Clearances to Electrical Service

Dimension Descriptions

AClearance above the ground, a veranda, porch, deck or balcony - 12 in. (30 cm) minimum. *

BClearance to window or door that may be opened – 10,000 BTUs or less, 6 in. (15 cm) minimum; 10,000-50,000 BTUs, 9 in. (23 cm) minimum; over 50,000 BTUs, 12 in. (30 cm) minimum. *

CClearance to permanently closed window – 12 in. (30 cm) minimum - recommended to prevent condensation on window.

DVertical clearance to ventilated soffit located above the termination within a horizontal distance of 2 ft (60 cm) from the centerline of the termination

– 18 in. (46 cm) minimum. **

EVertical clearance to unventilated soffit - 12 in. (30 cm) minimum. **

FClearance to outside corner - 6 in. (15 cm) minimum.

GClearance to inside corner - 6 in. (15 cm) minimum.

HNot to be installed above a meter/regulator assembly within 3 ft (90 cm) horizontally* from the center line of the regulator (Canada only)

IClearance to service regulator vent outlet – 3 ft (.91 m) U.S. minimum and 3 ft (.91 m) Canada minimum. *

JClearance to non-mechanical air supply inlet into building or the combustion air inlet to any other appliance – 9” (23 cm) U.S. minimum and 12 in. (30 cm) Canada minimum. *

KClearance to mechanical air supply inlet - 3 ft (.91 m) U.S. minimum and 6 ft (1.8 m) Canada minimum. *

LClearance above a paved sidewalk or paved driveway located on public property - 7 ft (2.1 m) minimum.

A vent may not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings.

MClearance under veranda, porch, deck or balcony - 12 in. (30 cm) minimum. * Recommended 30 in. (76 cm) for vinyl or plastic.

Only permitted if veranda, porch, deck or balcony is fully open on a minimum of 2 sides beneath the floor. *

NVertical clearance between two horizontal termination caps – 12 in. (30 cm) minimum.

OHorizontal clearance between two horizontal termination caps – 12 in. (30 cm) minimum.

Figure 6.3 Minimum Clearances for Termination

P6” - Non-vinyl sidewalls 12” – Vinyl sidewalls

Q18” – Non-vinyl soffit and overhang 42” – Vinyl soffit and overhang

R8 ft.

 

 

S min

T max

1 cap

 

3 ft

2 x S actual

2 caps

 

6 ft

1 x S actual

3 caps

 

9 ft

2/3 x S actual

4 caps

 

12 ft

1/2 x S actual

S min = # term caps x 3

T max = (2/# term caps) x S (actual)

U6” min. – Clearance from sides of electrical service. W 12” min. – Clearance above electrical service.

* As specified in CGA B149 Installation Codes

Note: Local codes or regulations may require different clearances. ** Clearance required to vinyl soffit material – 30 in. (76 cm) minimum.

Note: Location of the vent termination must not interfere with access to the electrical service.

WARNING!

In the U.S.: Vent system termination is NOT permitted in screened porches. You must follow side wall, overhang and ground clearances as stated in the instructions.

In Canada: Vent system termination is NOT permitted in screened porches. Vent system termination is permitted in porch areas with two or more sides open. You must follow all side wall, overhang and ground clearances as stated in the instructions.

Hearth & Home Technologies assumes no responsibility for the improper performance of the appliance when the venting system does not meet these requirements.

CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED.

32

Quadra-Fire • QFP38 Series • 4061-300 Rev i • 9/09

Image 32
Contents Installation and Operation ModelsModel Number Serial Number CongratulationsHomeowner Reference Information Table of Contents Appliance Setup = Contains updated informationLimited Lifetime Warranty Limited Lifetime Warranty Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Your Fireplace Gas Fireplace SafetyOperating Instructions Fixed Glass Assembly Remote ControlsClear Space Decorative Doors and FrontsAUX Outlet Plug Accent Lighting System DescriptionFan Control Module PRG Key PIN terminal Positions Slider ReceiverInitializing the System for the First Time Transmitter Remote Control with LCD Display Operating Procedure with Split Flow dual burner control Turn off the Appliance Temperature Indication DisplayTurn on the Appliance Remote Flame Control 11 Remote Flame ControlRoom Thermostat Transmitter Option Smart Thermostat Transmitter OperationFan Speed Control Remote Actuated 120V Auxiliary Outlet accent lightingLow Battery Power Detection Manual Bypass of the Remote SystemRemote Operation Key LockFor Your Safety Read Before Lighting Lighting Instructions IPIFrequently Asked Questions Initial Break-in ProcedureAfter Fireplace is Lit This cures the materials used to manufacture the fire- placeMaintenance and Service Maintenance Tasks-HomeownerMaintenance Tasks-Qualified Service Technician Fan Replacement & Maintenance Bend Down TabRemove Wing nuts Both sides Getting Started Typical Appliance SystemInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Framing and Clearances Select Appliance LocationConstruct the Appliance Chase ClearancesMantel Legs or Wall Projections Mantel and Wall ProjectionsMantels Gas, Wood or Fuel Oil Termination Cap Termination LocationsVent Termination Minimum Clearances Minimum Clearances for Termination Vent Information and Diagrams Approved PipeVent Table Key Use of ElbowsOne Elbow Vent DiagramsTop Vent Horizontal Termination Two 45 Elbows replacing One 90 Elbow Two ElbowsTop Vent Vertical Termination No ElbowVent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Non-Combustible Wall PenetrationInstall the Ceiling Firestop Ceiling firestop Must be used between floors and atticsVaulted Ceiling Installation Install Attic Insulation ShieldFlat Ceiling Installation Secure and Level the Appliance Intake Adapter AssemblyAppliance Preparation Install Vent Pipe Attach Pipe to the Firebox AssemblyAssemble Vent Sections Assemble Pipe SectionsAssemble Slip Sections Slip Section Pilot HolesSecure the Vent Sections Disassemble Vent SectionsInstall Metal Roof Flashing CaulkAssemble and Install Storm Collar 13 Assembling the Storm CollarInstall Vertical Termination Cap Heat Shield Requirements for Horizontal TerminationInstall Horizontal Termination Cap Failure to maintain overlap may cause overheating and fireShrouds HHT ShroudsField Constructed Shrouds Open Top Shroud may be used with DVP-TV, DVP-TVHW, SLP-TVHWMailbox Style Shroud Dimensions Min. Base Dims Gas Connection Gas InformationGas Pressure Wiring Requirements Technical DataIntellifire Ignition System Wiring Electrical InformationIPI Module 4 from Sleeve Heat-Zone-Gas Junction Box InstallationInstall the Heat Zone Kit before enclosing the appliance 43 3/8 FinishingFacing Material Doors Recessed Fit Facing Template RemovalDoors Outside Surface Fit Minimum Vertical and Maximum Horizontal Dimensions Appliance Setup Remove Fixed Glass AssemblyClean the Appliance Install the RefractoryInstall Logs, Ember Bed Log Bracket is Pre-set for NG or LPOverall placement of the first eight logs is shown in Figure Install Andirons, Lava Rock, Rockwool Complete Log InstallationAccent Lighting Set Up ScrewsAdjust the Air Shutter Adjust the Vertical BaffleReplacing Fixed Glass Assembly Install Door FrontsRemoving Fixed Glass Assembly Troubleshooting TroubleshootingThis Opening Appliance Dimension Diagram Reference MaterialsVent Components Diagrams DVP Vent ComponentsDVP-TRAPFL DVP-HPC DVP-TRAP Service Parts QFP38-NG, QFP38-LPAt Depot Log Set Assembly Log 1 Back Log 4061-170 Ember BedStocked Light Assembly Valve Assembly Valve Assembly NG Optional Components 7571 215th Street West, Lakeville, MN Contact InformationQuadra-Fire, a brand of Hearth & Home Technologies Inc

QFP38-NG, QFP38-LP specifications

The Quadra-Fire QFP38-NG and QFP38-LP are high-performance gas fireplaces designed to deliver both warmth and aesthetic appeal to homes. These models are known for their advanced features, reliable technologies, and user-friendly characteristics, making them ideal choices for homeowners looking to enhance their living spaces.

One of the key features of the QFP38 series is its efficient heating capability. With impressive BTU output, both the QFP38-NG (natural gas) and QFP38-LP (liquid propane) models provide ample warmth, making them suitable for various room sizes. They utilize a powerful burner system that maximizes combustion efficiency, thereby delivering consistent heat while minimizing fuel consumption.

The QFP38 series is designed with a contemporary and elegant appearance, featuring a large viewing area that showcases the mesmerizing flame. The clean, modern lines and glass front make it an eye-catching centerpiece in any room. Additionally, these fireplaces come with customizable options, allowing homeowners to choose from different interior styles, including log sets and decorative fire glass, to match their decor preferences.

Another standout technology in these models is the advanced control system. The QFP38 series is compatible with remote control operation, enabling users to adjust the flames and heat settings from the comfort of their seating area. This feature enhances convenience, allowing homeowners to set the desired ambiance and warmth with ease.

Safety is a paramount concern, and the QFP38 fireplaces are equipped with several safety features. These include a built-in oxygen depletion sensor that automatically shuts off the gas supply in case of insufficient oxygen levels. Additionally, the sealed combustion design prevents indoor air contamination, providing peace of mind to users.

The installation process of the QFP38-NG and QFP38-LP is straightforward, thanks to their venting options that accommodate various home layouts. Both models are designed to be versatile, with horizontal and vertical venting capabilities, offering greater flexibility for installation.

In terms of maintenance, the QFP38 series is user-friendly, requiring minimal upkeep to ensure optimal performance. Regular cleaning and inspection of the glass and burner components are typically all that is needed to maintain the fireplace's efficiency and aesthetic appeal.

Overall, the Quadra-Fire QFP38-NG and QFP38-LP gas fireplaces combine cutting-edge technology, modern design, and safety features, making them excellent options for anyone looking to add warmth and style to their home. Whether used as a primary heat source or as an elegant focal point, these models are sure to enhance any living space.