Quadra-Fire QFP38-LP, QFP38-NG owner manual Remove Wing nuts Both sides

Page 25

Remove two wing nuts holding the fan bracket in place and remove bracket.

Remove

Wing nuts

(both sides)

Figure 3.7 Remove Fan Bracket

Remove fan through the valve plate opening.

Figure 3.8 Remove Fan

Clean or replace fan.

Check condition of gasket. It should remain in place when you remove the valve plate. Replace if necessary.

Reinstall all parts.

Quadra-Fire • QFP38 Series • 4061-300 Rev i • 9/09

25

Image 25
Contents Models Installation and OperationHomeowner Reference Information CongratulationsModel Number Serial Number Table of Contents = Contains updated information Appliance SetupLimited Lifetime Warranty Limited Lifetime Warranty Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Operating Instructions Gas Fireplace SafetyYour Fireplace Remote Controls Fixed Glass AssemblyClear Space Decorative Doors and FrontsFan Control Module System DescriptionAUX Outlet Plug Accent Lighting Initializing the System for the First Time ReceiverPRG Key PIN terminal Positions Slider Transmitter Remote Control with LCD Display Operating Procedure with Split Flow dual burner control Turn on the Appliance Temperature Indication DisplayTurn off the Appliance 11 Remote Flame Control Remote Flame ControlSmart Thermostat Transmitter Operation Room Thermostat Transmitter OptionRemote Actuated 120V Auxiliary Outlet accent lighting Fan Speed ControlManual Bypass of the Remote System Low Battery Power DetectionRemote Operation Key LockLighting Instructions IPI For Your Safety Read Before LightingInitial Break-in Procedure Frequently Asked QuestionsAfter Fireplace is Lit This cures the materials used to manufacture the fire- placeMaintenance Tasks-Homeowner Maintenance and ServiceMaintenance Tasks-Qualified Service Technician Bend Down Tab Fan Replacement & MaintenanceRemove Wing nuts Both sides Typical Appliance System Getting StartedTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Select Appliance Location Framing and ClearancesClearances Construct the Appliance ChaseMantels Mantel and Wall ProjectionsMantel Legs or Wall Projections Vent Termination Minimum Clearances Termination LocationsGas, Wood or Fuel Oil Termination Cap Minimum Clearances for Termination Approved Pipe Vent Information and DiagramsVent Table Key Use of ElbowsTop Vent Horizontal Termination Vent DiagramsOne Elbow Two Elbows Two 45 Elbows replacing One 90 ElbowNo Elbow Top Vent Vertical TerminationPipe Clearances to Combustibles Vent Clearances and FramingWall Penetration Framing Non-Combustible Wall PenetrationCeiling firestop Must be used between floors and attics Install the Ceiling FirestopFlat Ceiling Installation Install Attic Insulation ShieldVaulted Ceiling Installation Appliance Preparation Intake Adapter AssemblySecure and Level the Appliance Attach Pipe to the Firebox Assembly Install Vent PipeAssemble Vent Sections Assemble Pipe SectionsSlip Section Pilot Holes Assemble Slip SectionsDisassemble Vent Sections Secure the Vent SectionsCaulk Install Metal Roof Flashing13 Assembling the Storm Collar Assemble and Install Storm CollarHeat Shield Requirements for Horizontal Termination Install Vertical Termination CapFailure to maintain overlap may cause overheating and fire Install Horizontal Termination CapHHT Shrouds ShroudsField Constructed Shrouds Open Top Shroud may be used with DVP-TV, DVP-TVHW, SLP-TVHWMailbox Style Shroud Dimensions Min. Base Dims Gas Pressure Gas InformationGas Connection Technical Data Wiring RequirementsIntellifire Ignition System Wiring Electrical InformationIPI Module 4 from Sleeve Install the Heat Zone Kit before enclosing the appliance Junction Box InstallationHeat-Zone-Gas Facing Material Finishing43 3/8 Doors Outside Surface Fit Facing Template RemovalDoors Recessed Fit Minimum Vertical and Maximum Horizontal Dimensions Remove Fixed Glass Assembly Appliance SetupClean the Appliance Install the RefractoryLog Bracket is Pre-set for NG or LP Install Logs, Ember BedOverall placement of the first eight logs is shown in Figure Complete Log Installation Install Andirons, Lava Rock, RockwoolScrews Accent Lighting Set UpAdjust the Vertical Baffle Adjust the Air ShutterRemoving Fixed Glass Assembly Install Door FrontsReplacing Fixed Glass Assembly Troubleshooting TroubleshootingThis Opening Reference Materials Appliance Dimension DiagramDVP Vent Components Vent Components DiagramsDVP-TRAPFL DVP-HPC DVP-TRAP QFP38-NG, QFP38-LP Service PartsStocked Log Set Assembly Log 1 Back Log 4061-170 Ember BedAt Depot Light Assembly Valve Assembly Valve Assembly NG Optional Components Quadra-Fire, a brand of Hearth & Home Technologies Inc Contact Information7571 215th Street West, Lakeville, MN

QFP38-NG, QFP38-LP specifications

The Quadra-Fire QFP38-NG and QFP38-LP are high-performance gas fireplaces designed to deliver both warmth and aesthetic appeal to homes. These models are known for their advanced features, reliable technologies, and user-friendly characteristics, making them ideal choices for homeowners looking to enhance their living spaces.

One of the key features of the QFP38 series is its efficient heating capability. With impressive BTU output, both the QFP38-NG (natural gas) and QFP38-LP (liquid propane) models provide ample warmth, making them suitable for various room sizes. They utilize a powerful burner system that maximizes combustion efficiency, thereby delivering consistent heat while minimizing fuel consumption.

The QFP38 series is designed with a contemporary and elegant appearance, featuring a large viewing area that showcases the mesmerizing flame. The clean, modern lines and glass front make it an eye-catching centerpiece in any room. Additionally, these fireplaces come with customizable options, allowing homeowners to choose from different interior styles, including log sets and decorative fire glass, to match their decor preferences.

Another standout technology in these models is the advanced control system. The QFP38 series is compatible with remote control operation, enabling users to adjust the flames and heat settings from the comfort of their seating area. This feature enhances convenience, allowing homeowners to set the desired ambiance and warmth with ease.

Safety is a paramount concern, and the QFP38 fireplaces are equipped with several safety features. These include a built-in oxygen depletion sensor that automatically shuts off the gas supply in case of insufficient oxygen levels. Additionally, the sealed combustion design prevents indoor air contamination, providing peace of mind to users.

The installation process of the QFP38-NG and QFP38-LP is straightforward, thanks to their venting options that accommodate various home layouts. Both models are designed to be versatile, with horizontal and vertical venting capabilities, offering greater flexibility for installation.

In terms of maintenance, the QFP38 series is user-friendly, requiring minimal upkeep to ensure optimal performance. Regular cleaning and inspection of the glass and burner components are typically all that is needed to maintain the fireplace's efficiency and aesthetic appeal.

Overall, the Quadra-Fire QFP38-NG and QFP38-LP gas fireplaces combine cutting-edge technology, modern design, and safety features, making them excellent options for anyone looking to add warmth and style to their home. Whether used as a primary heat source or as an elegant focal point, these models are sure to enhance any living space.