Procom MN060HBA, MN100HBA, MN100TBA installation manual Heater produces unwanted odors

Page 16

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating beater where impurities in air exist may create odors. Clean- ing supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

OBSERVED PROBLEM

Heater produces unwanted odors.

POSSIBLE CAUSE

 

 

REMEDY

1. Heater

is burning

vapors

from

1.

Ventilate room. Stop using odor

paint,

hair spray,

glues,

etc.

 

causing products while heater

(See

IMPORTANT statement

 

is running.

above).

 

 

 

2.

Locate and correct all leaks(see

2. Gas leak. See Warning

Statement at top of page.

 

 

Checking Gas Connections,

 

 

 

 

 

page 10).

Heater shuts off in use (ODS operates). 1.

Not enough fresh air is available.

1.

Open window

and/or

door

for

 

 

 

ventilation.

 

 

 

2.

Low line pressure.

2.

Contact local

natural

gas

 

 

 

company.

 

 

 

3.

ODS/pilot is partially clogged.

3.

Clean ODS/pilot (see

Cleaning

 

 

 

page 12).

 

 

 

Gas odor exists even when control knob is in OFF position.

Gas odor during combustion.

1. Gas leak. See Warning

1.

Locate and correct all leaks(see

Statement at top of page.

 

Checking

Gas Connections,

 

 

page 10).

 

2. Control valve is defective.

2.

Replace control valve.

1.Foreign matter between control 1. Take apart gas tubing and

valve and burner.

remove foreign matter.

2. Gas

leak.

See Warning

2. Locate and correct all leaks

Statement at top of page.

(see Checking Gas Connections,

 

 

 

page 10).

Moisture/condensation noticed on

1. Not enough combustion/ventilation

1. Refer to Air for Combustion and

windows.

air.

Ventilation requirements, page

 

 

4.

1 6

Image 16
Contents OWNER’S Operation and Installation Manual MN060HBA MN100HBA MN100TBASafety Information Product Features Fresh AIR for Combustion Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Determining if you have a Confined or Unconfined SpaceAIR for Combustion Ventilation Ventilation AIR Ventilation Air from Inside BuildingInstallation Installation NeedsVentilation AIR Locating HeaterInstallation Installing Thermostat Sensing BulbInstalling Bottom Mounting Screw Placing Heater On Mounting BracketConnecting to GAS Supply Typical Inlet Pipe DiametersNFOR Your SAFETYn Checking GAS ConnectionsNON-THERMOSTAT Model Read Before LightingInstructions ProcedureGAS to Appliance Operating Your Heater Thermostat ModelRead Before Lighting To ApplianceCleaning Maintenance Operating HeaterTroubleshooting Observed Problem Possible Cause RemedyObserved Problem Possible Cause RemedyHeater produces unwanted odors Specifications Illustrated Parts Breakdown MN060HBAParts List MN060HBA KEY DescriptionMN100HBA Parts List MN100HBA MN100TBA Parts List MN100TBA KEY Description QTY
Related manuals
Manual 24 pages 28.45 Kb

MN100TBA, MN060HBA, MN100HBA specifications

Procom has made a significant mark in the world of communications technology with its line of radio communication equipment, including the MN060HBA, MN100TBA, and MN100HBA models. These devices are designed to enhance communication capabilities across various sectors, offering advanced features and technologies that cater to both professional and industrial needs.

The Procom MN060HBA is a highly versatile handheld radio that operates within the 6 MHz bandwidth. Known for its robust build quality, the MN060HBA supports multiple frequency ranges, enabling users to communicate across a broad spectrum. It's equipped with a powerful battery that ensures extended operational time, making it suitable for long-term use in demanding environments. Additional features include a user-friendly interface, programmable channels, and encryption capabilities, providing secure communication for mission-critical applications.

Next, the MN100TBA model stands out with its unique tri-band frequency capabilities, allowing seamless communication across different bands. This model is particularly beneficial for users who require flexibility in their communication methods. The MN100TBA incorporates advanced noise-canceling technology, ensuring clear audio even in noisy surroundings. Its rugged design adheres to IP standards, offering resistance against dust and moisture, making it ideal for outdoor operations. Moreover, the device is equipped with a high-resolution display, allowing users to access information and settings quickly.

On the other hand, the MN100HBA is engineered for high-performance applications, featuring dual-band operation that strikes a perfect balance between range and clarity. This model is tailored for professional use, boasting superior audio quality and a comprehensive suite of features, including GPS for location tracking and emergency alerts. The MN100HBA also supports various modulation schemes, delivering flexibility depending on operational needs. With a rechargeable battery and efficient power management system, users can depend on this model for extended periods, even during intensive use.

In summary, Procom’s MN060HBA, MN100TBA, and MN100HBA represent the forefront of radio communication technology. Each model offers unique features tailored to specific user requirements, including durability, multi-band operation, and advanced audio quality. These devices are designed to stand the test of time, offering reliable performance in challenging environments, thereby making them essential tools for professionals in diverse industries.