Procom MN100TBA, MN100HBA, MN060HBA installation manual Instructions, Procedure, GAS to Appliance

Page 11

OPERATING YOUR HEATER

Manual Control Models

nLIGHTINGn

INSTRUCTIONS

1.STOP! Read the safety information on the side of

heater.

2.Check that gas supply to heater is on.

3.Push in gas control knob

slightly and turn clockwise to the OFF position.

4.Wait five (5) minutes to clear out any air. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information on the side of the heater. If you do not smell gas, go to the next step.

5.Push in gas control knob

slightly and turn

counterclockwise to “PILOT/IGN” and depress for five(5) seconds

Set control knob to desired heating position.

NOTE: Both HIGH and LOW are locked positions. You must press in control knob before turning it from these positions.

Figure 16 -1- Control Knob In The OFF Position (MN060HBA)

nTO TURN OFFn

GAS TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise

to the OFF position.

2.Turn off all electric power to the appliance if service is to be performed.

Shutting Off Burner Only (Pilot Stays Lit)

Turn control knob clockwise to the PILOT/IGN position.

nMANUAL LIGHTINGn

PROCEDURE

1.

Remove lower front panel(see

 

Figure 7 page 7).

2.

Follow steps 1 through 5

 

under Lighting Instructions.

3.

With control knob pressed in,

 

strike match. Hold match to

 

pilot until pilot lights.

4.

Keep control knob pressed in

 

for 30 seconds after lighting

NOTE: The first time that the heater is operated after connecting the gas supply , the control knob should be depressed for about thirty (30) seconds. This will allow air to bleed from the gas system.

6.With control knob pressed in, push down and release the ignitor button. This will light pilot. If needed, keep pressing ignitor button until pilot lights.

7.Keep control knob depressed for ten (10) seconds after lighting pilot. If pilot goes out, repeat steps 5,6 and 7.

8.To select the desired heating level, partially press down the control knob slightly and rotate

counterclockwise . Release the downward pressure on the knob while continuing to turn until the knob locks at the desired setting position. Do not operate between locked positions.

Figure 16-2 - Control Knob in The OFF Position (MN100HBA&MN100TBA)

Figure 17 - Pilot

CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

pilot. After 30 seconds, release

control knob. Follow step 8

under Lighting Instructions.

5. Replace lower front panel.

1 1

Image 11
Contents MN060HBA MN100HBA MN100TBA OWNER’S Operation and Installation ManualSafety Information Product Features Determining if you have a Confined or Unconfined Space Fresh AIR for Combustion VentilationProviding Adequate Ventilation Determining FRESH-AIR Flow for Heater LocationVentilation Air from Inside Building AIR for Combustion Ventilation Ventilation AIRLocating Heater InstallationInstallation Needs Ventilation AIRInstalling Thermostat Sensing Bulb InstallationPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewTypical Inlet Pipe Diameters Connecting to GAS SupplyRead Before Lighting NFOR Your SAFETYnChecking GAS Connections NON-THERMOSTAT ModelGAS to Appliance ProcedureInstructions To Appliance Operating Your HeaterThermostat Model Read Before LightingOperating Heater Cleaning MaintenanceObserved Problem Possible Cause Remedy TroubleshootingPossible Cause Remedy Observed ProblemHeater produces unwanted odors Specifications MN060HBA Illustrated Parts BreakdownKEY Description Parts List MN060HBAMN100HBA Parts List MN100HBA MN100TBA KEY Description QTY Parts List MN100TBA
Related manuals
Manual 24 pages 28.45 Kb

MN100TBA, MN060HBA, MN100HBA specifications

Procom has made a significant mark in the world of communications technology with its line of radio communication equipment, including the MN060HBA, MN100TBA, and MN100HBA models. These devices are designed to enhance communication capabilities across various sectors, offering advanced features and technologies that cater to both professional and industrial needs.

The Procom MN060HBA is a highly versatile handheld radio that operates within the 6 MHz bandwidth. Known for its robust build quality, the MN060HBA supports multiple frequency ranges, enabling users to communicate across a broad spectrum. It's equipped with a powerful battery that ensures extended operational time, making it suitable for long-term use in demanding environments. Additional features include a user-friendly interface, programmable channels, and encryption capabilities, providing secure communication for mission-critical applications.

Next, the MN100TBA model stands out with its unique tri-band frequency capabilities, allowing seamless communication across different bands. This model is particularly beneficial for users who require flexibility in their communication methods. The MN100TBA incorporates advanced noise-canceling technology, ensuring clear audio even in noisy surroundings. Its rugged design adheres to IP standards, offering resistance against dust and moisture, making it ideal for outdoor operations. Moreover, the device is equipped with a high-resolution display, allowing users to access information and settings quickly.

On the other hand, the MN100HBA is engineered for high-performance applications, featuring dual-band operation that strikes a perfect balance between range and clarity. This model is tailored for professional use, boasting superior audio quality and a comprehensive suite of features, including GPS for location tracking and emergency alerts. The MN100HBA also supports various modulation schemes, delivering flexibility depending on operational needs. With a rechargeable battery and efficient power management system, users can depend on this model for extended periods, even during intensive use.

In summary, Procom’s MN060HBA, MN100TBA, and MN100HBA represent the forefront of radio communication technology. Each model offers unique features tailored to specific user requirements, including durability, multi-band operation, and advanced audio quality. These devices are designed to stand the test of time, offering reliable performance in challenging environments, thereby making them essential tools for professionals in diverse industries.