Quadra-Fire 7100FP-NL-B warranty Mark the Exit Point of the Roof, Cut Out the Hole in the Roof

Page 27

R

7100FP EPA Woodburning Fireplace

NOTE: Wiring for blowers must be done before framed enclosure is completed. If using a Heat Zone kit, it also must be installed before enclosure is complete.

Mark the Exit Point of the Roof

Locate the point where the chimney will exit the roof by plumbing down to the center of the chimney. Drive a nail up through the roof to mark the center. See Figure 27.1.

• Cut Out the Hole in the Roof

Measure to either side of the nail and mark the 14-1/2 in. x 14-1/2 in. (368 mm x 368 mm) opening required. This is measured on the horizontal; actual length may be larg- er depending on the pitch of the roof. Cut out and frame the opening. See Chapter 25 of the Uniform Building Code for roof framing details.

WARNING

Fire Risk

Must maintain 2 in. (51 mm) air clearance to insulation and other combustible materials.

Assemble the Chimney Sections Through the Roof

Continue to add chimney sections through the roof open- ing, maintaining at least a 2 in. (51 mm) air space to com- bustible materials.

• Install the Roof Flashing

If a roof flashing is to be used, install the roof flashing appropriate to the roof pitch and install a termination cap and storm collar following the instructions shipped with the cap.

For chase installations you can use a round termination cap, a round telescoping termination cap or a square termination cap (See pages 61-62). A chase installation must use a chase top. Chase tops are available from your dealer. See page 14 for building a chase.

• Install the Chimney Air Kit (required in Canada):

When installing the chimney air kit, follow the instructions provided with this accessory. See page 23.

• Completion of the Enclosure

Complete the fireplace enclosure, allowing space for outside air ducts. Electrical wiring should not come in contact with the fireplace. A minimum clearance of 1/2 in. (13 mm) must be maintained between the fireplace back and 1 in. (25 mm) minimum clearances to sides and the enclosure.

Figure 27.1 Ceiling/Attic Construction

September 7, 2007

433-1390D

Page 27

Image 27
Contents Fire Risk 7100FP-BK-B 7100FP-GD-B 7100FP-NL-B7100FP EPA Woodburning Fireplace 007Location on hang tag on right side of fireplace Table of Contents Listing and Code Approvals Appliance CertificationMobile Home Approved BTU & Efficiency Specifications 7100FP EPA Woodburning Fireplace Glass SpecificationsAsphyxiation Risk Design and Installation ConsiderationsGetting Started Negative PressureSeptember 7 433-1390D Typical Fireplace System 7100FP EPA Woodburning Fireplace Typical Fireplace System7100FP EPA Woodburning Fireplace Tools and Supplies Needed Inspect Fireplace and ComponentsFire Risk Explosion Risk Framing and Clearances Selecting Fireplace LocationModel #7100FP Clearances to Combustible Materials 7100FP EPA Woodburning Fireplace ClearancesCombustible Materials Frame the FireplaceMinimum Clearances to Combustibles Non-Combustible MaterialsSuggestions Electrical Access and Wiring DiagramMaterials 7100FP EPA Woodburning Fireplace Construct the ChaseInstall the Outside Air Kit Installation of FireplaceFire Risk Asphyxiation Risk Risk of Smoke SpillageHandle Left Closed Handle Right Open Attic space Auxiliary Convection Air SystemConvection Air Lock Place the Protective Metal Hearth Strips 7100FP EPA Woodburning Fireplace Secure the FireplacePosition the Fireplace Level the FireplaceChimney Assembly Chimney Termination Requirements 7100FP EPA Woodburning Fireplace Chimney RequirementsExample 7100FP EPA Woodburning Fireplace Using Offsets/ReturnsAssembling Chimney Sections Assembling Chimney Sections for the SL- 300 SeriesInstalling Flex Pipe Install the Ceiling FirestopsSecure the Chimney Double-check the Chimney AssemblySlanted Roofs Complete the EnclosureChimney Termination 2-10-03 Rule Chimney Termination Requirements See Figures 26.1Cut Out the Hole in the Roof Install the Roof FlashingInstall the Chimney Air Kit required in Canada Mark the Exit Point of the RoofConsult local codes for framing details Install the Termination Cap 7100FP EPA Woodburning Fireplace Chase TopChase Top Framing For installations utilizing a Round Telescoping Termination Blower Cord Location AccessoriesBlower Replacement Blower Replacement InstructionsRight Door Door and Door GasketMinimum Clearance to Combustibles 7100FP EPA Woodburning Fireplace Heat Zone Kit20 ft 3 6m 10 ft 1 3m Run Length Cut Pipe 20 40 ft 6-12mBracket Remove 2 screws 7100FP EPA Woodburning Fireplace Timer Assembly Replacement7100FP EPA Woodburning Fireplace Timer PlateHearth Extension FinishingPositioning the Protective Metal Hearth Strips Model # 7100FPOuter Can Flange Fascia Tile or Marble Combustible Floor Cardboard or Metal Template Finishing MaterialNon-Combustible Material Non-Combustible Sealant MaterialRisk of Fire Complete installationMantel Specifications 7100FP EPA Woodburning Fireplace MantelOperating Instructions General InformationKeep open during use Glass Doors 7100FP EPA Woodburning Fireplace Outside AirClear Space Near the Fireplace FirescreenMinimum Clearance to Combustible 1 in mm from the B-Vent 7100FP EPA Woodburning Fireplace Blower OperationHeat Zone Operation Wood Fuel Hardwood vs. Softwood7100FP EPA Woodburning Fireplace Moisture content SeasoningStoring Wood 7100FP EPA Woodburning Fireplace Starting a Fire Slide Air Control Kindling or 1st stage2nd stage Final stageFor maximum operating efficiency with the lowest Emissions, follow these operating procedures7100FP EPA Woodburning Fireplace Burning Guidelines Opacity Burn RatesChimney Fire Overfiring Fire SafetyTroubleshooting Understanding Vent ProblemsDraft Problems Factory-built Fireplaces Troubleshooting If I can’t get a good fire going, what am I doing wrong? Diagnostic Question Possible Causes of Condition SolutionsDon’t get enough/any heat. What can I do about it? General Maintenance Maintenance and Servicing the FireplaceFire Risk Injury Risk Glass ReplacementGlass Cleaning Disposal of AshesBrick and take it to your authorized dealer 7100FP EPA Woodburning Fireplace Brick ReplacementUse Part 832-2370 when ordering individual brick. Pro Vide brick dimension or copy this page, mark the desiredInspect Maintenance Tasks Maintenance Task ListFireplace Dimensions Reference Materials7100FP FS340 16-3/4 425 mm 7100FP EPA Woodburning Fireplace Chimney ComponentsCatalog Description Catalog No FS338 14-1/2 368 mm FS339 18-3/8 467 mm15-3/4 Glass Size 12-3/50 w x 15 h 17 13 1514 27 25 2124 7100FP EPA Woodburning Fireplace Fireplace Diagram7100FP EPA Woodburning Fireplace Service Parts Part DescriptionAlphabetical Order RIVNUT-REPAIR Accessories7100FP EPA Woodburning Fireplace Warranty Policy Lifetime Warranty7100FP EPA Certified Woodburning Fireplace Contact InformationDealer Telephone

7100FP-BK-B, 7100FP-GD-B, 7100FP-NL-B specifications

The Quadra-Fire 7100FP series, including the models 7100FP-BK-B, 7100FP-NL-B, and 7100FP-GD-B, represents an exceptional choice for homeowners seeking efficient and powerful heating solutions. These fireplaces are designed to provide warmth and ambiance while incorporating advanced technologies that enhance performance and ease of use.

One of the primary features of the 7100FP series is its large viewing area, which allows homeowners to enjoy the mesmerizing flames while increasing the aesthetic appeal of any living space. The generous size of the firebox ensures that it can accommodate sizable logs, providing longer burn times and requiring less frequent reloading. This feature is particularly beneficial for those who appreciate an extended, leisurely evening by the fire.

A hallmark of the Quadra-Fire brand is its innovative heating technology. The 7100FP models are equipped with the patented Quadra-Fire combustion system, which promotes a cleaner burn and maximizes heat output. This system utilizes secondary combustion technology that burns off excess gases and particulates, resulting in a more environmentally friendly fire that emits fewer emissions compared to traditional wood-burning fireplaces.

Additionally, the 7100FP series includes advanced airflow designs that facilitate efficient heat distribution throughout the room. The adjustable air control allows users to easily regulate the burn rate and heat output, ensuring optimal comfort at any time. With a variety of trim options available, including the sleek black, traditional natural, and modern gold finishes, homeowners have the flexibility to choose a model that complements their interior decor.

Moreover, the 7100FP series is designed with user convenience in mind. For easy cleaning and maintenance, they include a removable ash pan feature. A glass viewing window is treated with a special coating, preventing soot buildup and allowing for uninterrupted views of the flames.

In terms of safety, the 7100FP units are equipped with a tempered glass door that is designed to withstand high temperatures, ensuring that the fireplace is safe for family gatherings. Overall, the Quadra-Fire 7100FP-BK-B, 7100FP-NL-B, and 7100FP-GD-B models seamlessly combine style, efficiency, and comfort, making them a top choice for those seeking a modern solution to home heating. With innovative technology and a commitment to performance, these fireplaces enhance any home’s ambiance while providing reliable warmth.