Quadra-Fire 7100FP-BK-B, 7100FP-NL-B warranty Fire Risk Asphyxiation Risk, Risk of Smoke Spillage

Page 16

R

7100FP EPA Woodburning Fireplace

WARNING

Fire Risk

Asphyxiation Risk

Do not draw outside combustion air from:

Wall, floor or ceiling cavity.

Enclosed space such as an attic or garage.

Close proximity to exhaust vents or chimneys.

Fumes or odor may result.

CAUTION

Risk of Smoke Spillage

Outside air inlet must be located to prevent blockage from:

Leaves

Snow/ice

Other debris

Blockage may cause combustion air starvation.

Handle Left - Closed

Handle Right - Open

Figure 16.2 Locating the Outside Air Control

Attic insulation shield must be used to keep insulation away from chimney.

Ceiling firestop on floor of attic.

3 ft min. from top of uppermost chimney section to air inlet.

Figure 16.1 Outside Air Inlet Locations

Page 16

433-1390D

September 7, 2007

Image 16
Contents 7100FP-BK-B 7100FP-GD-B 7100FP-NL-B Fire Risk007 7100FP EPA Woodburning FireplaceLocation on hang tag on right side of fireplace Table of Contents Appliance Certification Listing and Code ApprovalsMobile Home Approved 7100FP EPA Woodburning Fireplace Glass Specifications BTU & Efficiency SpecificationsDesign and Installation Considerations Getting StartedNegative Pressure Asphyxiation RiskSeptember 7 433-1390D 7100FP EPA Woodburning Fireplace Typical Fireplace System Typical Fireplace SystemInspect Fireplace and Components 7100FP EPA Woodburning Fireplace Tools and Supplies NeededFire Risk Explosion Risk Selecting Fireplace Location Framing and ClearancesModel #7100FP 7100FP EPA Woodburning Fireplace Clearances Clearances to Combustible MaterialsFrame the Fireplace Minimum Clearances to CombustiblesNon-Combustible Materials Combustible MaterialsElectrical Access and Wiring Diagram Suggestions7100FP EPA Woodburning Fireplace Construct the Chase MaterialsInstallation of Fireplace Install the Outside Air KitRisk of Smoke Spillage Fire Risk Asphyxiation RiskHandle Left Closed Handle Right Open Auxiliary Convection Air System Attic spaceConvection Air Lock 7100FP EPA Woodburning Fireplace Secure the Fireplace Position the FireplaceLevel the Fireplace Place the Protective Metal Hearth StripsChimney Assembly 7100FP EPA Woodburning Fireplace Chimney Requirements Chimney Termination Requirements7100FP EPA Woodburning Fireplace Using Offsets/Returns ExampleAssembling Chimney Sections for the SL- 300 Series Assembling Chimney SectionsInstall the Ceiling Firestops Installing Flex PipeDouble-check the Chimney Assembly Secure the ChimneyComplete the Enclosure Chimney Termination 2-10-03 RuleChimney Termination Requirements See Figures 26.1 Slanted RoofsInstall the Roof Flashing Install the Chimney Air Kit required in CanadaMark the Exit Point of the Roof Cut Out the Hole in the RoofConsult local codes for framing details 7100FP EPA Woodburning Fireplace Chase Top Install the Termination CapChase Top Framing For installations utilizing a Round Telescoping Termination Accessories Blower ReplacementBlower Replacement Instructions Blower Cord LocationDoor and Door Gasket Right Door7100FP EPA Woodburning Fireplace Heat Zone Kit Minimum Clearance to CombustiblesRun Length Cut Pipe 20 40 ft 6-12m 20 ft 3 6m 10 ft 1 3mBracket 7100FP EPA Woodburning Fireplace Timer Assembly Replacement Remove 2 screwsTimer Plate 7100FP EPA Woodburning FireplaceFinishing Hearth ExtensionModel # 7100FP Positioning the Protective Metal Hearth StripsOuter Can Flange Fascia Tile or Marble Combustible Floor Finishing Material Non-Combustible MaterialNon-Combustible Sealant Material Cardboard or Metal TemplateComplete installation Risk of Fire7100FP EPA Woodburning Fireplace Mantel Mantel SpecificationsGeneral Information Operating InstructionsKeep open during use 7100FP EPA Woodburning Fireplace Outside Air Clear Space Near the FireplaceFirescreen Glass Doors7100FP EPA Woodburning Fireplace Blower Operation Heat Zone OperationWood Fuel Hardwood vs. Softwood Minimum Clearance to Combustible 1 in mm from the B-VentSeasoning 7100FP EPA Woodburning Fireplace Moisture contentStoring Wood 7100FP EPA Woodburning Fireplace Starting a Fire Kindling or 1st stage 2nd stageFinal stage Slide Air ControlEmissions, follow these operating procedures 7100FP EPA Woodburning Fireplace Burning Guidelines OpacityBurn Rates For maximum operating efficiency with the lowestOverfiring Fire Safety Chimney FireUnderstanding Vent Problems TroubleshootingDraft Problems Factory-built Fireplaces Troubleshooting Diagnostic Question Possible Causes of Condition Solutions If I can’t get a good fire going, what am I doing wrong?Don’t get enough/any heat. What can I do about it? Maintenance and Servicing the Fireplace General MaintenanceGlass Replacement Glass CleaningDisposal of Ashes Fire Risk Injury Risk7100FP EPA Woodburning Fireplace Brick Replacement Use Part 832-2370 when ordering individual brick. ProVide brick dimension or copy this page, mark the desired Brick and take it to your authorized dealerMaintenance Task List Inspect Maintenance TasksReference Materials Fireplace Dimensions7100FP 7100FP EPA Woodburning Fireplace Chimney Components Catalog Description Catalog NoFS338 14-1/2 368 mm FS339 18-3/8 467 mm FS340 16-3/4 425 mm15-3/4 Glass Size 12-3/50 w x 15 h 7100FP EPA Woodburning Fireplace Fireplace Diagram 17 13 1514 27 25 2124Part Description 7100FP EPA Woodburning Fireplace Service PartsAlphabetical Order Accessories RIVNUT-REPAIRLifetime Warranty 7100FP EPA Woodburning Fireplace Warranty PolicyContact Information 7100FP EPA Certified Woodburning FireplaceDealer Telephone

7100FP-BK-B, 7100FP-GD-B, 7100FP-NL-B specifications

The Quadra-Fire 7100FP series, including the models 7100FP-BK-B, 7100FP-NL-B, and 7100FP-GD-B, represents an exceptional choice for homeowners seeking efficient and powerful heating solutions. These fireplaces are designed to provide warmth and ambiance while incorporating advanced technologies that enhance performance and ease of use.

One of the primary features of the 7100FP series is its large viewing area, which allows homeowners to enjoy the mesmerizing flames while increasing the aesthetic appeal of any living space. The generous size of the firebox ensures that it can accommodate sizable logs, providing longer burn times and requiring less frequent reloading. This feature is particularly beneficial for those who appreciate an extended, leisurely evening by the fire.

A hallmark of the Quadra-Fire brand is its innovative heating technology. The 7100FP models are equipped with the patented Quadra-Fire combustion system, which promotes a cleaner burn and maximizes heat output. This system utilizes secondary combustion technology that burns off excess gases and particulates, resulting in a more environmentally friendly fire that emits fewer emissions compared to traditional wood-burning fireplaces.

Additionally, the 7100FP series includes advanced airflow designs that facilitate efficient heat distribution throughout the room. The adjustable air control allows users to easily regulate the burn rate and heat output, ensuring optimal comfort at any time. With a variety of trim options available, including the sleek black, traditional natural, and modern gold finishes, homeowners have the flexibility to choose a model that complements their interior decor.

Moreover, the 7100FP series is designed with user convenience in mind. For easy cleaning and maintenance, they include a removable ash pan feature. A glass viewing window is treated with a special coating, preventing soot buildup and allowing for uninterrupted views of the flames.

In terms of safety, the 7100FP units are equipped with a tempered glass door that is designed to withstand high temperatures, ensuring that the fireplace is safe for family gatherings. Overall, the Quadra-Fire 7100FP-BK-B, 7100FP-NL-B, and 7100FP-GD-B models seamlessly combine style, efficiency, and comfort, making them a top choice for those seeking a modern solution to home heating. With innovative technology and a commitment to performance, these fireplaces enhance any home’s ambiance while providing reliable warmth.