Desa GVC50PA, GVC35PA, GVC65PA installation manual Fresh AIR for, Ventilation Air from Outdoors

Page 16

 

FRESH AIR FOR

 

Draft Hood Spillage: This is a hazardous situation. Draft hood spillage re-

 

 

 

 

 

COMBUSTION

 

leases poisonous carbon monoxide gas into your home.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DANGER

 

 

 

 

 

AND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VENTILATION

 

 

 

Carbon monoxide poisoning may lead to death!

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Continued

 

If draft hood spillage occurs, check for blocked flue connectors, vent pipes, and

 

 

 

 

 

chimneys. If you find blockage, remove. Test again for spillage. If spillage still

 

 

 

 

 

occurs or there was no blockage, you need more fresh, outside air in the house. You

 

 

 

 

 

must provide additional fresh-air ventilation. Follow the steps below at once.

 

 

 

 

 

A. Open a window near the appliance(s) at least two inches. Test again for

 

 

 

 

 

 

 

spillage. If spillage does not stop, open window more and retest. If spillage

 

 

 

 

 

 

 

stops, keep window open while running appliance(s). Supply fresh, outside

 

 

 

 

 

 

 

air by a permanent method as soon as possible. If spillage still occurs, leave

 

 

 

 

 

 

 

window open and go to next step.

 

 

 

 

 

 

 

 

 

 

 

 

 

B. If you have a fireplace, open a window or door near it at least two inches.

 

 

 

 

 

 

 

Test again for spillage. If spillage does not stop, open window or door more

 

 

 

 

 

 

 

and retest. If spillage stops, keep window or door open while using fire-

 

 

 

 

 

 

 

place. Supply fresh, outside air by a permanent method as soon as possible.

 

 

 

 

 

 

 

If spillage still occurs, leave window or door open and go to next step.

 

 

 

 

 

C. If you have kitchen and bathroom exhaust fans, turn them off. Test again for

 

 

 

 

 

 

 

spillage. If spillage stops, do not use exhaust fans. Turn off circuit breakers for

 

 

 

 

 

 

 

fans if possible. Permanently supply fresh, outside air as soon as possible.

 

 

 

 

 

Providing Permanent Fresh-Air Ventilation

 

 

 

 

 

 

 

 

 

 

 

 

 

If draft hood spillage occurs, you must permanently supply fresh, outside air to the

 

 

 

 

 

inside of your house. Provide extra fresh air by using ventilation grills or ducts.

 

 

 

 

 

Connect these items directly to the outdoors or spaces open to the outdoors. These

 

 

 

 

 

spaces include attics and crawl spaces. If you install this heater in an area with

 

 

 

 

 

other gas appliances, you must total the BTU/Hr input rating of all appliances.

 

 

 

 

 

Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1. It lists fresh-air

 

 

 

 

 

requirements for fuel-burning appliances.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IMPORTANT

 

 

 

 

 

 

 

 

Do not provide openings for inlet or outlet air into attic

 

 

 

 

 

 

 

 

if attic has a thermostat controlled power vent.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Chimney

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

or Gas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vent

Outlet

 

 

 

 

 

Ventilated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Attic

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outlet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To Attic

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Crawl

 

 

 

 

 

 

 

 

 

 

Inlet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Space

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inlet Air

 

 

 

 

 

 

 

 

 

 

Ventilated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Crawl Space

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 10 - Ventilation Air from Outdoors

 

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100748

Image 16
Contents For Your Safety OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS Contents Safety InformationElectrical shock, and carbon monoxide poisoning Carbon monoxide poisoning may lead to deathSafety Information Product IdentificationFeatures Installing HeaterLocal Codes UnpackingInstalling Heater Locating HeaterVenting Heater Venting Heater Do not vent heater in any of the following ways see FigureVenting Heater Proper Size Vent Installing Connecting to GAS SupplyQualified service person must connect heater to gas Supply. Follow all local codesGas Connection Checking GAS Connections Test all gas piping and connections for leaks after installIng or servicing. Correct all leaks at once Fresh AIR for Combustion and Ventilation Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Draft Hood Spillage TestFresh AIR for Ventilation Air from OutdoorsConfined area has an air volume of less than 50 cubic 15 to make sure fresh air ventilation is adequateOperating Heater For Your Safety Read Before LightingLighting Instructions Viewing Pilot Manual Lighting Procedure Blower OperationTo Turn OFF GAS to Appliance Shutting Off HeaterPilot Flame Pattern Inspecting Pilot and Burner FlameBurner Flame Pattern Correct Burner Flame Pattern Cleaning MaintenanceTrouble Shooting Unless you need gas supply for testing, shut off manualShutoff valve before servicing. Only a qualified service Turn off and unplug heater and let cool before servicingProblem Cause TroubleObserved Possible Problem Cause Remedy TROUBLE- ShootingStatement at top Connections,Service Procedures Removing Control Valve and Burner TubeRemoving Burner Wiring DiagramBlower Changing Burner OrificeService AccessoriesTechnical HintsOrdering Replacement Parts Under WarrantyParts Not Under Warranty PartsIllustrated Parts List Cabinet AssemblyBurner Assembly Parts List Warranty Information Limited Warranty Vanguard Vented Propane GAS Heaters

GVC50PA, GVC35PA, GVC65PA specifications

The Desa GVC65PA, GVC35PA, and GVC50PA are advanced gas-fired ventless fireplaces that are designed to deliver efficiency, convenience, and aesthetic appeal. These models are particularly popular in modern homes for their ability to provide warmth without the burdens of traditional venting systems.

The GVC65PA stands out for its powerful heating capacity, making it ideal for larger spaces. It boasts a maximum output of 65,000 BTUs, ensuring that even the coldest rooms can be comfortably heated. This model is equipped with an innovative digital thermostat, allowing users to maintain their desired temperature with precision. Its remote control feature adds convenience, enabling homeowners to adjust settings from across the room.

The GVC35PA, on the other hand, is tailored for smaller spaces and is perfect for those looking for warmth in a compact format. With a maximum output of 35,000 BTUs, it efficiently heats rooms without overwhelming them. This model features a sleek design with a front access panel for easy maintenance. Its variable flame height control adds to its appeal, allowing users to customize the ambiance of their living space.

For those desiring a mid-range option, the GVC50PA is a versatile choice. With an output of 50,000 BTUs, it strikes a balance between capacity and efficiency, making it suitable for diverse room sizes. This model incorporates advanced safety features, such as an oxygen depletion sensor that automatically shuts off the unit if oxygen levels drop too low, providing peace of mind for users.

All three models are equipped with ceramic fiber logs that replicate the appearance of real wood, enhancing the visual aesthetics of the fireplace. These fireplaces utilize advanced burner technology, ensuring even heat distribution and maximizing fuel efficiency. The ventless design means that they can be installed in virtually any room without the need for complex venting systems, making them a practical choice for homeowners.

In summary, the Desa GVC65PA, GVC35PA, and GVC50PA represent the pinnacle of modern ventless fireplace technology. They offer a combination of aesthetic charm, powerful heating capabilities, and safety features, making them an attractive addition to any home. With their ease of installation and operation, these fireplaces are an excellent option for anyone seeking cozy warmth in a stylish package.