Napco Security Technologies GEM-DXRP1 manual Reviewing a Programmed User Code, Programming Example

Page 23

PROGRAMMING (OPTIONAL)

Reviewing a Programmed User Code

To review an existing User Code, enter the user number and the corresponding User Code will display.

Exiting the User Program Mode

When you have completed programming or erasing User Codes, press Cto exit the User Program Mode.

Programming Example:

Program the User 3 Code to “3784”:

1.Enter your User Code, followed by A.

2.Answer NO (press F) repeatedly until “ACTIVATE PROGRAM Y/N” is displayed, then press YES (E). The display will read: “ENTER USER CODE”

3.Press 03for User No. 3, then press AA, followed by 3784.

4.Press J to save the code. Note: Duplicate Codes are not allowed; therefore a duplicate Code entered in the

LCD Window will erase when D is pressed. Press Cto exit the Program Mode.

Notes:

If the system contains more than one keypad, only the keypad designated “No. 1” may be used for programming (if in doubt which is No. 1, ask your installer).

While in Program Mode, the ARMED and STATUS lights remain off and burglar and fire alarm functions are disabled.

In selecting your codes, do not program repetitive numbers (1111), consecutive numbers (1234), your birth date, address, or other obvious combinations. Choose a code of up to six digits (a minimum of four is recommended, and required in UL installations). If the keypad detects no Program Mode activity for more than 4 minutes, a tone will sound. Press Cto silence.

23

Image 23
Contents Operating Guide for your Important Test Your System Weekly IntroductionTable of Contents Keypad Controls & Indicators GEM-P3200/9600 panels only System Ready Setting the Alarm Arming When LeavingAN ’ T AR M S YS TE M P R E SS R E SE T K EY W B AT TE R Y E02-00 ServiceSystem Trouble Bypassing Interior Zones Protecting Yourself While on the PremisesInstant Protection Bypassed S YS TE M R E AD Y‰ Press Eto activate Easy Exit on your system AL AR M Turning OFF the AL ARM Disarming When ReturningFire F I RE AL AR M Fire-Zone AlarmFire Protection Fire-Zone TroubleImportant! Read Carefully Would You Like More Safety Information?Preparing a Fire Escape Plan Floorplan FloorplanLimitations of Fire Alarm Warning System S PL AY F AU L TS B YP AS S E D Y/N D I RE C to R Y Y /N Keypad FunctionsP3200 control panels only S E T YS TR B L N SO R M SG Y/ N AR T I T TI M E E SS AC TI V ATE AL E R TE S T Y/ N To AR M1 4 H RS AC TI V ATE OGR AM Y/N OWN L O AD Y/N L AY On TR OL Y/ N Central Station Monitoring Communicator FeaturesSecurity Bypass/Unbypass Advanced FeaturesExit-Delay Restart Programming / Reprogramming a User Code 567 Enter the User Program ModeProgramming Optional AC TI V ATE OGR AM TE R U S ER C O DEProgramming Example Exiting the User Program ModeReviewing a Programmed User Code AC TI V ATE OGR AM Y/N Enter the User Program ModeProgramming Zone Descriptions Entering a new zone description Cell Phone-Style EntryExample Repeatedly press 3 to display G H I 3 in sequence Enter Zone Descriptions -- Cell Phone StyleTE R TI ME Programming the system Date and TimeProgramming the Date Programming the TimeYS TE M AR M E D I D ATE TI M E Keypad MessagesYS TE M R E AD Y C D ATE TI M E For partitioned systems only. Code not valid for area AL AR M FI RE TR BL FI RE AL AR MOMM F AI L AT TE M P TI N G to C AN C E L AL AR M C AN C E L EDYS TE M TRB L W B AT TE R Y E 0 2 0 0 S ER V IC EArea GlossaryGlossary Glossary Trouble System Trouble Action Indication Condition System Trouble Error CodesE06-NN E04-NNE05-NN E13-NN E10-NNE11-NN E12-NNE22-NN E41-NN What do I do if For more info TroubleshootingPage Following Statement is Required by the FCC Napco Limited Warranty

GEM-DXRP1 specifications

Napco Security Technologies has long been a reputable name in the security solutions industry, and the GEM-DXRP1 is a testament to that legacy. This state-of-the-art digital communicator is designed to enhance the security infrastructure of any facility or residence, bridging the gap between traditional alarm systems and advanced monitoring technologies.

One of the standout features of the GEM-DXRP1 is its enhanced communication capabilities. It utilizes both digital and IP-based communication to ensure reliable and seamless interaction between security panels and central monitoring stations. This dual communication approach significantly improves the reliability of alarm signals and provides users with peace of mind knowing that their security system is always connected.

The GEM-DXRP1 supports advanced technologies such as GSM, allowing for cellular monitoring and providing an additional layer of redundancy to traditional landline systems. In an era where connectivity and immediate response are crucial, the use of GSM technology allows for instant communication of alarm signals, ensuring timely responses to emergencies.

Another notable characteristic is its user-friendly interface. The device features easy-to-navigate programming capabilities, making it simple for installers to integrate it into existing security systems. The intuitive design also aids users in accessing vital system information and configuring settings without complicated procedures.

Additionally, the GEM-DXRP1 is equipped with robust security features. It supports encrypted communication, protecting transmitted data from unauthorized access, thus ensuring the integrity of alarm signals and user information. This focus on security reflects Napco’s commitment to providing not only functionality but also safeguarding user privacy.

Compatibility is another critical aspect of the GEM-DXRP1. The device can be integrated with various Napco security panels, making it a versatile choice for upgrading existing systems. Its scalable design allows for future expansion, accommodating additional zones and devices as security needs evolve.

In conclusion, the GEM-DXRP1 by Napco Security Technologies exemplifies modern security technology with its enhanced communication capabilities, user-friendly interface, and robust security features. As security concerns continue to grow, tools like the GEM-DXRP1 offer essential solutions for both residential and commercial applications, ensuring that safety is always a top priority. With its blend of reliability, functionality, and security, the GEM-DXRP1 stands out as a valuable addition to any security infrastructure.