Procom MN100HBA, MN060HBA, MN100TBA Ventilation AIR, Installation, Locating Heater, Check GAS Type

Page 6

VENTILATION AIR

Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or duels: You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor.

Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code NFPA 54/ANS Z223.1, Section 5.3. Air for Combustion and Ventilation for required size of ventilation grills or ducts. IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a

Figure 3 -Ventilation Air from Outdoorsthermostat-controlled power vent. Heated air entering the attic will activate

the power vent.

INSTALLATION

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

WARNING: A qualified service person must install heater. Follow all local codes.

CHECK GAS TYPE

Use only natural gas. If your gas supply is not natural, do not install heater. Call dealer where you bought heater for proper type heater.

INSTALLATION NEEDS

Before installing heater, make sure you have the items listed below:

piping (check local codes)

sealant (resistant to natural gas)

equipment shutoff valve*

ground joint union

test gauge connection*

sediment trap

tee joint

pipe wrench

*A CSA/AGA design-certified equip- ment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA/AGA design cer- tified equipment shutoff valve from your dealer. See Accessories, page 17.

LOCATING HEATER

This heater is designed to be m o u n t e d o n a w a l l . For convenience and efficiency, install heater

where there is easy access for operation, inspection, and service

in coldest part of room

CAUTION: If you install the heater in a home garage

heater pilot and burner must be at least 18 inches above floor.

locate heater where moving vehicle will not hit it.

WARNING: Never install the heater

in a bathroom (Models MN100HBA and MN100TBA, only MN060HBA is allowed in bathroom. Check local codes.)

in a recreational vehicle.

where curtains, furniture, clothing, or other flammable ob- jects are less than 36 inches from the front, top, or sides of the heater.

as a fireplace insert.

in high traffic areas.

in windy or drafty areas.

When the heater is installed in Bathrooms,do not use flammable products such as aerosol hair spray, foot spary or any product that contains flammable vapors and keep towels away from heater.(only MN060HBA is allowed in a bathroom.)

CAUTION: This heater cre- ates warm air currents.These cur- rents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall cover- ings or operating heater where impurities (such as tobacco smoke, aromatic candles, clean- ing fluids, oil or kerosene lamps, etc.) in the air exist may discolor walls.

6

Image 6
Contents OWNER’S Operation and Installation Manual MN060HBA MN100HBA MN100TBASafety Information Product Features Determining FRESH-AIR Flow for Heater Location Fresh AIR for Combustion VentilationProviding Adequate Ventilation Determining if you have a Confined or Unconfined SpaceAIR for Combustion Ventilation Ventilation AIR Ventilation Air from Inside BuildingVentilation AIR InstallationInstallation Needs Locating HeaterInstallation Installing Thermostat Sensing BulbInstalling Bottom Mounting Screw Placing Heater On Mounting BracketConnecting to GAS Supply Typical Inlet Pipe DiametersNON-THERMOSTAT Model NFOR Your SAFETYnChecking GAS Connections Read Before LightingProcedure InstructionsGAS to Appliance Read Before Lighting Operating Your HeaterThermostat Model To ApplianceCleaning Maintenance Operating HeaterTroubleshooting Observed Problem Possible Cause RemedyObserved Problem Possible Cause RemedyHeater produces unwanted odors Specifications Illustrated Parts Breakdown MN060HBAParts List MN060HBA KEY DescriptionMN100HBA Parts List MN100HBA MN100TBA Parts List MN100TBA KEY Description QTY
Related manuals
Manual 24 pages 28.45 Kb

MN100TBA, MN060HBA, MN100HBA specifications

Procom has made a significant mark in the world of communications technology with its line of radio communication equipment, including the MN060HBA, MN100TBA, and MN100HBA models. These devices are designed to enhance communication capabilities across various sectors, offering advanced features and technologies that cater to both professional and industrial needs.

The Procom MN060HBA is a highly versatile handheld radio that operates within the 6 MHz bandwidth. Known for its robust build quality, the MN060HBA supports multiple frequency ranges, enabling users to communicate across a broad spectrum. It's equipped with a powerful battery that ensures extended operational time, making it suitable for long-term use in demanding environments. Additional features include a user-friendly interface, programmable channels, and encryption capabilities, providing secure communication for mission-critical applications.

Next, the MN100TBA model stands out with its unique tri-band frequency capabilities, allowing seamless communication across different bands. This model is particularly beneficial for users who require flexibility in their communication methods. The MN100TBA incorporates advanced noise-canceling technology, ensuring clear audio even in noisy surroundings. Its rugged design adheres to IP standards, offering resistance against dust and moisture, making it ideal for outdoor operations. Moreover, the device is equipped with a high-resolution display, allowing users to access information and settings quickly.

On the other hand, the MN100HBA is engineered for high-performance applications, featuring dual-band operation that strikes a perfect balance between range and clarity. This model is tailored for professional use, boasting superior audio quality and a comprehensive suite of features, including GPS for location tracking and emergency alerts. The MN100HBA also supports various modulation schemes, delivering flexibility depending on operational needs. With a rechargeable battery and efficient power management system, users can depend on this model for extended periods, even during intensive use.

In summary, Procom’s MN060HBA, MN100TBA, and MN100HBA represent the forefront of radio communication technology. Each model offers unique features tailored to specific user requirements, including durability, multi-band operation, and advanced audio quality. These devices are designed to stand the test of time, offering reliable performance in challenging environments, thereby making them essential tools for professionals in diverse industries.