Quadra-Fire 7100FP-BK-B 7100FP EPA Woodburning Fireplace Chimney Components, FS340 16-3/4 425 mm

Page 61

R

7100FP EPA Woodburning Fireplace

B. Chimney Components

The following drawings show the SL-300 Series chimney and fireplace components which may be safely used with this fireplace.

Catalog

Description

Catalog No.

Description

No.

 

 

 

CAK4A

Chimney Air Kit

CB876

Chimney Bracket

ID4

Insulated Duct / Outside Air

RF370

Roof Flashing - Flat to 6/12 Pitch

UD4

Uninsulated Duct / Outside Air

RF371

Roof Flashing - 6/12 to 12/12 Pitch

SL306

Chimney Section - 6 in. (152mm) Long

TR344

Round Termination Cap

SL312

Chimney Section - 12 in. (305mm) Long

TR342

Round Telescoping Termination Cap

SL318

Chimney Section - 18 in. (457mm) Long

ST375

Square Termination Cap

SL324

Chimney Section - 24 in. (610mm) Long

TS345

Square Termination Cap

SL336

Chimney Section - 36 in. (914mm) Long

CT35M

Chase Top (Sold in pack of 10)

SL348

Chimney Section - 48 in. (1219mm) Long

12966A

Mobile Home Thimble

SL3

Chimney Stabilizer

MH841

Mobile Home Thimble Extension, 20 in. (508 mm)

SL315

Chimney Offset / Return - 15°

HX4

MICORE Hearth Extension, 20 in. (508 mm) wide

SL330

Chimney Offset / Return - 30°

HEATZONE-WOOD

Heat Zone Kit

FS338

Firestop - Straight

SCR-433

Fire Screen

FS339

Firestop - 15°

TMP-433

Metal Face Template

FS340

Firestop - 30°

TV-TRK

Round Termination Top Vent Kit

AS8

Straight Attic Insulation Shield

9201

Simpson Dura-Plus Base Plate

JB877

Chimney Joint Band

 

 

A

INSULATED DUCT

42 in.

(10669 mm)

 

UNINSULATED DUCT

4 in.

4 in.

(102 mm)

(102 mm)

42in.

(10669 mm)

8 in.

 

 

 

10-1/2 in.

(203 mm)

 

 

 

(267 mm)

 

Chimney Sections

 

 

 

 

 

Catalog

 

 

A

B

No.

 

 

 

 

SL306

 

 

6 in.

4-3/4 in.

 

 

(152 mm)

(121 mm)

SL312

 

 

12 in.

10-3/4 in.

 

 

(305 mm)

(273 mm)

SL318

 

 

18 in.

16-3/4 in.

 

 

(457 mm)

(425 mm)

SL324

 

 

24 in.

22-3/4 in.

 

 

(610 mm)

(578 mm)

SL336

 

 

36 in.

34-3/4 in.

 

 

(914 mm)

(883 mm)

SL348

 

 

48 in.

46-3/4 in.

 

 

(1219 mm)

(1187 mm)

A = Actual Length

B = Effective length (length of chimney part after it has been snapped to another)

ID4UD4

 

 

 

12 in.

 

 

 

(305 mm)

 

 

A

24-5/8 in.

 

 

(625 mm)

 

 

 

 

 

 

27-3/8 in.

B

 

14-1/2 in.

(695 mm)

 

RF370 - Roof Flashing

 

 

 

 

(368 mm)

 

 

Flat to 6/12 Pitch

 

 

 

Firestop Spacer

 

 

Catalog No.

A

B

 

FS338

14-1/2” (368 mm)

 

FS339

15°

18-3/8” (467 mm)

12in.

FS340

30°

16-3/4” (425 mm)

 

 

 

(305 mm)

24-5/8 in.

(625 mm)

31 in.

RF371 - Roof Flashing 6/12 to 12/12 Pitch

September 7, 2007

433-1390D

Page 61

Image 61
Contents Fire Risk 7100FP-BK-B 7100FP-GD-B 7100FP-NL-B007 7100FP EPA Woodburning FireplaceLocation on hang tag on right side of fireplace Table of Contents Appliance Certification Listing and Code ApprovalsMobile Home Approved BTU & Efficiency Specifications 7100FP EPA Woodburning Fireplace Glass SpecificationsGetting Started Design and Installation ConsiderationsNegative Pressure Asphyxiation RiskSeptember 7 433-1390D Typical Fireplace System 7100FP EPA Woodburning Fireplace Typical Fireplace SystemInspect Fireplace and Components 7100FP EPA Woodburning Fireplace Tools and Supplies NeededFire Risk Explosion Risk Selecting Fireplace Location Framing and ClearancesModel #7100FP Clearances to Combustible Materials 7100FP EPA Woodburning Fireplace ClearancesMinimum Clearances to Combustibles Frame the FireplaceNon-Combustible Materials Combustible MaterialsSuggestions Electrical Access and Wiring DiagramMaterials 7100FP EPA Woodburning Fireplace Construct the ChaseInstall the Outside Air Kit Installation of FireplaceRisk of Smoke Spillage Fire Risk Asphyxiation RiskHandle Left Closed Handle Right Open Attic space Auxiliary Convection Air SystemConvection Air Lock Position the Fireplace 7100FP EPA Woodburning Fireplace Secure the FireplaceLevel the Fireplace Place the Protective Metal Hearth StripsChimney Assembly Chimney Termination Requirements 7100FP EPA Woodburning Fireplace Chimney RequirementsExample 7100FP EPA Woodburning Fireplace Using Offsets/ReturnsAssembling Chimney Sections Assembling Chimney Sections for the SL- 300 SeriesInstalling Flex Pipe Install the Ceiling FirestopsSecure the Chimney Double-check the Chimney AssemblyChimney Termination 2-10-03 Rule Complete the EnclosureChimney Termination Requirements See Figures 26.1 Slanted RoofsInstall the Chimney Air Kit required in Canada Install the Roof FlashingMark the Exit Point of the Roof Cut Out the Hole in the RoofConsult local codes for framing details 7100FP EPA Woodburning Fireplace Chase Top Install the Termination CapChase Top Framing For installations utilizing a Round Telescoping Termination Blower Replacement AccessoriesBlower Replacement Instructions Blower Cord LocationRight Door Door and Door GasketMinimum Clearance to Combustibles 7100FP EPA Woodburning Fireplace Heat Zone Kit20 ft 3 6m 10 ft 1 3m Run Length Cut Pipe 20 40 ft 6-12mBracket Remove 2 screws 7100FP EPA Woodburning Fireplace Timer Assembly Replacement7100FP EPA Woodburning Fireplace Timer PlateHearth Extension FinishingPositioning the Protective Metal Hearth Strips Model # 7100FPOuter Can Flange Fascia Tile or Marble Combustible Floor Non-Combustible Material Finishing MaterialNon-Combustible Sealant Material Cardboard or Metal TemplateRisk of Fire Complete installationMantel Specifications 7100FP EPA Woodburning Fireplace MantelGeneral Information Operating InstructionsKeep open during use Clear Space Near the Fireplace 7100FP EPA Woodburning Fireplace Outside AirFirescreen Glass DoorsHeat Zone Operation 7100FP EPA Woodburning Fireplace Blower OperationWood Fuel Hardwood vs. Softwood Minimum Clearance to Combustible 1 in mm from the B-VentSeasoning 7100FP EPA Woodburning Fireplace Moisture contentStoring Wood 7100FP EPA Woodburning Fireplace Starting a Fire 2nd stage Kindling or 1st stageFinal stage Slide Air Control7100FP EPA Woodburning Fireplace Burning Guidelines Opacity Emissions, follow these operating proceduresBurn Rates For maximum operating efficiency with the lowestChimney Fire Overfiring Fire SafetyUnderstanding Vent Problems TroubleshootingDraft Problems Factory-built Fireplaces Troubleshooting If I can’t get a good fire going, what am I doing wrong? Diagnostic Question Possible Causes of Condition SolutionsDon’t get enough/any heat. What can I do about it? General Maintenance Maintenance and Servicing the FireplaceGlass Cleaning Glass ReplacementDisposal of Ashes Fire Risk Injury RiskUse Part 832-2370 when ordering individual brick. Pro 7100FP EPA Woodburning Fireplace Brick ReplacementVide brick dimension or copy this page, mark the desired Brick and take it to your authorized dealerInspect Maintenance Tasks Maintenance Task ListReference Materials Fireplace Dimensions7100FP Catalog Description Catalog No 7100FP EPA Woodburning Fireplace Chimney ComponentsFS338 14-1/2 368 mm FS339 18-3/8 467 mm FS340 16-3/4 425 mm15-3/4 Glass Size 12-3/50 w x 15 h 17 13 1514 27 25 2124 7100FP EPA Woodburning Fireplace Fireplace DiagramPart Description 7100FP EPA Woodburning Fireplace Service PartsAlphabetical Order RIVNUT-REPAIR Accessories7100FP EPA Woodburning Fireplace Warranty Policy Lifetime WarrantyContact Information 7100FP EPA Certified Woodburning FireplaceDealer Telephone

7100FP-BK-B, 7100FP-GD-B, 7100FP-NL-B specifications

The Quadra-Fire 7100FP series, including the models 7100FP-BK-B, 7100FP-NL-B, and 7100FP-GD-B, represents an exceptional choice for homeowners seeking efficient and powerful heating solutions. These fireplaces are designed to provide warmth and ambiance while incorporating advanced technologies that enhance performance and ease of use.

One of the primary features of the 7100FP series is its large viewing area, which allows homeowners to enjoy the mesmerizing flames while increasing the aesthetic appeal of any living space. The generous size of the firebox ensures that it can accommodate sizable logs, providing longer burn times and requiring less frequent reloading. This feature is particularly beneficial for those who appreciate an extended, leisurely evening by the fire.

A hallmark of the Quadra-Fire brand is its innovative heating technology. The 7100FP models are equipped with the patented Quadra-Fire combustion system, which promotes a cleaner burn and maximizes heat output. This system utilizes secondary combustion technology that burns off excess gases and particulates, resulting in a more environmentally friendly fire that emits fewer emissions compared to traditional wood-burning fireplaces.

Additionally, the 7100FP series includes advanced airflow designs that facilitate efficient heat distribution throughout the room. The adjustable air control allows users to easily regulate the burn rate and heat output, ensuring optimal comfort at any time. With a variety of trim options available, including the sleek black, traditional natural, and modern gold finishes, homeowners have the flexibility to choose a model that complements their interior decor.

Moreover, the 7100FP series is designed with user convenience in mind. For easy cleaning and maintenance, they include a removable ash pan feature. A glass viewing window is treated with a special coating, preventing soot buildup and allowing for uninterrupted views of the flames.

In terms of safety, the 7100FP units are equipped with a tempered glass door that is designed to withstand high temperatures, ensuring that the fireplace is safe for family gatherings. Overall, the Quadra-Fire 7100FP-BK-B, 7100FP-NL-B, and 7100FP-GD-B models seamlessly combine style, efficiency, and comfort, making them a top choice for those seeking a modern solution to home heating. With innovative technology and a commitment to performance, these fireplaces enhance any home’s ambiance while providing reliable warmth.