Desa GVC65PA, GVC35PA, GVC50PA installation manual Fresh AIR for Combustion and Ventilation

Page 14

FRESH AIR FOR COMBUSTION AND VENTILATION

WARNING

This heater must have fresh air for proper operation. If not, poor fuel combustion and improper venting of flue gases will result. Carbon monoxide poisoning from backed-up flue gases could occur. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.

Today’s homes are built more energy efficient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.

While it is good to make your home energy efficient, it is not good to make it too airtight. Your home needs to breath. If your home is too airtight, fresh air has little chance of entering in. This could be dangerous if you have fuel-burning appliances. These appliances need fresh, outside air for proper combustion and ventilation.

Exhaust fans, fireplaces, clothes dryers, and fuel-burning appliances draw air from the house to operate. This heater is a fuel-burning appliance. It uses air from inside the house for combustion. It also uses this air as a draft for venting. This draft air helps move combustion gases through the vent pipe to the outdoors. If your house is too airtight, there is not enough fresh air for these items to use. Fresh air may draw back into the house through venting flues and chimneys. This will keep fuel- burning appliances from venting properly. This may cause them to release poison- ous carbon monoxide gas into your home. It is very important to provide enough fresh air to run all fuel-burning appliances.

DANGER

Carbon monoxide poisoning may lead to death!

Carbon monoxide is a colorless, odorless gas. Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nausea. If you have these signs, the heater may not be operating or venting properly. Get fresh air at once! Have heater or heater venting system serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, persons with heart and lung disease and anemia, those under the influence of alcohol, and those at high altitudes.

14

100748

Image 14
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualFor Your Safety Contents Electrical shock, and carbon monoxide poisoning SafetyInformation Carbon monoxide poisoning may lead to deathSafety Information Product IdentificationLocal Codes FeaturesInstalling Heater UnpackingInstalling Heater Locating HeaterVenting Heater Venting Heater Do not vent heater in any of the following ways see FigureVenting Heater Proper Size Vent Qualified service person must connect heater to gas InstallingConnecting to GAS Supply Supply. Follow all local codesGas Connection Ing or servicing. Correct all leaks at once Test all gas piping and connections for leaks after installChecking GAS Connections Fresh AIR for Combustion and Ventilation Determining FRESH-AIR Flow for Heater Location CombustionVentilation Draft Hood Spillage TestFresh AIR for Ventilation Air from OutdoorsConfined area has an air volume of less than 50 cubic 15 to make sure fresh air ventilation is adequateLighting Instructions For Your Safety Read Before LightingOperating Heater Viewing Pilot To Turn OFF GAS to Appliance Manual Lighting ProcedureBlower Operation Shutting Off HeaterBurner Flame Pattern Inspecting Pilot and Burner FlamePilot Flame Pattern Correct Burner Flame Pattern Cleaning MaintenanceShutoff valve before servicing. Only a qualified service Trouble ShootingUnless you need gas supply for testing, shut off manual Turn off and unplug heater and let cool before servicingProblem Cause TroubleObserved Possible Problem Cause Remedy TROUBLE- ShootingStatement at top Connections,Service Procedures Removing Control Valve and Burner TubeRemoving Burner Blower WiringDiagram Changing Burner OrificeTechnical ServiceAccessories HintsParts Not Under Warranty Ordering ReplacementParts Under Warranty PartsIllustrated Parts List Cabinet AssemblyBurner Assembly Parts List Warranty Information Limited Warranty Vanguard Vented Propane GAS Heaters

GVC50PA, GVC35PA, GVC65PA specifications

The Desa GVC65PA, GVC35PA, and GVC50PA are advanced gas-fired ventless fireplaces that are designed to deliver efficiency, convenience, and aesthetic appeal. These models are particularly popular in modern homes for their ability to provide warmth without the burdens of traditional venting systems.

The GVC65PA stands out for its powerful heating capacity, making it ideal for larger spaces. It boasts a maximum output of 65,000 BTUs, ensuring that even the coldest rooms can be comfortably heated. This model is equipped with an innovative digital thermostat, allowing users to maintain their desired temperature with precision. Its remote control feature adds convenience, enabling homeowners to adjust settings from across the room.

The GVC35PA, on the other hand, is tailored for smaller spaces and is perfect for those looking for warmth in a compact format. With a maximum output of 35,000 BTUs, it efficiently heats rooms without overwhelming them. This model features a sleek design with a front access panel for easy maintenance. Its variable flame height control adds to its appeal, allowing users to customize the ambiance of their living space.

For those desiring a mid-range option, the GVC50PA is a versatile choice. With an output of 50,000 BTUs, it strikes a balance between capacity and efficiency, making it suitable for diverse room sizes. This model incorporates advanced safety features, such as an oxygen depletion sensor that automatically shuts off the unit if oxygen levels drop too low, providing peace of mind for users.

All three models are equipped with ceramic fiber logs that replicate the appearance of real wood, enhancing the visual aesthetics of the fireplace. These fireplaces utilize advanced burner technology, ensuring even heat distribution and maximizing fuel efficiency. The ventless design means that they can be installed in virtually any room without the need for complex venting systems, making them a practical choice for homeowners.

In summary, the Desa GVC65PA, GVC35PA, and GVC50PA represent the pinnacle of modern ventless fireplace technology. They offer a combination of aesthetic charm, powerful heating capabilities, and safety features, making them an attractive addition to any home. With their ease of installation and operation, these fireplaces are an excellent option for anyone seeking cozy warmth in a stylish package.