FOR YOUR SAFETY READ BEFORE LIGHTING

This appliance needs fresh air for safe operation

 

 

 

adequate combustion and ventilation air.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and must be installed so there are provisions for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARNING:￿

If you do not follow these instructions exactly, a

 

 

 

 

This appliance must be installed in accordance with

 

 

 

 

 

 

 

fire or explosion may result causing property

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

local codes, if any; if not, follow ANSI Z223.1 or, in

 

 

 

 

 

 

 

damage, personal injury or loss of life.

 

 

 

 

Canada, current CAN/CGA-B149.

 

 

 

 

 

 

 

 

 

 

 

A.￿

This appliance is equipped with an ignition device which

￿

•￿ If you cannot reach your gas supplier, call the fire

This appliance must be properly connected to a

 

 

 

automatically lights the pilot. DO NOT try to light the pilot by

 

department.

 

 

 

 

venting system in accordance with the

 

 

 

hand.

 

C.￿

Use only your hand to turn the gas control knob. Never use

manufacturer's installation instructions.

 

 

B.￿

BEFORE LIGHTING smell all around the appliance area for

 

 

 

 

 

WARNING: Improper installation,

 

 

 

tools. If the lever or knob will not move by hand, don't try to

 

 

 

gas. Be sure to smell next to the floor because some gas is

 

 

 

 

heavier than air and will settle on the floor.

 

 

repair it, call a qualified service technician. Force or

adjustment, alteration, service or maintenance can

 

 

 

 

 

attempted repair may result in a fire or explosion.

 

 

￿

WHAT TO DO IF YOU SMELL GAS

 

 

cause injury or property damage. Refer to the

 

 

 

D.￿

Do not use this appliance if any part has been under water.

 

 

￿

•￿ Do not try to light any appliance.

 

owner's information manual provided with the

Quadra-

 

 

Immediately call a qualified service technician to inspect the

￿

•￿ Do not touch any electric switch; do not use any phone in

 

appliance and to replace any part of the control system and

appliance. For assistance or additional information

 

 

 

your building.

 

 

any gas control which has been under water.

consult a qualified installer, service agency or the

Fire

￿ •￿ Immediately call your gas supplier from a neighbor's

 

 

 

 

 

 

gas supplier.

 

phone. Follow the gas supplier's instructions.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION: Hot while in operation. Do not touch.

•QFP38

 

 

 

 

LIGHTING INSTRUCTIONS

 

 

 

 

 

 

 

 

 

 

 

 

Keep children, clothing, furniture, gasoline and other liquids

Series•

 

 

 

 

 

 

 

 

 

 

 

 

having flammable vapors away.

2.￿

Turn OFF the gas supply to the appliance.

 

 

don't smell gas, go to the next step.

 

 

 

 

 

 

 

 

 

 

WARNING RISK OF FIRE

 

 

1.￿ STOP! Read the safety information above on this label.

 

STOP! Follow "B" in the safety information above on this label. If you

 

 

 

4061

 

3.￿

Turn OFF all electric power to the appliance.

6.￿

To turn on the burner, turn on all electric power to this appliance and

This appliance is intended to burn a specified gas fuel only. Do

 

4.￿

This appliance is equipped with an ignition device which

 

turn on the gas supply.

 

 

 

 

-

 

 

automatically lights the pilot. DO NOT try to light the pilot

7.￿

Press the “ON/OFF” key on the transmitter.

 

 

not attempt to use with solid wood fuel or another type of fuel.

300

 

 

 

 

Do not attempt to modify or use any other type of gas burner

 

 

by hand.

 

8.￿

If the appliance will not operate, follow the instructions "TO TURN OFF

Rev

 

 

system.

5.￿

Wait five minutes to clear out any gas. If you then smell gas,

 

GAS TO APPLIANCE" and call your service technician or gas supplier.

i •

 

 

TO TURN OFF GAS TO APPLIANCE

 

WARNING: Disconnect the electric power before

9/09

 

 

 

 

 

 

 

 

 

 

 

 

appliance must be replaced, it must be replaced with 105° C or its

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

servicing. If for any reason the original wire supplied with the

 

 

1.￿ Press “ON/OFF” key on the transmitter.

 

 

 

 

 

 

 

equivalent.

 

 

2.￿ Turn OFF all electric power to the appliance if service is to be

 

 

 

 

 

 

 

 

 

 

 

 

performed.

 

 

Gas Supply

Gas Supply

 

 

 

 

 

3.￿ Turn gas supply OFF.

 

 

Closed (OFF)

Open (ON)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*￿Also certified for installation in a bedroom or a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

bed-sitting room.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*￿For U.S. only!

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Due to high surface temperatures, keep children, clothing and furniture away.

 

 

 

 

 

 

NATURAL GAS

 

 

 

Keep burner and control compartment clean. See installation and operating instructions accompanying the appliance.

4061-309a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• • •

Q

If your fireplace must be deactivated for serviced or an

The IPI system may be operated with four AA batteries

For normal use, activate/deactivate your fireplace with

. Lighting Instructions (IPI)

extended period of

.

the remote control.

 

time, follow the instructions below.

 

 

 

Image 20
Contents Installation and Operation ModelsModel Number Serial Number CongratulationsHomeowner Reference Information Table of Contents Appliance Setup = Contains updated informationLimited Lifetime Warranty Limited Lifetime Warranty Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Your Fireplace Gas Fireplace SafetyOperating Instructions Fixed Glass Assembly Remote ControlsClear Space Decorative Doors and FrontsAUX Outlet Plug Accent Lighting System DescriptionFan Control Module PRG Key PIN terminal Positions Slider ReceiverInitializing the System for the First Time Transmitter Remote Control with LCD Display Operating Procedure with Split Flow dual burner control Turn off the Appliance Temperature Indication DisplayTurn on the Appliance Remote Flame Control 11 Remote Flame ControlRoom Thermostat Transmitter Option Smart Thermostat Transmitter OperationFan Speed Control Remote Actuated 120V Auxiliary Outlet accent lightingLow Battery Power Detection Manual Bypass of the Remote SystemRemote Operation Key LockFor Your Safety Read Before Lighting Lighting Instructions IPIFrequently Asked Questions Initial Break-in ProcedureAfter Fireplace is Lit This cures the materials used to manufacture the fire- placeMaintenance and Service Maintenance Tasks-HomeownerMaintenance Tasks-Qualified Service Technician Fan Replacement & Maintenance Bend Down TabRemove Wing nuts Both sides Getting Started Typical Appliance SystemInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Framing and Clearances Select Appliance LocationConstruct the Appliance Chase ClearancesMantel Legs or Wall Projections Mantel and Wall ProjectionsMantels Gas, Wood or Fuel Oil Termination Cap Termination LocationsVent Termination Minimum Clearances Minimum Clearances for Termination Vent Information and Diagrams Approved PipeVent Table Key Use of ElbowsOne Elbow Vent DiagramsTop Vent Horizontal Termination Two 45 Elbows replacing One 90 Elbow Two ElbowsTop Vent Vertical Termination No ElbowVent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Non-Combustible Wall PenetrationInstall the Ceiling Firestop Ceiling firestop Must be used between floors and atticsVaulted Ceiling Installation Install Attic Insulation ShieldFlat Ceiling Installation Secure and Level the Appliance Intake Adapter AssemblyAppliance Preparation Install Vent Pipe Attach Pipe to the Firebox AssemblyAssemble Vent Sections Assemble Pipe SectionsAssemble Slip Sections Slip Section Pilot HolesSecure the Vent Sections Disassemble Vent SectionsInstall Metal Roof Flashing CaulkAssemble and Install Storm Collar 13 Assembling the Storm CollarInstall Vertical Termination Cap Heat Shield Requirements for Horizontal TerminationInstall Horizontal Termination Cap Failure to maintain overlap may cause overheating and fireShrouds HHT ShroudsField Constructed Shrouds Open Top Shroud may be used with DVP-TV, DVP-TVHW, SLP-TVHWMailbox Style Shroud Dimensions Min. Base Dims Gas Connection Gas InformationGas Pressure Wiring Requirements Technical DataIntellifire Ignition System Wiring Electrical InformationIPI Module 4 from Sleeve Heat-Zone-Gas Junction Box InstallationInstall the Heat Zone Kit before enclosing the appliance 43 3/8 FinishingFacing Material Doors Recessed Fit Facing Template RemovalDoors Outside Surface Fit Minimum Vertical and Maximum Horizontal Dimensions Appliance Setup Remove Fixed Glass AssemblyClean the Appliance Install the RefractoryInstall Logs, Ember Bed Log Bracket is Pre-set for NG or LPOverall placement of the first eight logs is shown in Figure Install Andirons, Lava Rock, Rockwool Complete Log InstallationAccent Lighting Set Up ScrewsAdjust the Air Shutter Adjust the Vertical BaffleReplacing Fixed Glass Assembly Install Door FrontsRemoving Fixed Glass Assembly Troubleshooting TroubleshootingThis Opening Appliance Dimension Diagram Reference MaterialsVent Components Diagrams DVP Vent ComponentsDVP-TRAPFL DVP-HPC DVP-TRAP Service Parts QFP38-NG, QFP38-LPAt Depot Log Set Assembly Log 1 Back Log 4061-170 Ember BedStocked Light Assembly Valve Assembly Valve Assembly NG Optional Components 7571 215th Street West, Lakeville, MN Contact InformationQuadra-Fire, a brand of Hearth & Home Technologies Inc

QFP38-NG, QFP38-LP specifications

The Quadra-Fire QFP38-NG and QFP38-LP are high-performance gas fireplaces designed to deliver both warmth and aesthetic appeal to homes. These models are known for their advanced features, reliable technologies, and user-friendly characteristics, making them ideal choices for homeowners looking to enhance their living spaces.

One of the key features of the QFP38 series is its efficient heating capability. With impressive BTU output, both the QFP38-NG (natural gas) and QFP38-LP (liquid propane) models provide ample warmth, making them suitable for various room sizes. They utilize a powerful burner system that maximizes combustion efficiency, thereby delivering consistent heat while minimizing fuel consumption.

The QFP38 series is designed with a contemporary and elegant appearance, featuring a large viewing area that showcases the mesmerizing flame. The clean, modern lines and glass front make it an eye-catching centerpiece in any room. Additionally, these fireplaces come with customizable options, allowing homeowners to choose from different interior styles, including log sets and decorative fire glass, to match their decor preferences.

Another standout technology in these models is the advanced control system. The QFP38 series is compatible with remote control operation, enabling users to adjust the flames and heat settings from the comfort of their seating area. This feature enhances convenience, allowing homeowners to set the desired ambiance and warmth with ease.

Safety is a paramount concern, and the QFP38 fireplaces are equipped with several safety features. These include a built-in oxygen depletion sensor that automatically shuts off the gas supply in case of insufficient oxygen levels. Additionally, the sealed combustion design prevents indoor air contamination, providing peace of mind to users.

The installation process of the QFP38-NG and QFP38-LP is straightforward, thanks to their venting options that accommodate various home layouts. Both models are designed to be versatile, with horizontal and vertical venting capabilities, offering greater flexibility for installation.

In terms of maintenance, the QFP38 series is user-friendly, requiring minimal upkeep to ensure optimal performance. Regular cleaning and inspection of the glass and burner components are typically all that is needed to maintain the fireplace's efficiency and aesthetic appeal.

Overall, the Quadra-Fire QFP38-NG and QFP38-LP gas fireplaces combine cutting-edge technology, modern design, and safety features, making them excellent options for anyone looking to add warmth and style to their home. Whether used as a primary heat source or as an elegant focal point, these models are sure to enhance any living space.