Marley Engineered Products 765, 761, 763 Installation in Existing Homes, NEW Home Installation

Page 5

INSTALLATION IN EXISTING HOMES

(MODELS: 761, 763, 765, 768IC & 770IC)

1.Review the section: “New Home Installation” and follow instructions where applicable.

2.Refer to wiring diagrams for wiring and Fig. 6 & 7 for duct work.

3.Determine location of ventilator, remembering that the housing must be installed next to a joist.

4.Drill a small hole in ceiling in proposed location, then locate this hole in the attic.

5.In the attic, position housing against ceiling joist and over drilled hole. Using the housing as a template, mark ceiling for cutout. Make cutout on this line.

6.Remainder of installation is the same as steps 1 through 10 under “New Home Installation” above. Cracks between housing and ceiling may be plastered or caulked.

NEW HOME INSTALLATION

(MODELS: 7100, 7130, 7150, 8090, 8100, 7100L,

7150L, 7100H, 7100FLH, 7150H, 7150FLH, 7100FL, 7150FL, 8090L & 8100L)

1.Remove grille assembly from carton and set aside until needed. Remove reflector assembly from blower unit (MODELS: 7100L, 7100FLH, 7150FLH, 7150L, 7100FL, 7150FL, 8090L & 8100L) by pulling plug from receptacle, loosen mounting screws and remove through keyhole slot. Pull timer plug from recetpacle if applicable. See Fig. 9.

2.Loosen three screws securing blower unit to housing and slide it toward outlet box. Carefully lift and tilt blower unit and remove from housing. Pull motor plug from receptacle. Pull humidity sensor plug from recetpacle if applicable. See Figs. 8 & 9.

3.Remove outlet box cover by removing mounting screw. Retain cover and screw for reinstallation. Remove desired knockout from housing.

4.If DUCT ADAPTER is already attached to housing, disregard Item #4. If not proceed as follows! Attach DUCT ADAPTER to housing by first hooking mounting flange over edge of air discharge opening. Pivot duct adapter insuring (2) aligning tabs are inside opening and align (2) locking tabs with small rectangular holes. Press tabs firmly into holes to lock. See Fig. 3. Remove tape securing damper.

NOTE: The attachment of the duct adapter to the housing may be reinforced, if desired, by installing a #8AB screw through the oblong hole in the duct adapter and the small round hole in the housing.

5.Insert (4) mounting brackets with angles pointing away from housing. In approximate location between joist where housing will be located, drive (2) nails (4D or 6D) 1” from bottom of joist, 11” apart leaving 1/4” of nail projecting. Position one set of mounting brackets over nails and drop into place. Extend the remaining mounting brackets to the adjacent joist and repeat nailing procedure. Finish driving nails and adjust housing between ceiling joist. See Fig. 10.

6.Run 120V A C, 60 Hz power cables from wall switch/switches to appropriate knockout in housing. Use a BX or Romex connector. (Refer to wiring diagram designated for the model being installed.) Connect cables from wall switch/switches to receptacle wires using approved wire connectors. Connect ground wire to green screw or lead in outlet box. Install outlet box cover and secure with screw provided.

7.Run four inch duct from discharge outlet to roof jack or wall cap. See Figs. 6 & 7.

IMPORTANT: Be sure nothing obstructs the discharge of the vent. Take precautions to insure that insulation does not get into ductwork or fan discharge opening, and damper opens and closes freely.

8.Push humidity sensor plug into receptacle, if applicable. Push blower motor plug into receptacle and carefully replace blower unit. Reverse procedure as noted. Tighten screws securely. See Figs. 8 & 9.

9.Insert timer plug into humidity sensor receptacle, if applicable. Insert lamp plug of reflector assembly into lamp receptacle on the outlet box. Align keyhole slot on reflector

assembly bracket over screw on blower unit and slide into place. Insure that protrusion in bracket aligns with hole in blower assembly and tighten screw. Install 100 watt (maximum) type A-19 bulb and a 7 1/2 watt candelabra base C-7 bulb. (MODELS: 7100L, 7150L, 8090L & 8100L only.) On fluorescent models 7100FL, 7150FL, 7100FLH and

7150FLH install two of the following 13 watt quad-tube compact fluorescent lamps / 2 Pin:

Osram/Sylvania

Panasonic

Philips

General Electric

CF13DD/841

FQ13E41.u/2

PL-C13W/41/USA

F13DBX23T4/SPX41

10. Squeeze spring on plastic grille and insert into tabs located in housing. See Figs. 8 & 9. Press grille firmly into place.

Image 5
Contents Description Important Safety InstructionsUnpacking ToolsModels Models 761, 763, 765, 768IC, and 770IC NEW Home InstallationRoof CAP Round Roundduct Duct Wall NEW Home Installation Installation in Existing HomesModels Requirements and Adjustments for Humidity Sensing Units only Specifications AccessoriesHerramientas DescripcionDesembalaje Modelos Modelos 761, 763, 765, 768IC, Y 770IC Instalacion EN UNA Casa Nueva¡ATENCION Instalacion EN UNA Casa Nueva Instalacion EN Casas ExistentesModelos 7100, 7130 7100H, 7150H 8090 Y 279 mm 25 mm Especificaciones AccesoriosOutils DéballageSchéma 2 Modèles Schéma Nouvelle Installation DomestiqueSchéma Nouvelle Installation Domestique Ancienne Installation DomestiqueModèles Schéma 10 Schéma Spécifications Accessoires