Cleaning MaintenanceInspecting Burners Burner Primary AIR HolesLogs Blow air into the primary air holes on the injector holderTroubleshooting Observed Problem Possible Cause RemedyTroubleshooting Maintenance,Gas leak. See Warning Statement aboveService Hints SpecificationsTechnical Service Replacement PartsAccessories Equipment Shutoff Valve GA5010Fireplace Hood Illustrated Parts Breakdown Variable Manually-Controlled Models HDVF3018P and HDVF3018NParts List Warranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS LOG Heaters

HDVF3018N, HDVF3018P specifications

The Desa HDVF3018P and HDVF3018N are advanced heating solutions that exemplify innovation and efficiency in the heating appliance market. They are designed to provide reliable and effective heating for residential and commercial spaces, ensuring comfort during colder months while also prioritizing energy efficiency.

One of the standout features of the HDVF3018 series is its powerful heat output. With an impressive BTU rating, these units are capable of efficiently warming large areas, making them ideal for both homes and businesses. This makes them a popular choice for those looking to maintain a comfortable environment during winter.

In terms of design, the HDVF3018P and HDVF3018N boast sleek, modern aesthetics that allow them to blend seamlessly with various interior styles. Their compact footprints make them suitable for smaller spaces without sacrificing performance. Additionally, these units are equipped with advanced safety features, including automatic shut-off mechanisms that ensure reliable operation without compromising user safety.

The HDVF3018 series incorporates cutting-edge technology to optimize heating efficiency. For instance, they utilize a variable speed blower, which not only enhances heat distribution but also reduces energy consumption. This feature helps residents and businesses save on heating costs while decreasing their environmental impact.

Another notable characteristic of these units is their user-friendly controls. The HDVF3018P and HDVF3018N come with intuitive interfaces that allow users to easily adjust temperature settings and programming schedules. This ensures that the heating systems operate at desired levels without needing constant manual adjustments.

In terms of fuel options, the HDVF3018 series is versatile, catering to various preferences and needs. Whether using propane, natural gas, or other fuel types, these units provide flexibility for users to choose the best option for their specific heating requirements.

Furthermore, both models are engineered with durability in mind. High-quality materials contribute to their longevity, making them a worthwhile investment for those seeking dependable heating solutions.

In summary, the Desa HDVF3018P and HDVF3018N deliver a powerful combination of reliable performance, modern design, and advanced technology. Their ability to efficiently heat spaces while providing user-friendly operation and safety make them excellent choices for anyone in need of a high-quality heating appliance.