Condensate Piping and Trap with Optional Condensate Neutralizer
6.1Condensate Neutralization System (optional)
Although only slightly acidic
1.Follow the steps 1 through 4 in the Condensate Drain, Trap & Disposal section above.
2.Locate the Condensate Neutralization System in the condensate piping, as shown in the FIELD INSTALLED CONDENSATE DIAGRAM above.
3.Position with removable crushed limestone
4.For proper operation, the water heater condensate outlet must be plumbed with CPVC plastic pipe to the lowest fitting of the Condensate Neutralization System, connecting to the “INLET” as shown in the graphic below.
5.Keep the Condensate Neutralization System closed at all times, except for maintenance.
Optional Condensate Neutralization System
WARNING: Keep the Condensate Neutralization System closed at all times the appliance is operating. The system must remain closed to prevent hazardous products combustion from continually enter the room. Failure to keep the Condensate Neutralization System closed can cause property damage, personal injury, exposure to hazardous materials or loss of life.
14