Quadra-Fire QFP38-LP, QFP38-NG owner manual Vent Components Diagrams, DVP Vent Components

Page 67

B. Vent Components Diagrams

 

 

 

 

 

Effective Height/Length

 

 

 

 

 

 

 

 

 

Pipe

inches

mm

 

 

 

 

 

DVP4

4

102

 

 

 

 

 

DVP6

6

152

 

 

 

 

 

Effective

 

 

DVP12

12

305

Height/Length

 

 

DVP24

24

610

 

 

 

 

 

DVP36

36

914

 

 

 

 

 

DVP48

48

1219

 

 

 

 

 

DVP6A

3 - 6

76 - 152

 

 

 

 

 

DVP12A

3 - 12

76 - 305

 

 

 

 

DVP Pipe

(see chart)

10 in.

1 in.

(254 mm)

(25 mm)

Assembled

Height: 24 in./610 mm

Diameter: 10 in./254 mm

DVP-AS2

DVP-FS

Ceiling Firestop

10 in.

1-1/2 in.

(254 mm)

(38 mm)

UP

12 in.

(305 mm)

5in.

(127 mm)

DVP-HVS

Vent Support

4-7/8 in.

(124 mm)

10-1/2 in.

45°

(267 mm)

10-7/8 in.

(276 mm)

DVP45

45° Elbow

 

11-3/8 in.

 

(289 mm)

 

7-3/8 in.

 

 

(187 mm)

 

9-1/4 in.

 

1-1/4 in.

(235 mm)

1/2 in.

(32 mm)

13-1/4 in.

(13 mm) TYP

(337 mm)

 

DVP90ST

 

90° Elbow

 

 

 

 

 

 

 

 

 

 

12 in.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(305 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6 in.

 

 

 

 

 

 

 

 

 

 

 

 

1 in.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(152 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(25 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8 in.

(203 mm)

14 in.

(356 mm)

DVP-WS

Wall Shield Firestop

Figure 17.2 DVP Vent Components

Quadra-Fire • QFP38 Series • 4061-300 Rev i • 9/09

67

Image 67
Contents Models Installation and OperationHomeowner Reference Information CongratulationsModel Number Serial Number Table of Contents = Contains updated information Appliance SetupLimited Lifetime Warranty Limited Lifetime Warranty Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Operating Instructions Gas Fireplace SafetyYour Fireplace Decorative Doors and Fronts Fixed Glass AssemblyRemote Controls Clear SpaceFan Control Module System DescriptionAUX Outlet Plug Accent Lighting Initializing the System for the First Time ReceiverPRG Key PIN terminal Positions Slider Transmitter Remote Control with LCD Display Operating Procedure with Split Flow dual burner control Turn on the Appliance Temperature Indication DisplayTurn off the Appliance 11 Remote Flame Control Remote Flame ControlSmart Thermostat Transmitter Operation Room Thermostat Transmitter OptionRemote Actuated 120V Auxiliary Outlet accent lighting Fan Speed ControlKey Lock Low Battery Power DetectionManual Bypass of the Remote System Remote OperationLighting Instructions IPI For Your Safety Read Before LightingThis cures the materials used to manufacture the fire- place Frequently Asked QuestionsInitial Break-in Procedure After Fireplace is LitMaintenance Tasks-Homeowner Maintenance and ServiceMaintenance Tasks-Qualified Service Technician Bend Down Tab Fan Replacement & MaintenanceRemove Wing nuts Both sides Typical Appliance System Getting StartedTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Select Appliance Location Framing and ClearancesClearances Construct the Appliance ChaseMantels Mantel and Wall ProjectionsMantel Legs or Wall Projections Vent Termination Minimum Clearances Termination LocationsGas, Wood or Fuel Oil Termination Cap Minimum Clearances for Termination Use of Elbows Vent Information and DiagramsApproved Pipe Vent Table KeyTop Vent Horizontal Termination Vent DiagramsOne Elbow Two Elbows Two 45 Elbows replacing One 90 ElbowNo Elbow Top Vent Vertical TerminationNon-Combustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration FramingCeiling firestop Must be used between floors and attics Install the Ceiling FirestopFlat Ceiling Installation Install Attic Insulation ShieldVaulted Ceiling Installation Appliance Preparation Intake Adapter AssemblySecure and Level the Appliance Assemble Pipe Sections Install Vent PipeAttach Pipe to the Firebox Assembly Assemble Vent SectionsSlip Section Pilot Holes Assemble Slip SectionsDisassemble Vent Sections Secure the Vent SectionsCaulk Install Metal Roof Flashing13 Assembling the Storm Collar Assemble and Install Storm CollarHeat Shield Requirements for Horizontal Termination Install Vertical Termination CapFailure to maintain overlap may cause overheating and fire Install Horizontal Termination CapOpen Top Shroud may be used with DVP-TV, DVP-TVHW, SLP-TVHW ShroudsHHT Shrouds Field Constructed ShroudsMailbox Style Shroud Dimensions Min. Base Dims Gas Pressure Gas InformationGas Connection Electrical Information Wiring RequirementsTechnical Data Intellifire Ignition System WiringIPI Module 4 from Sleeve Install the Heat Zone Kit before enclosing the appliance Junction Box InstallationHeat-Zone-Gas Facing Material Finishing43 3/8 Doors Outside Surface Fit Facing Template RemovalDoors Recessed Fit Minimum Vertical and Maximum Horizontal Dimensions Install the Refractory Appliance SetupRemove Fixed Glass Assembly Clean the ApplianceLog Bracket is Pre-set for NG or LP Install Logs, Ember BedOverall placement of the first eight logs is shown in Figure Complete Log Installation Install Andirons, Lava Rock, RockwoolScrews Accent Lighting Set UpAdjust the Vertical Baffle Adjust the Air ShutterRemoving Fixed Glass Assembly Install Door FrontsReplacing Fixed Glass Assembly Troubleshooting TroubleshootingThis Opening Reference Materials Appliance Dimension DiagramDVP Vent Components Vent Components DiagramsDVP-TRAPFL DVP-HPC DVP-TRAP QFP38-NG, QFP38-LP Service PartsStocked Log Set Assembly Log 1 Back Log 4061-170 Ember BedAt Depot Light Assembly Valve Assembly Valve Assembly NG Optional Components Quadra-Fire, a brand of Hearth & Home Technologies Inc Contact Information7571 215th Street West, Lakeville, MN

QFP38-NG, QFP38-LP specifications

The Quadra-Fire QFP38-NG and QFP38-LP are high-performance gas fireplaces designed to deliver both warmth and aesthetic appeal to homes. These models are known for their advanced features, reliable technologies, and user-friendly characteristics, making them ideal choices for homeowners looking to enhance their living spaces.

One of the key features of the QFP38 series is its efficient heating capability. With impressive BTU output, both the QFP38-NG (natural gas) and QFP38-LP (liquid propane) models provide ample warmth, making them suitable for various room sizes. They utilize a powerful burner system that maximizes combustion efficiency, thereby delivering consistent heat while minimizing fuel consumption.

The QFP38 series is designed with a contemporary and elegant appearance, featuring a large viewing area that showcases the mesmerizing flame. The clean, modern lines and glass front make it an eye-catching centerpiece in any room. Additionally, these fireplaces come with customizable options, allowing homeowners to choose from different interior styles, including log sets and decorative fire glass, to match their decor preferences.

Another standout technology in these models is the advanced control system. The QFP38 series is compatible with remote control operation, enabling users to adjust the flames and heat settings from the comfort of their seating area. This feature enhances convenience, allowing homeowners to set the desired ambiance and warmth with ease.

Safety is a paramount concern, and the QFP38 fireplaces are equipped with several safety features. These include a built-in oxygen depletion sensor that automatically shuts off the gas supply in case of insufficient oxygen levels. Additionally, the sealed combustion design prevents indoor air contamination, providing peace of mind to users.

The installation process of the QFP38-NG and QFP38-LP is straightforward, thanks to their venting options that accommodate various home layouts. Both models are designed to be versatile, with horizontal and vertical venting capabilities, offering greater flexibility for installation.

In terms of maintenance, the QFP38 series is user-friendly, requiring minimal upkeep to ensure optimal performance. Regular cleaning and inspection of the glass and burner components are typically all that is needed to maintain the fireplace's efficiency and aesthetic appeal.

Overall, the Quadra-Fire QFP38-NG and QFP38-LP gas fireplaces combine cutting-edge technology, modern design, and safety features, making them excellent options for anyone looking to add warmth and style to their home. Whether used as a primary heat source or as an elegant focal point, these models are sure to enhance any living space.