Marley Engineered Products 763, 761 important safety instructions Description, Unpacking, Tools

Page 1

READ AND SAVE THESE INSTRUCTIONS

MODELS 761, 763, 765, 7100, 7130, 7150,

8090 & 8100 FANS

MODELS 768IC, 770IC, 7100L, 7150L, 7100FL, 7150FL,

8090L & 8100L FAN/LIGHTS

MODELS 7100H, 7100FLH, 7150H & 7150FLH FANS & FAN/LIGHTS with HUMIDITY SENSOR

DESCRIPTION

The FAN and FAN/LIGHT models listed in these instructions are intended for use in bathrooms. However, they can also be used in other areas where ventilation is required. These units are approved for installation in the ceiling above a bathtub or shower stall only when connected to a U.L. Listed GFCI pro- tected branch circuit. ALL FAN/LIGHT models are U.L. Listed Type I.C. (Inherently Protected) for installation in insulated ceil- ings.

6.When cutting or drilling into wall or ceiling, do not damage

electrical wiring or other hidden utilities.

7.Ducted fans must always be vented to the outdoors.

8.If this unit is installed over a tub or shower, it must be marked as appropriate for the application. See product label.

9.NEVER place a switch where it can be reached from a tub or shower.

10.CAUTION: For General Ventilation Use Only! Do not use to exhaust hazardous or explosive materials or vapors.

11.Not for use in kitchens.

UNPACKING

Unpack carefully. If there are missing components or hidden damage, immediately contact your distributor or the delivering carrier concerning discrepancies.

IMPORTANT SAFETY INSTRUCTIONS

WARNING:

TO REDUCE RISK OF FIRE, ELECTRICAL SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.Do not use this fan with any Solid-State speed control device.

2.Use this unit only in the manner intended by the manufa- cturer. If you have any questions, contact the manufacturer.

3.Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally.

4.Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.

5.Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating and Air Conditioning Engineers (ASHRAE), and the local code authorities.

TOOLS

Installation of your Marley Engineered Products fan is easy. No special technical knowledge is needed; only a few ordinary tools are required:

Screwdriver

Hammer

Saber saw, Keyhole saw, or Jig saw

Electric drill with bit

Wire cutters

Wire stripper

Wire nuts and general electrical supplies

Safety glasses

Ruler and straight edge

All hand tools should be insulated. Power tools should display the UL Listing Mark.

Image 1
Contents Description Important Safety InstructionsUnpacking ToolsModels Models 761, 763, 765, 768IC, and 770IC NEW Home InstallationRoof CAP Round Roundduct Duct Wall NEW Home Installation Installation in Existing HomesModels Requirements and Adjustments for Humidity Sensing Units only Specifications AccessoriesDesembalaje DescripcionHerramientas Modelos Modelos 761, 763, 765, 768IC, Y 770IC Instalacion EN UNA Casa Nueva¡ATENCION Instalacion EN UNA Casa Nueva Instalacion EN Casas ExistentesModelos 7100, 7130 7100H, 7150H 8090 Y 279 mm 25 mm Especificaciones AccesoriosOutils DéballageSchéma 2 Modèles Schéma Nouvelle Installation DomestiqueSchéma Nouvelle Installation Domestique Ancienne Installation DomestiqueModèles Schéma 10 Schéma Spécifications Accessoires