Desa GVC50PA, GVC35PA, GVC65PA installation manual Safety Information

Page 4

SAFETY INFORMATION

Continued

WARNINGS Continued

7.Provide the following minimum heater clearances from combustibles (as viewed from the front of heater):

Front: 48 inches

Back: 6 inches

Top: 53 inches

Right Side: 12 inches

Left Side: 6 inches

8.Do not run heater

where flammable liquids or vapors are used or stored

under dusty conditions

9.Never place clothing or any flammable objects on the heater or venting system.

10.Heater and venting system surfaces are very hot during operation. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Carefully supervise young children when they are in the same room as heater. Heater will remain hot for a time after shutdown. Let surface cool before touching.

11.Do not use heater as a cooking device.

12.Do not alter heater or its controls. Any change may create a safety hazard.

13.Turn off heater and unplug (if equipped with blower) and let cool before servicing. Unless you need gas supply for testing, shut off manual shutoff valve before servicing. Only a qualified service person should service and repair heater and venting system.

14.Replace any safety screen or guard removed for servicing before running heater.

15.Do not use heater if any part has been under water. Immediately call a qualified service person to inspect the heater and to replace any part of the control system and any gas control which has been under water.

4

100748

Image 4 Contents
For Your Safety OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS Contents Safety InformationElectrical shock, and carbon monoxide poisoning Carbon monoxide poisoning may lead to deathSafety Information Product IdentificationFeatures Installing HeaterLocal Codes UnpackingInstalling Heater Locating HeaterVenting Heater Venting Heater Do not vent heater in any of the following ways see FigureVenting Heater Proper Size Vent Installing Connecting to GAS SupplyQualified service person must connect heater to gas Supply. Follow all local codesGas Connection Checking GAS Connections Test all gas piping and connections for leaks after installIng or servicing. Correct all leaks at once Fresh AIR for Combustion and Ventilation Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Draft Hood Spillage TestFresh AIR for Ventilation Air from OutdoorsConfined area has an air volume of less than 50 cubic 15 to make sure fresh air ventilation is adequateOperating Heater For Your Safety Read Before LightingLighting Instructions Viewing Pilot Manual Lighting Procedure Blower OperationTo Turn OFF GAS to Appliance Shutting Off HeaterPilot Flame Pattern Inspecting Pilot and Burner FlameBurner Flame Pattern Correct Burner Flame Pattern Cleaning MaintenanceTrouble Shooting Unless you need gas supply for testing, shut off manualShutoff valve before servicing. Only a qualified service Turn off and unplug heater and let cool before servicingProblem Cause TroubleObserved Possible Problem Cause Remedy TROUBLE- ShootingStatement at top Connections,Service Procedures Removing Control Valve and Burner TubeRemoving Burner Wiring DiagramBlower Changing Burner OrificeService AccessoriesTechnical HintsOrdering Replacement Parts Under WarrantyParts Not Under Warranty PartsIllustrated Parts List Cabinet AssemblyBurner Assembly Parts List Warranty Information Limited Warranty Vanguard Vented Propane GAS Heaters