Desa HDVF3018N, HDVF3018P Installation and Clearances, Vent-Free Operation Only

Page 9

INSTALLATION

Continued

INSTALLATION AND CLEARANCES

(Vent-Free Operation Only)

WARNING: Maintain the minimum clearances. If you can, provide greater clearances from floor, ceiling and adjoining wall.

MINIMUM FIREPLACE CLEARANCE

TO COMBUSTIBLE MATERIALS

Log Size

 

Side Wall

 

Ceiling

18"

 

16"

 

 

42"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOG SIZING REQUIREMENTS

 

 

 

Minimum Firebox

Log

 

 

 

 

 

 

 

 

 

 

Front

Rear *

Size

 

Height

 

Depth

Width

Width

 

 

 

 

 

 

 

 

18"

17"

14"

24"

 

20"

* Measured at 14" depth.

Carefully follow the instructions below. This will ensure safe installation into a masonry, UL127- listed manufactured fireplace or certified vent-free firebox.

Minimum Clearances For Side

Combustible Material, Side Wall and

Ceiling

A. Clearances from the side of the fireplace cabinet to any combustible material and wall should follow diagram in Figure 4.

Example: The face of a mantel, bookshelf, etc. is made of combustible material and protrudes 3 1/2" from the wall. This combus- tible material must be 4" from the side of the fireplace opening (see Figure 4).

Note: When installing your gas logs into a manufactured firebox, follow firebox manufacturer’s instructions for minimum clearances to combustible materials.

B. Clearances from the top of the fireplace open- ing to the ceiling should not be less than 42".

Example

*

*Minimum 16" from Side Wall

Figure 4 - Minimum Clearance for

Combustible to Wall

NOTICE: Manual control heaters maybeusedasaventedproduct. If so, you must always run heater with chimney flue damper open. If running heater with damper open, noncombustible material above fireplace opening is not needed. Go to Installing Damper Clamp Accessory for Vented Operation, page 11.

Minimum Noncombustible Material

Clearances

If Not Using Mantel

Note: If using a mantel, proceed to If Using Mantel, page 10. If not using a mantel, follow the information below.

You must have noncombustible material(s) above the fireplace opening. Noncombustible materials (such as slate, marble, tile, etc.) must be at least 1/2" thick. With sheet metal, you must have non- combustible material behind it. Noncombustible material must extend at least 8" up (for all mod- els). If noncombustible material is less than 12", you must install the fireplace hood accessory (24" and 30" models only). See Figure 5, page 10 for minimum clearances.

IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open. Go to Installing Damper Clamp Accessory for Vented Operation, page 11.

119421-01Awww.desatech.com

Image 9
Contents Variable Manually Controlled Models Also Design-Certified As Vented Decorative AppliancesSafety Information Table of ContentsSafety Information Local Codes Product Identification Product FeaturesUnpacking Air for Combustion VentilationAIR for Combustion Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Check GAS Type InstallationInstallation Installation and ClearancesVent-Free Operation Only Marble, Tile, etc. Above Fireplace Mantel ClearancesFloor Clearances Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Installing Heater Base AssemblyChimney Minimum Permanent Area of Various Standard Round FluesAttaching Base Assembly to Fireplace Floor Dual Burner Model Connecting to GAS SupplyChecking GAS Connections Propane/LPNatural Installing Logs Pressure Testing Heater Gas ConnectionsTest Pressures Equal To or Less Than Psig 3.5 kPa Installing Front Log #1 For Your Safety Read Before LIGHTING  Operating Heater LIGHTING INSTRUCTIONS  Operating Heater  MANUAL Lighting Procedure VARIABLE Control Operation  TO Turn OFF GAS to APPLIANCE Inspecting Burners Cleaning MaintenancePilot Flame Pattern Burner Primary AIR HolesBlow air into the primary air holes on the injector holder LogsObserved Problem Possible Cause Remedy TroubleshootingMaintenance, TroubleshootingStatement above Gas leak. See WarningTechnical Service SpecificationsService Hints Replacement PartsAccessories Equipment Shutoff Valve GA5010Fireplace Hood Variable Manually-Controlled Models HDVF3018P and HDVF3018N Illustrated Parts BreakdownParts List Warranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS LOG Heaters

HDVF3018N, HDVF3018P specifications

The Desa HDVF3018P and HDVF3018N are advanced heating solutions that exemplify innovation and efficiency in the heating appliance market. They are designed to provide reliable and effective heating for residential and commercial spaces, ensuring comfort during colder months while also prioritizing energy efficiency.

One of the standout features of the HDVF3018 series is its powerful heat output. With an impressive BTU rating, these units are capable of efficiently warming large areas, making them ideal for both homes and businesses. This makes them a popular choice for those looking to maintain a comfortable environment during winter.

In terms of design, the HDVF3018P and HDVF3018N boast sleek, modern aesthetics that allow them to blend seamlessly with various interior styles. Their compact footprints make them suitable for smaller spaces without sacrificing performance. Additionally, these units are equipped with advanced safety features, including automatic shut-off mechanisms that ensure reliable operation without compromising user safety.

The HDVF3018 series incorporates cutting-edge technology to optimize heating efficiency. For instance, they utilize a variable speed blower, which not only enhances heat distribution but also reduces energy consumption. This feature helps residents and businesses save on heating costs while decreasing their environmental impact.

Another notable characteristic of these units is their user-friendly controls. The HDVF3018P and HDVF3018N come with intuitive interfaces that allow users to easily adjust temperature settings and programming schedules. This ensures that the heating systems operate at desired levels without needing constant manual adjustments.

In terms of fuel options, the HDVF3018 series is versatile, catering to various preferences and needs. Whether using propane, natural gas, or other fuel types, these units provide flexibility for users to choose the best option for their specific heating requirements.

Furthermore, both models are engineered with durability in mind. High-quality materials contribute to their longevity, making them a worthwhile investment for those seeking dependable heating solutions.

In summary, the Desa HDVF3018P and HDVF3018N deliver a powerful combination of reliable performance, modern design, and advanced technology. Their ability to efficiently heat spaces while providing user-friendly operation and safety make them excellent choices for anyone in need of a high-quality heating appliance.