Quadra-Fire QFP38-NG, QFP38-LP owner manual Install Vertical Termination Cap

Page 46

G. Install Vertical Termination Cap

Attach the vertical termination cap by sliding the inner collar of the cap into the inner flue of the pipe section while placing the outer collar of the cap over the outer flue of the pipe section.

Secure the cap by driving three self-tapping screws (supplied) through the pilot holes in the outer collar of the cap into the outer flue of the pipe (see Figure 10.15).

Termination Cap

Brackets/

 

(1 of three)

 

 

 

Bolts

 

 

Storm

Collar

Screws

Caulk

Figure 10.15

H. Heat Shield Requirements for Horizontal Termination

WARNING! Risk of Fire! To prevent overheating and fire, heat shields must extend through the entire wall thick- ness.

DO NOT remove the heat shields attached to the wall shield firestop and the horizontal termination cap.

Heat shields must overlap 1-1/2 in. (38 mm) mini- mum.

There are two sections of the heat shield. One section is factory-attached to the wall shield firestop. The other section is factory-attached to the cap. See Figure 10.16.

If the wall thickness does not allow the required 1-1/2 in. (38 mm) heat shield overlap when installed, an extended heat shield must be used.

If the wall thickness is less than 4 in./102 mm, the heat shields on the cap and wall shield firestop must to be trimmed. A minimum 1-1/2 in. (38 mm) overlap MUST be maintained.

Use an extended heat shield if the finished wall thickness is greater than 7-1/4 in. (184 mm).

The extended heat shield may need to be cut to length maintaining sufficient length for a 1-1/2 in. (38 mm) overlap between heat shields.

Attach the extended heat shield to either of the existing heat shields using the screws supplied with the extended heat shield. Refer to “Vent Components Diagrams” in the back of this manual.

Rest the small leg on the extended heat shield on top of the pipe section to properly space it from the pipe section.

Important Notice: Heat shields may not be field constructed.

46

Quadra-Fire • QFP38 Series • 4061-300 Rev i • 9/09

Image 46
Contents Installation and Operation ModelsHomeowner Reference Information CongratulationsModel Number Serial Number Table of Contents Appliance Setup = Contains updated informationLimited Lifetime Warranty Limited Lifetime Warranty Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Operating Instructions Gas Fireplace SafetyYour Fireplace Clear Space Fixed Glass AssemblyRemote Controls Decorative Doors and FrontsFan Control Module System DescriptionAUX Outlet Plug Accent Lighting Initializing the System for the First Time ReceiverPRG Key PIN terminal Positions Slider Transmitter Remote Control with LCD Display Operating Procedure with Split Flow dual burner control Turn on the Appliance Temperature Indication DisplayTurn off the Appliance Remote Flame Control 11 Remote Flame ControlRoom Thermostat Transmitter Option Smart Thermostat Transmitter OperationFan Speed Control Remote Actuated 120V Auxiliary Outlet accent lightingRemote Operation Low Battery Power DetectionManual Bypass of the Remote System Key LockFor Your Safety Read Before Lighting Lighting Instructions IPIAfter Fireplace is Lit Frequently Asked QuestionsInitial Break-in Procedure This cures the materials used to manufacture the fire- placeMaintenance and Service Maintenance Tasks-HomeownerMaintenance Tasks-Qualified Service Technician Fan Replacement & Maintenance Bend Down TabRemove Wing nuts Both sides Getting Started Typical Appliance SystemTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Framing and Clearances Select Appliance LocationConstruct the Appliance Chase ClearancesMantels Mantel and Wall ProjectionsMantel Legs or Wall Projections Vent Termination Minimum Clearances Termination LocationsGas, Wood or Fuel Oil Termination Cap Minimum Clearances for Termination Vent Table Key Vent Information and DiagramsApproved Pipe Use of ElbowsTop Vent Horizontal Termination Vent DiagramsOne Elbow Two 45 Elbows replacing One 90 Elbow Two ElbowsTop Vent Vertical Termination No ElbowWall Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Non-Combustible Wall PenetrationInstall the Ceiling Firestop Ceiling firestop Must be used between floors and atticsFlat Ceiling Installation Install Attic Insulation ShieldVaulted Ceiling Installation Appliance Preparation Intake Adapter AssemblySecure and Level the Appliance Assemble Vent Sections Install Vent PipeAttach Pipe to the Firebox Assembly Assemble Pipe SectionsAssemble Slip Sections Slip Section Pilot HolesSecure the Vent Sections Disassemble Vent SectionsInstall Metal Roof Flashing CaulkAssemble and Install Storm Collar 13 Assembling the Storm CollarInstall Vertical Termination Cap Heat Shield Requirements for Horizontal TerminationInstall Horizontal Termination Cap Failure to maintain overlap may cause overheating and fireField Constructed Shrouds ShroudsHHT Shrouds Open Top Shroud may be used with DVP-TV, DVP-TVHW, SLP-TVHWMailbox Style Shroud Dimensions Min. Base Dims Gas Pressure Gas InformationGas Connection Intellifire Ignition System Wiring Wiring RequirementsTechnical Data Electrical InformationIPI Module 4 from Sleeve Install the Heat Zone Kit before enclosing the appliance Junction Box InstallationHeat-Zone-Gas Facing Material Finishing43 3/8 Doors Outside Surface Fit Facing Template RemovalDoors Recessed Fit Minimum Vertical and Maximum Horizontal Dimensions Clean the Appliance Appliance SetupRemove Fixed Glass Assembly Install the RefractoryInstall Logs, Ember Bed Log Bracket is Pre-set for NG or LPOverall placement of the first eight logs is shown in Figure Install Andirons, Lava Rock, Rockwool Complete Log InstallationAccent Lighting Set Up ScrewsAdjust the Air Shutter Adjust the Vertical BaffleRemoving Fixed Glass Assembly Install Door FrontsReplacing Fixed Glass Assembly Troubleshooting TroubleshootingThis Opening Appliance Dimension Diagram Reference MaterialsVent Components Diagrams DVP Vent ComponentsDVP-TRAPFL DVP-HPC DVP-TRAP Service Parts QFP38-NG, QFP38-LPStocked Log Set Assembly Log 1 Back Log 4061-170 Ember BedAt Depot Light Assembly Valve Assembly Valve Assembly NG Optional Components Quadra-Fire, a brand of Hearth & Home Technologies Inc Contact Information7571 215th Street West, Lakeville, MN

QFP38-NG, QFP38-LP specifications

The Quadra-Fire QFP38-NG and QFP38-LP are high-performance gas fireplaces designed to deliver both warmth and aesthetic appeal to homes. These models are known for their advanced features, reliable technologies, and user-friendly characteristics, making them ideal choices for homeowners looking to enhance their living spaces.

One of the key features of the QFP38 series is its efficient heating capability. With impressive BTU output, both the QFP38-NG (natural gas) and QFP38-LP (liquid propane) models provide ample warmth, making them suitable for various room sizes. They utilize a powerful burner system that maximizes combustion efficiency, thereby delivering consistent heat while minimizing fuel consumption.

The QFP38 series is designed with a contemporary and elegant appearance, featuring a large viewing area that showcases the mesmerizing flame. The clean, modern lines and glass front make it an eye-catching centerpiece in any room. Additionally, these fireplaces come with customizable options, allowing homeowners to choose from different interior styles, including log sets and decorative fire glass, to match their decor preferences.

Another standout technology in these models is the advanced control system. The QFP38 series is compatible with remote control operation, enabling users to adjust the flames and heat settings from the comfort of their seating area. This feature enhances convenience, allowing homeowners to set the desired ambiance and warmth with ease.

Safety is a paramount concern, and the QFP38 fireplaces are equipped with several safety features. These include a built-in oxygen depletion sensor that automatically shuts off the gas supply in case of insufficient oxygen levels. Additionally, the sealed combustion design prevents indoor air contamination, providing peace of mind to users.

The installation process of the QFP38-NG and QFP38-LP is straightforward, thanks to their venting options that accommodate various home layouts. Both models are designed to be versatile, with horizontal and vertical venting capabilities, offering greater flexibility for installation.

In terms of maintenance, the QFP38 series is user-friendly, requiring minimal upkeep to ensure optimal performance. Regular cleaning and inspection of the glass and burner components are typically all that is needed to maintain the fireplace's efficiency and aesthetic appeal.

Overall, the Quadra-Fire QFP38-NG and QFP38-LP gas fireplaces combine cutting-edge technology, modern design, and safety features, making them excellent options for anyone looking to add warmth and style to their home. Whether used as a primary heat source or as an elegant focal point, these models are sure to enhance any living space.