Desa HDVF3018P, HDVF3018N Installing Heater Base Assembly, Chimney Minimum Permanent

Page 12

INSTALLATION

Continued

See chart below for minimum permanent flue opening you must provide. Attach damper clamp so the minimum permanent flue opening will be maintained at all times.

Chimney

Minimum Permanent

Height

Flue Opening

6' to 15'

39 sq. inches

15' to 30'

29 sq. inches

 

 

Area of Various Standard

Round Flues

Diameter

Area

5"

20 sq. inches

6"

29 sq. inches

7"

9 sq. inches

8"

51 sq. inches

 

 

INSTALLING HEATER BASE ASSEMBLY

CAUTION: Do not remove the data plates attached to the heater base assembly. The data plates contain important warranty and safety information.

WARNING: You must secure this heater to fireplace floor. If not, heater will move when you adjust controls. Moving heater may cause a gas leak.

WARNING: If installing in a sunken fireplace, special care is needed. You must raise the fireplace floor to allow access to heater control panel. This will insure adequate air flow and guard against sooting and controls being damaged. Raise fireplace floor with noncombus- tible material. Make sure material is secure.

CAUTION: Do not pick up heater base assembly by the burner. This could damage heater. Only handle base as- sembly by grates.

IMPORTANT: Make sure the heater burners are level. If heater is not level, heater will not work properly.

Installation Items Needed

• hardware package (provided with heater)

• approved flexible gas hose (not provided) (if allowed by local codes)

• sealant resistant to propane (propane/LP) gas, not provided

• electric drill with 3/16" drill bit

• flathead screwdriver

1.Apply pipe joint sealant lightly to male threads of the fitting to be threaded into gas regulator. Connect approved flexible gas hose to gas regulator of heater (see Figure 11).

IMPORTANT: Hold gas regulator with wrench when connecting flexible gas hose.

2.Locate masonry screws in hardware package.

3.Position heater base assembly in fireplace.

4.Place logs in their proper position on heater base, see Installing Logs on page 15.

5.Center heater base and logs front-to-back and side-to-side in fireplace.

6.Carefully remove logs without moving heater base.

7.Mark screw locations through holes in mounting brackets (see Figure 12, page 13). If installing in a brick-bottom fireplace, mark screw locations in mortar joint of bricks.

8.Remove heater base from fireplace.

9.Drill holes at marked locations using 3/16" drill bit.

10.Attach base assembly to fireplace floor using two masonry screws (in hardware package) (see Figure 12, page 13).

Flexible Gas Hose

(if allowed by local codes)

Heater Gas

Regulator

Fitting

Figure 11 - Attaching Flexible Gas Hose

to Heater Gas Regulator

12

www.desatech.com

119421-01A

Image 12
Contents Also Design-Certified As Vented Decorative Appliances Variable Manually Controlled ModelsTable of Contents Safety InformationSafety Information Local Codes Product Features Product IdentificationUnpacking Air for Combustion VentilationAIR for Combustion Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Check GAS TypeInstallation Installation and ClearancesVent-Free Operation Only Mantel Clearances Marble, Tile, etc. Above FireplaceInstalling Damper Clamp Accessory for Vented Operation Floor ClearancesInstalling Heater Base Assembly Installation Items NeededChimney Minimum Permanent Area of Various Standard Round FluesConnecting to GAS Supply Attaching Base Assembly to Fireplace Floor Dual Burner ModelChecking GAS Connections Propane/LPNatural Installing Logs Pressure Testing Heater Gas ConnectionsTest Pressures Equal To or Less Than Psig 3.5 kPa Installing Front Log #1 For Your Safety Read Before LIGHTING  Operating Heater LIGHTING INSTRUCTIONS   MANUAL Lighting Procedure Operating Heater VARIABLE Control Operation  TO Turn OFF GAS to APPLIANCE Cleaning Maintenance Inspecting BurnersPilot Flame Pattern Burner Primary AIR HolesLogs Blow air into the primary air holes on the injector holderTroubleshooting Observed Problem Possible Cause RemedyTroubleshooting Maintenance,Gas leak. See Warning Statement aboveSpecifications Technical ServiceService Hints Replacement PartsAccessories Equipment Shutoff Valve GA5010Fireplace Hood Illustrated Parts Breakdown Variable Manually-Controlled Models HDVF3018P and HDVF3018NParts List Warranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS LOG Heaters

HDVF3018N, HDVF3018P specifications

The Desa HDVF3018P and HDVF3018N are advanced heating solutions that exemplify innovation and efficiency in the heating appliance market. They are designed to provide reliable and effective heating for residential and commercial spaces, ensuring comfort during colder months while also prioritizing energy efficiency.

One of the standout features of the HDVF3018 series is its powerful heat output. With an impressive BTU rating, these units are capable of efficiently warming large areas, making them ideal for both homes and businesses. This makes them a popular choice for those looking to maintain a comfortable environment during winter.

In terms of design, the HDVF3018P and HDVF3018N boast sleek, modern aesthetics that allow them to blend seamlessly with various interior styles. Their compact footprints make them suitable for smaller spaces without sacrificing performance. Additionally, these units are equipped with advanced safety features, including automatic shut-off mechanisms that ensure reliable operation without compromising user safety.

The HDVF3018 series incorporates cutting-edge technology to optimize heating efficiency. For instance, they utilize a variable speed blower, which not only enhances heat distribution but also reduces energy consumption. This feature helps residents and businesses save on heating costs while decreasing their environmental impact.

Another notable characteristic of these units is their user-friendly controls. The HDVF3018P and HDVF3018N come with intuitive interfaces that allow users to easily adjust temperature settings and programming schedules. This ensures that the heating systems operate at desired levels without needing constant manual adjustments.

In terms of fuel options, the HDVF3018 series is versatile, catering to various preferences and needs. Whether using propane, natural gas, or other fuel types, these units provide flexibility for users to choose the best option for their specific heating requirements.

Furthermore, both models are engineered with durability in mind. High-quality materials contribute to their longevity, making them a worthwhile investment for those seeking dependable heating solutions.

In summary, the Desa HDVF3018P and HDVF3018N deliver a powerful combination of reliable performance, modern design, and advanced technology. Their ability to efficiently heat spaces while providing user-friendly operation and safety make them excellent choices for anyone in need of a high-quality heating appliance.