Procom MN100TBA, MN100HBA, MN060HBA Troubleshooting, Observed Problem Possible Cause Remedy

Page 14

TROUBLESHOOTING

Note : All

troubleshooting

WARNING: Only a qualified

items are listed in order of

service person should service and

operation.

 

repair heater.

OBSERVED PROBLEM

POSSIBLE CAUSE

CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit.

REMEDY

When ignitor button is pressed in, there is no spark at ODS/pilot.

When ignitor button is pressed in, there is a spark at ODS/pilot but no ignition.

ODS/pilot lights but flame goes out when control knob is released.

1.Ignitor electrode is positioned wrong.

2.Ignitor electrode is broken.

3.Ignitor electrode is not connected to ignitor cable.

4.Ignitor cable is pinched or wet.

5.Broken ignitor cable.

6.Bad piezo ignitor.

1 . G a s s u p p l y t u r n e d o f f o r equipment shutoff valve is closed.

2.Control knob not fully pressed in while pressing ignitor button.

3.Air in gas lines when installed.

4.ODS/pilot is clogged.

5.Gas regulator setting is not cor- rect

6.Control knob not in PILOT position.

1.Control knob is not fully pressed in.

2.Control knob is not pressed in long enough.

3.Equipment shutoff valve is not fully open.

4.Thermocouple connection is loose at control valve.

5.Thermocouple damaged.

6.Control valve damaged.

1.Replace ignitor.

2.Replace ignitor.

3.Reconnect ignitor cable.

4.Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry.

5.Replace ignitor cable.

6.Replace piezo ignitor.

1.Turn on gas supply or open equipment shutoff valve.

2.Fully press in control knob while pressing ignitor button.

3.Continue holding down control knob. Repeat igniting operation until air is removed.

4.Clean ODS/pilot (see Cleaning and Maintenance Page 13) or replace ODS/pilot assembly.

5.Replace gas regulator.

6.Turn control knob to PILOT position.

1.Press in control knob fully.

2.After ODS/pilot lights, keep control knob pressed in 30 seconds.

3.Fully open equipment shutoff valve.

4.Hand tighten until snug, then tighten 1/4 turn more.

5.Replace thermocouple.

6.Contact Dealer or PRO-COM.

1 4

Image 14
Contents OWNER’S Operation and Installation Manual MN060HBA MN100HBA MN100TBASafety Information Product Features Determining FRESH-AIR Flow for Heater Location Fresh AIR for Combustion VentilationProviding Adequate Ventilation Determining if you have a Confined or Unconfined SpaceAIR for Combustion Ventilation Ventilation AIR Ventilation Air from Inside BuildingVentilation AIR InstallationInstallation Needs Locating HeaterInstallation Installing Thermostat Sensing BulbInstalling Bottom Mounting Screw Placing Heater On Mounting BracketConnecting to GAS Supply Typical Inlet Pipe DiametersNON-THERMOSTAT Model NFOR Your SAFETYnChecking GAS Connections Read Before LightingGAS to Appliance ProcedureInstructions Read Before Lighting Operating Your HeaterThermostat Model To ApplianceCleaning Maintenance Operating HeaterTroubleshooting Observed Problem Possible Cause RemedyObserved Problem Possible Cause RemedyHeater produces unwanted odors Specifications Illustrated Parts Breakdown MN060HBAParts List MN060HBA KEY DescriptionMN100HBA Parts List MN100HBA MN100TBA Parts List MN100TBA KEY Description QTY
Related manuals
Manual 24 pages 28.45 Kb

MN100TBA, MN060HBA, MN100HBA specifications

Procom has made a significant mark in the world of communications technology with its line of radio communication equipment, including the MN060HBA, MN100TBA, and MN100HBA models. These devices are designed to enhance communication capabilities across various sectors, offering advanced features and technologies that cater to both professional and industrial needs.

The Procom MN060HBA is a highly versatile handheld radio that operates within the 6 MHz bandwidth. Known for its robust build quality, the MN060HBA supports multiple frequency ranges, enabling users to communicate across a broad spectrum. It's equipped with a powerful battery that ensures extended operational time, making it suitable for long-term use in demanding environments. Additional features include a user-friendly interface, programmable channels, and encryption capabilities, providing secure communication for mission-critical applications.

Next, the MN100TBA model stands out with its unique tri-band frequency capabilities, allowing seamless communication across different bands. This model is particularly beneficial for users who require flexibility in their communication methods. The MN100TBA incorporates advanced noise-canceling technology, ensuring clear audio even in noisy surroundings. Its rugged design adheres to IP standards, offering resistance against dust and moisture, making it ideal for outdoor operations. Moreover, the device is equipped with a high-resolution display, allowing users to access information and settings quickly.

On the other hand, the MN100HBA is engineered for high-performance applications, featuring dual-band operation that strikes a perfect balance between range and clarity. This model is tailored for professional use, boasting superior audio quality and a comprehensive suite of features, including GPS for location tracking and emergency alerts. The MN100HBA also supports various modulation schemes, delivering flexibility depending on operational needs. With a rechargeable battery and efficient power management system, users can depend on this model for extended periods, even during intensive use.

In summary, Procom’s MN060HBA, MN100TBA, and MN100HBA represent the forefront of radio communication technology. Each model offers unique features tailored to specific user requirements, including durability, multi-band operation, and advanced audio quality. These devices are designed to stand the test of time, offering reliable performance in challenging environments, thereby making them essential tools for professionals in diverse industries.