Desa GVC65PA, GVC35PA, GVC50PA installation manual Contents

Page 2

2

CONTENTS

SECTION

PAGE

Safety Information

3

Product Identification

5

Local Codes

6

Unpacking

6

Product Features

6

Installing Heater

6

Check Gas Type

6

Installation Items

6

Locating Heater

7

Venting Heater

8

Connecting to Gas Supply

11

Checking Gas Connections

13

Fresh Air For Combustion and Ventilation

14

Determining Fresh-Air Flow for Heater Location

 

Example 1: Locating Heater in Unconfined (Open) Area 15

Draft Hood Spillage Test

15

Providing Permanent Fresh-Air Ventilation

16

Example 2: Locating Heater in Confined (Closed) Area ..

17

Ventilating Confined Area

17

Operating Heater

18

For Your Safety Read Before Lighting

18

Lighting Instructions

18

Manual Lighting Procedure

20

Blower Operation (For Models with Blower)

20

To Turn Off Gas To Appliance

20

Inspecting Pilot and Burner Flame

21

Pilot Flame Pattern

21

Burner Flame Pattern

21

Cleaning and Maintenance

23

Troubleshooting

24

Service Procedures

28

Removing Control Valve and Burner Tube

28

Removing Burner

29

Changing Burner Orifice

30

Blower Wiring Diagram

30

Technical Service

31

Specifications

31

Service Hints

31

Accessories

31

Ordering Replacement Parts

32

Parts Centrals

32

Illustrated Parts List

33-35

Warranty Information

Back Cover

100748

Image 2
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualFor Your Safety Contents Electrical shock, and carbon monoxide poisoning SafetyInformation Carbon monoxide poisoning may lead to deathSafety Information Product IdentificationLocal Codes FeaturesInstalling Heater UnpackingInstalling Heater Locating HeaterVenting Heater Venting Heater Do not vent heater in any of the following ways see FigureVenting Heater Proper Size Vent Qualified service person must connect heater to gas InstallingConnecting to GAS Supply Supply. Follow all local codesGas Connection Ing or servicing. Correct all leaks at once Test all gas piping and connections for leaks after installChecking GAS Connections Fresh AIR for Combustion and Ventilation Determining FRESH-AIR Flow for Heater Location CombustionVentilation Draft Hood Spillage TestFresh AIR for Ventilation Air from OutdoorsConfined area has an air volume of less than 50 cubic 15 to make sure fresh air ventilation is adequateLighting Instructions For Your Safety Read Before LightingOperating Heater Viewing Pilot To Turn OFF GAS to Appliance Manual Lighting ProcedureBlower Operation Shutting Off HeaterBurner Flame Pattern Inspecting Pilot and Burner FlamePilot Flame Pattern Correct Burner Flame Pattern Cleaning MaintenanceShutoff valve before servicing. Only a qualified service Trouble ShootingUnless you need gas supply for testing, shut off manual Turn off and unplug heater and let cool before servicingProblem Cause TroubleObserved Possible Problem Cause Remedy TROUBLE- ShootingStatement at top Connections,Service Procedures Removing Control Valve and Burner TubeRemoving Burner Blower WiringDiagram Changing Burner OrificeTechnical ServiceAccessories HintsParts Not Under Warranty Ordering ReplacementParts Under Warranty PartsIllustrated Parts List Cabinet AssemblyBurner Assembly Parts List Warranty Information Limited Warranty Vanguard Vented Propane GAS Heaters

GVC50PA, GVC35PA, GVC65PA specifications

The Desa GVC65PA, GVC35PA, and GVC50PA are advanced gas-fired ventless fireplaces that are designed to deliver efficiency, convenience, and aesthetic appeal. These models are particularly popular in modern homes for their ability to provide warmth without the burdens of traditional venting systems.

The GVC65PA stands out for its powerful heating capacity, making it ideal for larger spaces. It boasts a maximum output of 65,000 BTUs, ensuring that even the coldest rooms can be comfortably heated. This model is equipped with an innovative digital thermostat, allowing users to maintain their desired temperature with precision. Its remote control feature adds convenience, enabling homeowners to adjust settings from across the room.

The GVC35PA, on the other hand, is tailored for smaller spaces and is perfect for those looking for warmth in a compact format. With a maximum output of 35,000 BTUs, it efficiently heats rooms without overwhelming them. This model features a sleek design with a front access panel for easy maintenance. Its variable flame height control adds to its appeal, allowing users to customize the ambiance of their living space.

For those desiring a mid-range option, the GVC50PA is a versatile choice. With an output of 50,000 BTUs, it strikes a balance between capacity and efficiency, making it suitable for diverse room sizes. This model incorporates advanced safety features, such as an oxygen depletion sensor that automatically shuts off the unit if oxygen levels drop too low, providing peace of mind for users.

All three models are equipped with ceramic fiber logs that replicate the appearance of real wood, enhancing the visual aesthetics of the fireplace. These fireplaces utilize advanced burner technology, ensuring even heat distribution and maximizing fuel efficiency. The ventless design means that they can be installed in virtually any room without the need for complex venting systems, making them a practical choice for homeowners.

In summary, the Desa GVC65PA, GVC35PA, and GVC50PA represent the pinnacle of modern ventless fireplace technology. They offer a combination of aesthetic charm, powerful heating capabilities, and safety features, making them an attractive addition to any home. With their ease of installation and operation, these fireplaces are an excellent option for anyone seeking cozy warmth in a stylish package.