Desa GVC50PA, GVC35PA Checking GAS Connections, Ing or servicing. Correct all leaks at once

Page 13

INSTALLING

CHECKING GAS CONNECTIONS

HEATER

 

WARNING

Continued

 

Test all gas piping and connections for leaks after install-

 

 

ing or servicing. Correct all leaks at once.

 

 

 

WARNING

Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

CAUTION

Make sure external regulator has been installed be- tween propane supply and heater. See guidelines under Connecting to Gas Supply, page 11.

Pressure Testing Gas Supply Piping System

Test Pressures In Excess of 1/2 PSIG

1.Disconnect heater and its individual manual shutoff valve from gas supply pipe. Pressures in excess of 1/2 PSIG will damage heater regulator.

2.Cap off open end of gas pipe where manual shutoff valve was connected.

3.Pressurize supply piping system by either using compressed air or opening propane supply tank valve.

4.Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

Test Pressures Equal To or Less Than 1/2 PSIG

1.Close manual shutoff valve (see Figure 8).

2.Pressurize supply piping system by either using compressed air or opening propane supply tank valve.

3.Check all joints from propane supply tank to manual shutoff valve. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

Pressure Testing Heater Gas Connections

1.Open manual shutoff valve (see Figure 8).

2.Open propane supply tank valve.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from manual shutoff valve to control valve on heater. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light heater (see Operating Heater, pages 18 through 20). Check the rest of the internal joints for leaks.

7.Turn off heater (see To Turn Off Gas to Appliance, page 20).

PO On Position

Off Position

Figure 8 - Manual Shutoff Valve

13

100748

Image 13
Contents For Your Safety OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS Contents Information SafetyElectrical shock, and carbon monoxide poisoning Carbon monoxide poisoning may lead to deathSafety Information Identification ProductInstalling Heater FeaturesLocal Codes UnpackingLocating Heater Installing HeaterVenting Heater Do not vent heater in any of the following ways see Figure Venting HeaterVenting Heater Proper Size Vent Connecting to GAS Supply InstallingQualified service person must connect heater to gas Supply. Follow all local codesGas Connection Checking GAS Connections Test all gas piping and connections for leaks after installIng or servicing. Correct all leaks at once Fresh AIR for Combustion and Ventilation Ventilation CombustionDetermining FRESH-AIR Flow for Heater Location Draft Hood Spillage TestVentilation Air from Outdoors Fresh AIR for15 to make sure fresh air ventilation is adequate Confined area has an air volume of less than 50 cubicOperating Heater For Your Safety Read Before LightingLighting Instructions Viewing Pilot Blower Operation Manual Lighting ProcedureTo Turn OFF GAS to Appliance Shutting Off HeaterPilot Flame Pattern Inspecting Pilot and Burner FlameBurner Flame Pattern Correct Burner Flame Pattern Maintenance CleaningUnless you need gas supply for testing, shut off manual Trouble ShootingShutoff valve before servicing. Only a qualified service Turn off and unplug heater and let cool before servicingTrouble Problem CauseTROUBLE- Shooting Observed Possible Problem Cause RemedyConnections, Statement at topRemoving Control Valve and Burner Tube Service ProceduresRemoving Burner Diagram WiringBlower Changing Burner OrificeAccessories ServiceTechnical HintsParts Under Warranty Ordering ReplacementParts Not Under Warranty PartsCabinet Assembly Illustrated Parts ListBurner Assembly Parts List Limited Warranty Vanguard Vented Propane GAS Heaters Warranty Information

GVC50PA, GVC35PA, GVC65PA specifications

The Desa GVC65PA, GVC35PA, and GVC50PA are advanced gas-fired ventless fireplaces that are designed to deliver efficiency, convenience, and aesthetic appeal. These models are particularly popular in modern homes for their ability to provide warmth without the burdens of traditional venting systems.

The GVC65PA stands out for its powerful heating capacity, making it ideal for larger spaces. It boasts a maximum output of 65,000 BTUs, ensuring that even the coldest rooms can be comfortably heated. This model is equipped with an innovative digital thermostat, allowing users to maintain their desired temperature with precision. Its remote control feature adds convenience, enabling homeowners to adjust settings from across the room.

The GVC35PA, on the other hand, is tailored for smaller spaces and is perfect for those looking for warmth in a compact format. With a maximum output of 35,000 BTUs, it efficiently heats rooms without overwhelming them. This model features a sleek design with a front access panel for easy maintenance. Its variable flame height control adds to its appeal, allowing users to customize the ambiance of their living space.

For those desiring a mid-range option, the GVC50PA is a versatile choice. With an output of 50,000 BTUs, it strikes a balance between capacity and efficiency, making it suitable for diverse room sizes. This model incorporates advanced safety features, such as an oxygen depletion sensor that automatically shuts off the unit if oxygen levels drop too low, providing peace of mind for users.

All three models are equipped with ceramic fiber logs that replicate the appearance of real wood, enhancing the visual aesthetics of the fireplace. These fireplaces utilize advanced burner technology, ensuring even heat distribution and maximizing fuel efficiency. The ventless design means that they can be installed in virtually any room without the need for complex venting systems, making them a practical choice for homeowners.

In summary, the Desa GVC65PA, GVC35PA, and GVC50PA represent the pinnacle of modern ventless fireplace technology. They offer a combination of aesthetic charm, powerful heating capabilities, and safety features, making them an attractive addition to any home. With their ease of installation and operation, these fireplaces are an excellent option for anyone seeking cozy warmth in a stylish package.