4Maintaining and Servicing Your Appliance

Appliance Maintenance

Although the frequency of servicing and maintenance will depend on use and the type of installation, you should have a qualified service technician perform an appliance check- up at the beginning of each heating season. See the table below for specific guidelines regarding each fireplace main- tenance task.

IMPORTANT: TURN OFF THE GAS BEFORE SERVICING YOUR FIREPLACE.

Replacing old ember material

Frequency: Once annually, during the checkup.

By: Qualified service technician.

Task: Brush away loose ember material near the burner. Replace old ember material with new dime-size and shape pieces of Golden Ember (DE-93) and Glowing Ember (050- 721). New ember material should be placed alternately on top of the burner - a layer of Golden Ember, a layer of Glowing Ember, and so on. Save the remaining ember material and repeat this procedure at your next servicing. For more information, see Placing Ember Material.

Cleaning Burner and Controls Frequency: Once annually. By: Qualified service technician.

Task: Brush or vacuum the control compartment, fireplace logs and burner areas surrounding the logs.

Checking Flame Patterns, Flame Height

Frequency: Periodically.

By: Qualified service technician/Home owner.

Task: Make a visual check of your fireplace’s flame patterns. Make sure the flames are steady - not lifting or floating. See Figure 16. The thermopile/thermocouple (standing pilot) tips should be covered with flame. See Figure 6.

MAKE SURE THE FLAMES

ARE STEADY—NOT

LIFTING OR FLOATING.

Figure 16. Burner Flame Patterns

Checking Vent System

Frequency: Before initial use and at least annually thereafter, more frequently if possible.

By: Qualified service technician/Home owner.

Task: Inspect the external vent cap on a regular basis to ensure that no debris is interfering with the flow of air. Inspect entire vent system for proper function.

Cleaning Glass Door

Frequency: After the first 3 to 4 hours of use. As neces- sary after initial cleaning.

By: Home owner.

Task: Remove and clean glass after the first 3 to 4 hours of use. After the initial cleaning, clean as necessary, particu- larly after adding new ember (flame colorant) material. Film deposits on the inside of the glass door should be cleaned off using a household glass cleaner. NOTE: DO NOT handle or attempt to clean the door when it is hot and DO NOT use abrasive cleaners.

22

Quadra-FireQVI-30FB2020-900 Rev. H • 9/07

Image 22
Contents QVI-30FB What to do if you smell gasSafety and Warning Information Table of Contents Service Parts Log Set AssemblyService Parts List Standing Pilot Valve Assembly Appliance Certification High Altitude InstallationsInstallation Codes CertificationVent Directly BELOW. Keep Clear of ALL OB- Structions Requirements for the Commonwealth of MassachusettsManufacturer Requirements Pre-install Preparation Introducing the Quadra-Fire Gas AppliancesDiagram of insert and minimum fireplace dimensions Diagram and model dimensions Installing the Vent System Rectly to the Exhaust Collar of the UnitHorizontal Overhang Minimum Height from Roof to Lowest Discharge OpeningFactory installed to Stainless steel section Typical configuration of vent liners Gas Supply Line Positioning, Leveling, Securing the InsertGas Control System Connected to a Control Valve in a Millivolt SystemGas Pressure Requirements Wiring the FireplaceStanding Pilot Ignition Wiring Diagram Pressure Natural Gas PropaneJunction box installation To service or cleanServing the blower Shutter Settings Installing Logs and Ember MaterialInstalling Trim Surrounds Positioning the LogsBefore Lighting the Appliance Double-check for faulty componentsDouble-check vent terminations for obstructions Standing Pilot Ignition After the InstallationLighting the Appliance What to do if YOU Smell GASImportant Turn OFF the GAS Before Servicing Your Fireplace Appliance MaintenanceCleaning Glass Door Replacing old ember materialTroubleshooting Be Placed in this Opening Lifetime Warranty