Desa RCLP50VA owner manual Parts List, KEY Part Description QTY

Page 11

OWNER’S MANUAL

PARTS LIST

RCLP50VA

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 12 of this manual.

KEY

PART

 

 

NO.

NO.

DESCRIPTION

QTY.

 

 

 

 

1

104154-01

Combustion Chamber

1

2

M11084-26

Hex Tap Screw, #10-16 x 3/8"

7

3

105333-01

Outer Shell

1

4

104786-01

Handle Kit

1

5

M11143-1

Bushing, Strain Relief

1

6

101480-12

Wire Assembly

1

7

M11084-27

Hex Tap Screw, #12-14 x 1/2"

3

8

099393-03

Knob, Control

1

9

105341-01

Burner Assembly

1

10

099539-01

Electrode Ignitor

1

11

M11084-38

Hex Tap Screw, #8-18 x 3/8"

1

12

101478-03

Fan

1

13

105332-01

Motor

1

14

103863-01

Fan Guard

1

15

097384-02

Captive Washer Nut

3

16

097968-05

Hex Screw, #4-40 x 1/2"

2

17

NPC-00C

Hex Nut, #4-40

2

18

101481-04

Thermal Switch

1

19

097776-01

Universal Bushing

1

20

099237-01

Thermocouple Nut

2

21

104146-01

Thermocouple

1

22

103921-01

Valve/Orifice Assembly

1

23

102445-01

Piezo Ignitor

1

24

078978-03

Sleeve Cap

1

25

105335-01

Base Assembly

1

26

099202-02

Steel Rivet, 1/8"

1

27

M12461-25

Hex Screw, 8-32 x 3/8

2

28

098219-17

Cord, Power Supply

1

 

 

 

 

PARTS AVAILABLE - NOT SHOWN

 

097941-30

Tradename Decal

2

 

103867-04

General Information Decal

1

 

103869-04

Operation Decal

1

 

079663-01

LP Warning Decal (English)

1

 

079663-02

LP Warning Decal (French)

1

 

099672-02

Notice Decal

1

 

 

 

 

 

 

ACCESSORIES

 

 

 

 

 

 

LPA3055

Regulator & Hose Assembly

1

 

LPA4020

Fuel Gas Connector

1

 

 

 

 

105339

11

Image 11
Contents Variable Canadian Propane Construction HeaterPropane Construction Heater Safety InformationPropane Supply Product IdentificationUnpacking Theory Operation AssemblyVentilation InstallationTo Stop Heater Extension Cord Wire Size RequirementsStorage To Start HeaterDo not block the flow of com- bustion or ventilation air MaintenanceTroubleshooting Observed Fault Possible Cause RemedyMotor Service ProceduresElectrical System Ignitor FANRCLP50VA Illustrated Parts BreakdownKEY Part Description QTY Parts ListParts Under Warranty SpecificationsReplacement Parts Accessories105339 Repair Service Warranty ServiceManuel D’UTILISATION Avertissements Informations Concernant LA SécuritéNombre de DéballageAlimentation EN Propane Identification DU ProduitAIR Forcé Principe DE FonctionnementAssemblage Alimentation EN CombustiblePositionnement du détendeur Remise EN Marche FonctionnementMise EN Marche Arrêt DE L’APPAREILEntretien RemisageProblème Cause Possible Remède DépannageMoteur Procédures ’ENTRETIENCircuit Électrique Allumeur VentilateurPièces Sous Garantie AccessoiresCaractéristiques Pièces DétachéesVUE Éclatée DES Pièces Pièce DE RÉF Description QTÉ Liste DES PiècesRéparations Sous Garantie Service DE RéparationsConserver Cette Garantie Garantie Limitée

RCLP50VA specifications

Desa RCLP50VA is an innovative and efficient heating solution designed to meet the modern demands of both residential and commercial environments. This model stands out due to its advanced technology and user-friendly features, making it a preferred choice for heating needs.

One of the most prominent features of the Desa RCLP50VA is its high-efficiency performance. It utilizes state-of-the-art combustion technology to deliver robust heating output while minimizing energy consumption. This efficiency not only reduces utility bills but also contributes to a more sustainable energy footprint, aligning with the growing demand for environmentally responsible appliances.

The unit is powered by liquid propane, which ensures consistent and reliable heat during cold weather conditions. Its versatile design allows it to be installed in various settings, providing users with flexibility in heating larger spaces. The heating capacity of the Desa RCLP50VA is substantial, making it suitable for workshops, garages, and even larger residential areas.

Another key characteristic of the RCLP50VA is its safety features. It includes an automatic shut-off function that activates in case of overheating or other malfunctions. This feature provides peace of mind to users, ensuring safe operation even in busy environments. Additionally, it is equipped with a built-in oxygen depletion sensor, which monitors air quality and halts operation if harmful levels of carbon monoxide are detected.

The construction of the Desa RCLP50VA emphasizes durability and longevity. It boasts a rugged exterior designed to withstand the rigors of both industrial and residential use. The materials employed are resistant to corrosion, ensuring the unit maintains its performance over time.

The user interface of the RCLP50VA is straightforward, with an easy-to-read control panel that allows users to adjust temperature settings and monitor operational status. This intuitive design eliminates confusion, making it accessible for all users, regardless of their technical expertise.

In conclusion, the Desa RCLP50VA is a top-tier heating solution characterized by its efficiency, safety features, and user-friendly design. Its advanced technologies and robust construction make it an ideal choice for anyone looking to invest in a reliable and effective heating system that meets the demands of today’s energy-conscious consumers.