Samsung AQ09NLNSER, AQ09NLXSER manual ÊÂÁ͇ ÚÛ·ÓÍ/ ì‰ÎËÌÂÌË ÚÛ·ÓÔÓ‚Ó‰‡, ‰Îëìâì

Page 27

ìÒÚ‡Ìӂ͇ ÛÒÚÓÈÒÚ‚‡

êÂÁ͇ ÚÛ·ÓÍ/ ì‰ÎËÌÂÌË ÚÛ·ÓÔÓ‚Ó‰‡

ÇÍÓÏÔÎÂÍÚ ÔÓÒÚ‡‚ÍË ÍÓ̉ˈËÓÌÂ‡ ‚ıÓ‰flÚ ÚÛ·ÍË ‰ÎËÌÓÈ

5 ÏÂÚÓ‚ (Ì ‚Ó ‚ÒÂı ÏÓ‰ÂÎflı). ÖÒÎË ÌÂÓ·ıÓ‰ËÏÓ, ˝ÚË ÚÛ·ÍË ÏÓ„ÛÚ ·˚Ú¸:

ì‰ÎËÌÂÌ˚ χÍÒËÏÛÏ ‰Ó 15 ÏÂÚÓ‚

ìÍÓÓ˜ÂÌ˚ ‰Ó ÌÛÊÌÓÈ ‰ÎËÌ˚

ÖÒÎË Ú·ÛÂχfl ‰ÎË̇ ÚÛ·ÓÍ Ô‚˚¯‡ÂÚ 5 ÏÂÚÓ‚

ëÓ‰ËÌËÚÂθÌ˚È Í‡·Âθ Ú‡ÍÊ ‰ÓÎÊÂÌ ·˚Ú¸

Û‰ÎËÌÂÌ

Ç ÍÓÌÚÛ ı·‰‡„ÂÌÚ‡ ‰ÓÎÊÌÓ ·˚Ú¸ Á‡Ô‡‚ÎÂÌÓ ‰ÓÔÓÎÌËÚÂθÌÓ ÍÓ΢ÂÒÚ‚Ó ı·‰‡„ÂÌÚ‡, ‰Îfl ˜Â„Ó Ó·‡ÚËÚÂÒ¸ Í ÒÔˆˇÎËÒÚÛ ÔÓ ÛÒÚ‡ÌÓ‚Í ÍÓ̉ˈËÓÌÂÓ‚; ‚ ÔÓÚË‚ÌÓÏ ÒÎÛ˜‡Â ÍÓÏ̇ÚÌ˚È ·ÎÓÍ ÏÓÊÂÚ Á‡ÏÂÁÌÛÚ¸

1 ì·Â‰ËÚÂÒ¸ ‚ ÚÓÏ, ˜ÚÓ Û ‚‡Ò ËϲÚÒfl ‚Ò ÌÛÊÌ˚ ËÌÒÚÛÏÂÌÚ˚ (ÚÛ·ÓÂÁ, ‡Á‚ÂÚ͇, ÔËÒÔÓÒÓ·ÎÂÌË ‰Îfl ‡Á‚‡Î¸ˆÓ‚ÍË Ë ÚÛ·Ó‰ÂʇÚÂθ).

2 ÖÒÎË ‚˚ ıÓÚËÚ ÛÍÓÓÚËÚ¸ ÚÛ·ÍË, ÓÚÂʸÚ Ëı Ò ÔÓÏÓ˘¸˛ ÚÛ·ÓÂÁ‡, Ó·ÂÒÔ˜˂ ÔË ˝ÚÓÏ, ˜ÚÓ·˚ ÚÓˆ ÓÚÂÁ‡ÌÌÓÈ ÚÛ·ÍË ·˚Î ÔÓ‰ Û„ÎÓÏ 90°Í ÚÛ·ÍÂ Ë ÛÍÓ‚Ó‰ÒÚ‚ÛflÒ¸ ÌËÊÂÔ˂‰ÂÌÌ˚ÏË ËÒÛÌ͇ÏË, ̇ ÍÓÚÓ˚ı Ô˂‰ÂÌ˚ ÔËÏÂ˚ Ô‡‚ËθÌÓ„Ó Ë ÌÂÔ‡‚ËθÌÓ„Ó ÓÚÂÁ‡ ÚÛ·ÓÍ.

90O

äÓÒÓÈ ÒÂÁ

çÂÓ‚ÌÓÒÚË

á‡ÛÒÂ̈˚

O

x

x

x

3ÑÎfl Ô‰ÓÚ‚‡˘ÂÌËfl ÛÚ˜ÂÍ ı·‰‡„ÂÌÚ‡ Û‰‡ÎËÚ ‚Ò Á‡ÛÒÂ̈˚ Ò ÓÚÂÁ‡ÌÌ˚ı ÚÓˆÓ‚ ÚÛ·ÓÍ Ò ÔÓÏÓ˘¸˛ ‡Á‚ÂÚÍË.

4燉Â̸Ú ̇ÍˉÌÛ˛ „‡ÈÍÛ Ì‡ ÚÛ·ÍÛ Ë ‡Á‚‡Î¸ˆÛÈÚ ÍÓ̈ ÚÛ·ÍË.

ç‡ÛÊÌ˚È ‰Ë‡ÏÂÚ(D)

ÉÎÛ·ËÌ (A)

6,35

ÏÏ

1,3 ÏÏ

9,52

ÏÏ

1,8 ÏÏ

12,70

ÏÏ

2,0 ÏÏ

5èÓ‚Â¸Ú Ô‡‚ËθÌÓÒÚ¸ ‡Á‚‡Î¸ˆÓ‚ÍË, ÛÍÓ‚Ó‰ÒÚ‚ÛflÒ¸

ÌËÊÂÔ˂‰ÂÌÌ˚ÏË ËÒÛÌ͇ÏË, ̇ ÍÓÚÓ˚ı Ô˂‰ÂÌ˚ ÔËÏÂ˚ ÌÂÔ‡‚ËθÌÓÈ ‡Á‚‡Î¸ˆÓ‚ÍË.

x

x

x

x

ëÓ ÒÍÓÒÓÏ

èÓ‚ÂʉÂÌ̇fl

í¢ËÌ˚

çÂ‡‚ÌÓÏÂ̇fl

 

ÔÓ‚ÂıÌÓÒÚ¸

 

ÚÓ΢Ë̇

6 Ç˚‡‚ÌËÚ ÚÛ·˚, ÍÓÚÓ˚ ·Û‰ÂÚ ÔÓ‰ÒÓ‰ËÌflÚ¸, Á‡ÍÛÚËÚ ‡Ò¯Ëfl˛˘ËÂÒfl „‡ÈÍË Ò̇˜‡Î‡ ‚Û˜ÌÛ˛ ‡ ÔÓÚÓÏ Ò ÔÓÏÓ˘¸˛ Íβ˜‡, ÔË·„‡fl ÒÎÂ‰Û˛˘ËÈ ÏÓÏÂÌÚ.

ç‡ÛÊÌ˚È ‰Ë‡ÏÂÚ

åÓÏÂÌÚ (Í„Ù•ÒÏ)

6,35

ÏÏ

140~170

9,52

ÏÏ

250~280

12,70

ÏÏ

380~420

7ÅÓΠÔÓ‰Ó·Ì˚ ҂‰ÂÌËfl Ó ÚÓÏ, Í‡Í ÔÓ‰ÒÓ‰ËÌflÚ¸ ÚÛ·ÍË Í

̇ÛÊÌÓÏÛ ·ÎÓÍÛ Ë Í‡Í Û‰‡ÎËÚ¸ ‚ÓÁ‰Ûı ËÁ ÚÛ·ÓÔÓ‚Ó‰‡ ÒÏÓÚËÚ ̇ ÒÚ. 12.

R-11

Image 27
Contents Cooling and Heating AQ12F Series AQ09N Series AQ12N SeriesSafety Precautions Contents Indoor Unit Deciding on Where to Install the Air ConditionerPreparing the Installation Air Conditioner and Accessories Accessories in the Indoor Unit CaseAccessories in the Outdoor Unit Case Fixing the Installation Plate Purging the UnitThen follow Steps Connecting the Assembly Cable Installing and Connecting the Outdoor Unit Drain Hose Installing and Connecting the Indoor Unit Drain HoseTorque kgfcm Installing and Connecting the Indoor Unit Assembly PipingDepth a Cutting/Extending the PipingConnecting Up and Purging the Circuit Outer Diameter Torque kgfcmIf you have used Then To check for gas leaks on Then, using a leak detector Check Performing Leak TestsPlacing the Indoor Unit in Position Fixing the Outdoor Unit in Position Checking and Testing OperationsExplaining Operations to the Owner Electronics ÊìäéÇéÑëíÇé èé ìëíÄçéÇäÖ ÅÂ˚ è‰ÓÒÚÓÓÊÌÓÒÚË ËÓ‰ÂʇÌË ÄÓÏ̇ÚÌ˚È ·ÎÓÍ ˚·Ó ÏÂÒÚ‡ ‰Îfl ÛÒÚ‡ÌÓ‚ÍË ÍÓ̉ˈËÓÌÂ‡300 ÏÏ ËÎË ·ÓΠ125 ÏÏ ËÎË ·ÓΠÊËθÌ˚È ÄÓ̉ˈËÓÌÂ Ë ÔË̇‰ÎÂÊÌÓÒÚË Í Ìâïû12068 ‡‡ÍÚÂËÒÚËÍË Í‡·ÂÎfl ÔËÚ‡ÌËfl ÈÓ‰Íβ˜ÂÌË ÒÓ‰ËÌËÚÂθÌÓ„Ó Í‡·ÂÎflÌÒÚ‡Ìӂ͇ Ë èÓ‰ÒÓ‰ËÌÂÌË ÑÂ̇ÊÌÓ„Ó ò·̄‡ äÓÏ̇ÚÌÓ„Ó ÅÎÓ͇ ÅÓÌÚ‡Ê Ë ÔÓ‰ÒÓ‰ËÌÂÌË ‰Â̇ÊÌÓ„Ó ¯Î‡Ì„‡ Í ÍÓÏ̇ÚÌÓÏÛ ·ÎÓÍÛÅÓÌÚ‡Ê Ë ÔÓ‰ÒÓ‰ËÌÂÌË ÚÛ·ÓÔÓ‚Ó‰‡ Í ÍÓÏ̇ÚÌÓÏÛ ·ÎÓÍÛ ‰ÎËÌÂÌ ÊÂÁ͇ ÚÛ·ÓÍ/ ì‰ÎËÌÂÌË ÚÛ·ÓÔÓ‚Ó‰‡‡ÛÊÌ˚È ÄÓÏ̇ÚÌ˚È ÌÒÚ‡Ìӂ͇ ÍÓÏ̇ÚÌÓ„Ó ·ÎÓ͇ ‚ Ìûêìóï Ôóîóêâìëë Ó‚Â͇ ÓÚÒÛÚÒÚ‚Ëfl ÛÚ˜ÍË „‡Á‡Ó‚ÂÍË Ë ÔÓ·Ì˚È Ôûòí ‡ÍÂÔÎÂÌË ç‡ÛÊÌÓ„Ó ÅÎÓ͇ÀÌÒÚÛÍÚ‡Ê ÔÓθÁÓ‚‡ÚÂÎfl AQ07X*RIM27212 1/19/07 1121 AM
Related manuals