Procom MN100HBA, MN060HBA, MN100TBA Connecting to GAS Supply, Typical Inlet Pipe Diameters

Page 9
Installation must include an equip- ment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be up stream from heater (see Figure 13).

INSTALLATION

CONNECTING TO GAS SUPPLY

WARNING: A qualified service person must connect heater gas supply. Follow all local codes.

WARNING: This appliance requires a 3/8" NPT (National Pipe Thread) inlet connection to the pressure regulator.

WARNING: Never connect heater to private (non-utility) gas well. This gas is commonly known as well-head gas.

IMPORTANT: Check your gas line pressure before connecting heater to gas line. Gas line pressure must be no greater than 10.5 inches of water. If gas line pressure is higher, heater regulator damage could occur.

 

CAUTION: Use

only

new,

Figure 13 -Gas Connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

black

iron

or

steel

pipe.

*A CSA/AGA design-certified equipment shutoff valve with 1/8" NPT tap is

Internally-tinned copper tubing

may be used in certain areas.

an acceptable alternative to test gauge connection. Purchase the

optional

Check

your local codes. Use pipe

CSA/AGA design-certified equipment

shutoff

valve

 

from

of

large enough

diameter to

your dealer. See Accessories, page 17.

 

 

 

 

 

 

allow proper gas volume to heater.

IMPORTANT: Install an equipment

Install sediment

trap

in supply line

If

pipe

is

too

small,

shutoff

valve

in

an

accessible

as shown in

 

Figure 13.

Locate

undue

loss

of pressure will

 

location. The

equipment

shutoff

sediment

trap

where it is

within

occur.

 

 

 

 

 

 

 

 

 

 

valve

is

for

turning on

or shutting

reach

for

cleaning.

Locate

 

 

 

 

 

 

 

Typical Inlet Pipe Diameters

 

off the

gas

to

the

appliance.

sediment

trap where

trapped

 

 

 

 

 

 

 

 

 

 

matter is not likely to freeze. A

All models up to 20,000 BTU’s use

Apply

pipe

joint

sealant

lightly to

sediment

trap

traps

moisture and

3/8’’ or greater pipe;

 

 

 

male

threads.

 

This will

prevent

contaminants.

 

This

keeps

them

All models 25,000 BTU’s and higher,

 

 

excess

sealant

from

going into

from going into

heater controls. If

use 1/2” or greater pipe.

 

 

 

 

pipe. Excess sealant in pipe could

sediment

trap

is

not

installed

or is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

result in

clogged

heater

valves.

installed

wrong,

heater

may

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

not run properly.

 

 

 

CAUTION: Use pipe joint sealant that is resistant to natural gas.

IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping and/or fittings.

9

Image 9
Contents MN060HBA MN100HBA MN100TBA OWNER’S Operation and Installation ManualSafety Information Product Features Providing Adequate Ventilation Fresh AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Determining if you have a Confined or Unconfined SpaceVentilation Air from Inside Building AIR for Combustion Ventilation Ventilation AIRInstallation Needs InstallationVentilation AIR Locating HeaterInstalling Thermostat Sensing Bulb InstallationPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewTypical Inlet Pipe Diameters Connecting to GAS SupplyChecking GAS Connections NFOR Your SAFETYnNON-THERMOSTAT Model Read Before LightingProcedure InstructionsGAS to Appliance Thermostat Model Operating Your HeaterRead Before Lighting To ApplianceOperating Heater Cleaning MaintenanceObserved Problem Possible Cause Remedy TroubleshootingPossible Cause Remedy Observed ProblemHeater produces unwanted odors Specifications MN060HBA Illustrated Parts BreakdownKEY Description Parts List MN060HBAMN100HBA Parts List MN100HBA MN100TBA KEY Description QTY Parts List MN100TBA
Related manuals
Manual 24 pages 28.45 Kb

MN100TBA, MN060HBA, MN100HBA specifications

Procom has made a significant mark in the world of communications technology with its line of radio communication equipment, including the MN060HBA, MN100TBA, and MN100HBA models. These devices are designed to enhance communication capabilities across various sectors, offering advanced features and technologies that cater to both professional and industrial needs.

The Procom MN060HBA is a highly versatile handheld radio that operates within the 6 MHz bandwidth. Known for its robust build quality, the MN060HBA supports multiple frequency ranges, enabling users to communicate across a broad spectrum. It's equipped with a powerful battery that ensures extended operational time, making it suitable for long-term use in demanding environments. Additional features include a user-friendly interface, programmable channels, and encryption capabilities, providing secure communication for mission-critical applications.

Next, the MN100TBA model stands out with its unique tri-band frequency capabilities, allowing seamless communication across different bands. This model is particularly beneficial for users who require flexibility in their communication methods. The MN100TBA incorporates advanced noise-canceling technology, ensuring clear audio even in noisy surroundings. Its rugged design adheres to IP standards, offering resistance against dust and moisture, making it ideal for outdoor operations. Moreover, the device is equipped with a high-resolution display, allowing users to access information and settings quickly.

On the other hand, the MN100HBA is engineered for high-performance applications, featuring dual-band operation that strikes a perfect balance between range and clarity. This model is tailored for professional use, boasting superior audio quality and a comprehensive suite of features, including GPS for location tracking and emergency alerts. The MN100HBA also supports various modulation schemes, delivering flexibility depending on operational needs. With a rechargeable battery and efficient power management system, users can depend on this model for extended periods, even during intensive use.

In summary, Procom’s MN060HBA, MN100TBA, and MN100HBA represent the forefront of radio communication technology. Each model offers unique features tailored to specific user requirements, including durability, multi-band operation, and advanced audio quality. These devices are designed to stand the test of time, offering reliable performance in challenging environments, thereby making them essential tools for professionals in diverse industries.