Quadra-Fire QVI-30FB owner manual Positioning, Leveling, Securing the Insert, Gas Control System

Page 16

Step 2. Positioning, Leveling, and

Securing the Insert

Remote Control

The receiver for the remotes must be installed BETWEEN the base pan of the insert and the firebox of the wood-burn- ing fireplace (see photo below).

EXISTING SIDE

REFRACTORY

REMOTE

RECEIVER

UNIT

EXISTING BOTTOM

OFFIREPLACE

Place the insert into position.

Level the insert from side to side and from front to back. Use the leveling legs if necessary to set each corner of the base. The levelling legs are mounted behind the fan cover plate. For location of fan cover plate, see Figure 11 on page 17.

Step 3. The Gas Control System

!WARNING: THIS UNIT IS NOT FOR USE WITH SOLID FUEL.

These models use a standing pilot ignition type of gas con- trol system.

Standing Pilot Ignition System

This system includes millivolt control valve, standing pilot, thermopile/thermocouple flame sensor, and piezo ignitor.

WARNING: 110-120 VAC MUST NEVER BE

!CONNECTED TO A CONTROL VALVE IN A MILLIVOLT SYSTEM.

STANDING PILOT

Figure 6. Gas Controls System

Step 4. The Gas Supply Line

NOTE: Have the gas supply line installed in accordance with local building codes by a qualified installer approved and/or licensed as required by the locality. (In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter).

NOTE: Before the first firing of the fireplace, the gas supply line should be purged of any trapped air.

NOTE: Consult local building codes to properly size the gas supply line leading to the 1/2 inch (13 mm) hook-up at the unit.

This gas fireplace is designed to accept a 1/2 inch

(13 mm) gas supply line. To install the gas supply line:

A listed (and Commonweatlh of Massachusetts approved) 1/2 inch (13mm) tee-handle manual shut-off valve and a listed flexible gas connector are connected to the 1/2 inch (13mm) inlet of the control valve. NOTE: If substi- tuting for these components, please consult local codes for compliance.

Locate the gas line access hole in the outer casing of the fireplace.

Insert the gas supply line through the gas line hole and connect it to the shut-off valve.

When attaching the pipe, support the control so that the lines are not bent or torn.

After the gas line installation is complete, all connec- tions must be tightened and checked for leaks with a commercially-available, non-corrosive leak check solu- tion. Be sure to rinse off all leak check solution following testing.

!WARNING: DO NOT USE AN OPEN FLAME TO CHECK FOR GAS LEAKS.

GAS

FLEXIBLE

CONTROLS

SHUT-OFF

GAS LINE

 

Figure 7. Gas Supply Line

16

Quadra-FireQVI-30FB2020-900 Rev. H • 9/07

Image 16
Contents QVI-30FB What to do if you smell gasSafety and Warning Information Table of Contents Service Parts Log Set AssemblyService Parts List Standing Pilot Valve Assembly High Altitude Installations Installation CodesAppliance Certification CertificationVent Directly BELOW. Keep Clear of ALL OB- Structions Requirements for the Commonwealth of MassachusettsManufacturer Requirements Pre-install Preparation Introducing the Quadra-Fire Gas AppliancesDiagram of insert and minimum fireplace dimensions Diagram and model dimensions Installing the Vent System Rectly to the Exhaust Collar of the UnitHorizontal Overhang Minimum Height from Roof to Lowest Discharge OpeningFactory installed to Stainless steel section Typical configuration of vent liners Positioning, Leveling, Securing the Insert Gas Control SystemGas Supply Line Connected to a Control Valve in a Millivolt SystemWiring the Fireplace Standing Pilot Ignition Wiring DiagramGas Pressure Requirements Pressure Natural Gas PropaneJunction box installation To service or cleanServing the blower Installing Logs and Ember Material Installing Trim SurroundsShutter Settings Positioning the LogsBefore Lighting the Appliance Double-check for faulty componentsDouble-check vent terminations for obstructions After the Installation Lighting the ApplianceStanding Pilot Ignition What to do if YOU Smell GASAppliance Maintenance Cleaning Glass DoorImportant Turn OFF the GAS Before Servicing Your Fireplace Replacing old ember materialTroubleshooting Be Placed in this Opening Lifetime Warranty