Napco Security Technologies GEM-DXRP1 Turning OFF the AL ARM Disarming When Returning, Al Ar M

Page 10

TURNING OFF THE AL ARM (DISARMING) WHEN RETURNING

D I S AR M S YS TE M E N TR Y TI M E X X X

I N V AL I D EN TR Y TR Y AG AI N

Disarming the System

1Enter your premises through the Entry/Exit door. The keypad will sound a steady or pulsing tone to remind you to disarm the system before your Entry Delay time expires.

2Enter your User Code and press D. The red ARMED light will go out, indicating that the system has been disarmed. If you enter an invalid code, the keypad will beep 4 times, signifying an error. Re-enter your code immediately. 10 seconds before Entry Delay expires, the keypad will emit a pulsing warning tone.

 

Alarm Indication / Silencing an Alarm

**** AL AR M ****

If the red ARMED light is flashing and “ALARM” is displayed, an alarm occurred while you were

 

out. Proceed with caution! If you suspect that an intruder may still be on the premises, leave

 

immediately and call authorities from a neighbor's phone.

 

0 2 - B AC K DO OR

To silence an audible alarm:

1 Enter your code and press J. After the system is disarmed, the window will continue

 

 

to display “ALARM” followed by the zone(s) violated.

 

0 3 - LI V IN G R OO M

2 To reset the display, note the zones violated, then press C.

 

Ambush (Optional) Your Ambush Code Type is: ‰TYPE 1 (Prefix) ‰TYPE 2 (Unique)

 

My Ambush Code is ___________________

If an intruder forces you to disarm your system, enter your Ambush Code and press J. There are two types of Ambush Codes:

(1)A 2-digit code (prefix) entered just prior to your normal User Code and (2) A separate and unique User Code.

Example Type 1 (Prefix): If your User Code is 1234 and your Ambush Code is 99, press 991234J.

Example Type 2 (Unique): If your User Code is 1234 and your Ambush Code is 8899, press 8899J

Using your Ambush Code will send a silent alarm to the central station. The red ARMED light will go out and the window will display “SYSTEM READY” as if the system were normally disarmed. There will be no indication that a silent alarm has been sent.

10

Image 10
Contents Operating Guide for your Introduction Important Test Your System WeeklyTable of Contents Keypad Controls & Indicators GEM-P3200/9600 panels only Setting the Alarm Arming When Leaving System ReadySystem Trouble W B AT TE R Y E02-00 ServiceAN ’ T AR M S YS TE M P R E SS R E SE T K EY Bypassed S YS TE M R E AD Y Protecting Yourself While on the PremisesInstant Protection Bypassing Interior Zones‰ Press Eto activate Easy Exit on your system Turning OFF the AL ARM Disarming When Returning AL AR MFire-Zone Trouble Fire-Zone AlarmFire Protection Fire F I RE AL AR MPreparing a Fire Escape Plan Would You Like More Safety Information?Important! Read Carefully Floorplan FloorplanLimitations of Fire Alarm Warning System Keypad Functions S PL AY F AU L TS B YP AS S E D Y/N D I RE C to R Y Y /NP3200 control panels only S E T YS TR B L N SO R M SG Y/ N AR T I T TI M E 1 4 H RS AC TI V ATE AL E R TE S T Y/ N To AR ME SS AC TI V ATE OGR AM Y/N OWN L O AD Y/N L AY On TR OL Y/ N Communicator Features Central Station MonitoringExit-Delay Restart Advanced FeaturesSecurity Bypass/Unbypass AC TI V ATE OGR AM TE R U S ER C O DE 567 Enter the User Program ModeProgramming Optional Programming / Reprogramming a User CodeReviewing a Programmed User Code Exiting the User Program ModeProgramming Example Entering a new zone description Cell Phone-Style Entry Enter the User Program ModeProgramming Zone Descriptions AC TI V ATE OGR AM Y/NEnter Zone Descriptions -- Cell Phone Style Example Repeatedly press 3 to display G H I 3 in sequenceProgramming the Time Programming the system Date and TimeProgramming the Date TE R TI MEYS TE M R E AD Y C D ATE TI M E Keypad MessagesYS TE M AR M E D I D ATE TI M E AL AR M FI RE TR BL FI RE AL AR M For partitioned systems only. Code not valid for areaW B AT TE R Y E 0 2 0 0 S ER V IC E AT TE M P TI N G to C AN C E L AL AR M C AN C E L EDYS TE M TRB L OMM F AI LGlossary AreaGlossary Glossary System Trouble Error Codes Trouble System Trouble Action Indication ConditionE05-NN E04-NNE06-NN E12-NN E10-NNE11-NN E13-NNE22-NN E41-NN Troubleshooting What do I do if For more infoPage Napco Limited Warranty Following Statement is Required by the FCC

GEM-DXRP1 specifications

Napco Security Technologies has long been a reputable name in the security solutions industry, and the GEM-DXRP1 is a testament to that legacy. This state-of-the-art digital communicator is designed to enhance the security infrastructure of any facility or residence, bridging the gap between traditional alarm systems and advanced monitoring technologies.

One of the standout features of the GEM-DXRP1 is its enhanced communication capabilities. It utilizes both digital and IP-based communication to ensure reliable and seamless interaction between security panels and central monitoring stations. This dual communication approach significantly improves the reliability of alarm signals and provides users with peace of mind knowing that their security system is always connected.

The GEM-DXRP1 supports advanced technologies such as GSM, allowing for cellular monitoring and providing an additional layer of redundancy to traditional landline systems. In an era where connectivity and immediate response are crucial, the use of GSM technology allows for instant communication of alarm signals, ensuring timely responses to emergencies.

Another notable characteristic is its user-friendly interface. The device features easy-to-navigate programming capabilities, making it simple for installers to integrate it into existing security systems. The intuitive design also aids users in accessing vital system information and configuring settings without complicated procedures.

Additionally, the GEM-DXRP1 is equipped with robust security features. It supports encrypted communication, protecting transmitted data from unauthorized access, thus ensuring the integrity of alarm signals and user information. This focus on security reflects Napco’s commitment to providing not only functionality but also safeguarding user privacy.

Compatibility is another critical aspect of the GEM-DXRP1. The device can be integrated with various Napco security panels, making it a versatile choice for upgrading existing systems. Its scalable design allows for future expansion, accommodating additional zones and devices as security needs evolve.

In conclusion, the GEM-DXRP1 by Napco Security Technologies exemplifies modern security technology with its enhanced communication capabilities, user-friendly interface, and robust security features. As security concerns continue to grow, tools like the GEM-DXRP1 offer essential solutions for both residential and commercial applications, ensuring that safety is always a top priority. With its blend of reliability, functionality, and security, the GEM-DXRP1 stands out as a valuable addition to any security infrastructure.