Desa GVC35PA Operating Heater, For Your Safety Read Before Lighting, Lighting Instructions

Page 18

18

OPERATING HEATER

WARNING

Heater and venting system surfaces are very hot during operation. Keep children and adults away from hot sur- faces to avoid burns and clothing ignition. Carefully super- vise young children when they are in the same room as heater. Heater will remain hot for a time after shut down. Let surface cool before touching.

NOTICE

If operating heater for the first time, a slight odor will occur. This odor will go away after a few hours of operation.

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING

If you do not follow these instructions exactly, a fire or explosion may result causing property damage, per- sonal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above.

2.If heater is equipped with a blower, turn off all electric power to the heater.

3.Make sure manual shutoff valve is fully open.

4.Locate control knob on top of heater. Fully depress control knob in any position other than PILOT to shut off burner and pilot.

DEPRESS

Ignitor Button

FOR OFF

PILOT

APPUYER POUR

ARRÊ TER

VEILLEUSE

LOW

HIGH

BAS

HAUT

Control Knob

Figure 12 - Control Knob and Ignitor Button

100748

Image 18
Contents OWNER’S Operation and Installation Manual For Your SafetyWhat to do if YOU Smell GAS Contents Electrical shock, and carbon monoxide poisoning SafetyInformation Carbon monoxide poisoning may lead to deathSafety Information Product IdentificationLocal Codes FeaturesInstalling Heater UnpackingInstalling Heater Locating HeaterVenting Heater Venting Heater Do not vent heater in any of the following ways see FigureVenting Heater Proper Size Vent Qualified service person must connect heater to gas InstallingConnecting to GAS Supply Supply. Follow all local codesGas Connection Test all gas piping and connections for leaks after install Checking GAS ConnectionsIng or servicing. Correct all leaks at once Fresh AIR for Combustion and Ventilation Determining FRESH-AIR Flow for Heater Location CombustionVentilation Draft Hood Spillage TestFresh AIR for Ventilation Air from OutdoorsConfined area has an air volume of less than 50 cubic 15 to make sure fresh air ventilation is adequateFor Your Safety Read Before Lighting Operating HeaterLighting Instructions Viewing Pilot To Turn OFF GAS to Appliance Manual Lighting ProcedureBlower Operation Shutting Off HeaterInspecting Pilot and Burner Flame Pilot Flame PatternBurner Flame Pattern Correct Burner Flame Pattern Cleaning MaintenanceShutoff valve before servicing. Only a qualified service Trouble ShootingUnless you need gas supply for testing, shut off manual Turn off and unplug heater and let cool before servicingProblem Cause TroubleObserved Possible Problem Cause Remedy TROUBLE- ShootingStatement at top Connections,Service Procedures Removing Control Valve and Burner TubeRemoving Burner Blower WiringDiagram Changing Burner OrificeTechnical ServiceAccessories HintsParts Not Under Warranty Ordering ReplacementParts Under Warranty PartsIllustrated Parts List Cabinet AssemblyBurner Assembly Parts List Warranty Information Limited Warranty Vanguard Vented Propane GAS Heaters

GVC50PA, GVC35PA, GVC65PA specifications

The Desa GVC65PA, GVC35PA, and GVC50PA are advanced gas-fired ventless fireplaces that are designed to deliver efficiency, convenience, and aesthetic appeal. These models are particularly popular in modern homes for their ability to provide warmth without the burdens of traditional venting systems.

The GVC65PA stands out for its powerful heating capacity, making it ideal for larger spaces. It boasts a maximum output of 65,000 BTUs, ensuring that even the coldest rooms can be comfortably heated. This model is equipped with an innovative digital thermostat, allowing users to maintain their desired temperature with precision. Its remote control feature adds convenience, enabling homeowners to adjust settings from across the room.

The GVC35PA, on the other hand, is tailored for smaller spaces and is perfect for those looking for warmth in a compact format. With a maximum output of 35,000 BTUs, it efficiently heats rooms without overwhelming them. This model features a sleek design with a front access panel for easy maintenance. Its variable flame height control adds to its appeal, allowing users to customize the ambiance of their living space.

For those desiring a mid-range option, the GVC50PA is a versatile choice. With an output of 50,000 BTUs, it strikes a balance between capacity and efficiency, making it suitable for diverse room sizes. This model incorporates advanced safety features, such as an oxygen depletion sensor that automatically shuts off the unit if oxygen levels drop too low, providing peace of mind for users.

All three models are equipped with ceramic fiber logs that replicate the appearance of real wood, enhancing the visual aesthetics of the fireplace. These fireplaces utilize advanced burner technology, ensuring even heat distribution and maximizing fuel efficiency. The ventless design means that they can be installed in virtually any room without the need for complex venting systems, making them a practical choice for homeowners.

In summary, the Desa GVC65PA, GVC35PA, and GVC50PA represent the pinnacle of modern ventless fireplace technology. They offer a combination of aesthetic charm, powerful heating capabilities, and safety features, making them an attractive addition to any home. With their ease of installation and operation, these fireplaces are an excellent option for anyone seeking cozy warmth in a stylish package.