The GEM-DXRP1 is a “smart” user- friendly, interactive menu-driven keypad designed for your Napco control panel. Its alphanumeric screen will not only display the status of your system, but will also give you step-by-step instructions to guide you through all operations.

This booklet contains important information about the operation of your system with this GEM-DXRP1 Keypad. Read it carefully and keep it handy for

future reference. Check the Glossary for an explanation of terms that may be unfamiliar to you.

You'll probably find subjects mentioned in this booklet that do not apply to your system. Napco control panels have such a wide variety of features that few security systems, if any, will ever need them all. Your alarm professional has chosen appropriate features for your particular needs.

Regardless of how your system has been configured, rest assured that it has been carefully designed and engineered to the highest industry standards. To assure optimum safety and security, familiarize yourself with this equipment. Periodically check its condition and state of readiness by testing it at least once a week in both the ac/battery and battery-only modes (ask your alarm professional how to make these tests).

IMPORTANT - TEST YOUR SYSTEM WEEKLY

Test your sounding device and backup battery

Test your central station communicator

 

(These tests should only be performed on weekends or at a time

(Activate Dialer Test programmed? ‰YES ‰NO)

 

 

designated by your alarm company.)

1.

Notify your Central Station of the impending test.

 

 

1. While disarmed, press A.

A

 

2.

While disarmed, enter your User Code and press

.

2. Answer NO (press

) until “ACTIVATE BELL TEST” appears in

 

 

 

 

the window.

F

3.

Answer NO (press F) until “ACTIVATE DIALER TEST” appears

3. Press YES (E) to execute the test. The alarm will sound for

 

in the window.

 

 

 

4.

Press YES (

) to send a test code to the central station.

about two seconds.

 

 

E

 

 

 

If the alarm does not sound, call for service.

If the test is not successful, “COMM FAIL E03-00 SERVICE” will

If the battery is low, “LOW BATTERY E02-00 SERVICE” will appear

display, indicating a communication failure. Call for service.

 

 

in the display indicating a low battery condition. Allow 24 hours for

Note: Any subsequent successful transmission will clear a “Failure to

 

the battery to recharge. If the trouble continues, call for service.

 

Communicate” system trouble.

 

 

2

Image 2
Contents Operating Guide for your Introduction Important Test Your System WeeklyTable of Contents Keypad Controls & Indicators GEM-P3200/9600 panels only Setting the Alarm Arming When Leaving System ReadyAN ’ T AR M S YS TE M P R E SS R E SE T K EY W B AT TE R Y E02-00 ServiceSystem Trouble Bypassed S YS TE M R E AD Y Protecting Yourself While on the PremisesInstant Protection Bypassing Interior Zones‰ Press Eto activate Easy Exit on your system Turning OFF the AL ARM Disarming When Returning AL AR MFire-Zone Trouble Fire-Zone AlarmFire Protection Fire F I RE AL AR MImportant! Read Carefully Would You Like More Safety Information?Preparing a Fire Escape Plan Floorplan FloorplanLimitations of Fire Alarm Warning System Keypad Functions S PL AY F AU L TS B YP AS S E D Y/N D I RE C to R Y Y /NP3200 control panels only S E T YS TR B L N SO R M SG Y/ N AR T I T TI M E E SS AC TI V ATE AL E R TE S T Y/ N To AR M1 4 H RS AC TI V ATE OGR AM Y/N OWN L O AD Y/N L AY On TR OL Y/ N Communicator Features Central Station MonitoringSecurity Bypass/Unbypass Advanced FeaturesExit-Delay Restart AC TI V ATE OGR AM TE R U S ER C O DE 567 Enter the User Program ModeProgramming Optional Programming / Reprogramming a User CodeProgramming Example Exiting the User Program ModeReviewing a Programmed User Code Entering a new zone description Cell Phone-Style Entry Enter the User Program ModeProgramming Zone Descriptions AC TI V ATE OGR AM Y/NEnter Zone Descriptions -- Cell Phone Style Example Repeatedly press 3 to display G H I 3 in sequenceProgramming the Time Programming the system Date and TimeProgramming the Date TE R TI MEYS TE M AR M E D I D ATE TI M E Keypad MessagesYS TE M R E AD Y C D ATE TI M E AL AR M FI RE TR BL FI RE AL AR M For partitioned systems only. Code not valid for areaW B AT TE R Y E 0 2 0 0 S ER V IC E AT TE M P TI N G to C AN C E L AL AR M C AN C E L EDYS TE M TRB L OMM F AI LGlossary AreaGlossary Glossary System Trouble Error Codes Trouble System Trouble Action Indication ConditionE06-NN E04-NNE05-NN E12-NN E10-NNE11-NN E13-NNE22-NN E41-NN Troubleshooting What do I do if For more infoPage Napco Limited Warranty Following Statement is Required by the FCC

GEM-DXRP1 specifications

Napco Security Technologies has long been a reputable name in the security solutions industry, and the GEM-DXRP1 is a testament to that legacy. This state-of-the-art digital communicator is designed to enhance the security infrastructure of any facility or residence, bridging the gap between traditional alarm systems and advanced monitoring technologies.

One of the standout features of the GEM-DXRP1 is its enhanced communication capabilities. It utilizes both digital and IP-based communication to ensure reliable and seamless interaction between security panels and central monitoring stations. This dual communication approach significantly improves the reliability of alarm signals and provides users with peace of mind knowing that their security system is always connected.

The GEM-DXRP1 supports advanced technologies such as GSM, allowing for cellular monitoring and providing an additional layer of redundancy to traditional landline systems. In an era where connectivity and immediate response are crucial, the use of GSM technology allows for instant communication of alarm signals, ensuring timely responses to emergencies.

Another notable characteristic is its user-friendly interface. The device features easy-to-navigate programming capabilities, making it simple for installers to integrate it into existing security systems. The intuitive design also aids users in accessing vital system information and configuring settings without complicated procedures.

Additionally, the GEM-DXRP1 is equipped with robust security features. It supports encrypted communication, protecting transmitted data from unauthorized access, thus ensuring the integrity of alarm signals and user information. This focus on security reflects Napco’s commitment to providing not only functionality but also safeguarding user privacy.

Compatibility is another critical aspect of the GEM-DXRP1. The device can be integrated with various Napco security panels, making it a versatile choice for upgrading existing systems. Its scalable design allows for future expansion, accommodating additional zones and devices as security needs evolve.

In conclusion, the GEM-DXRP1 by Napco Security Technologies exemplifies modern security technology with its enhanced communication capabilities, user-friendly interface, and robust security features. As security concerns continue to grow, tools like the GEM-DXRP1 offer essential solutions for both residential and commercial applications, ensuring that safety is always a top priority. With its blend of reliability, functionality, and security, the GEM-DXRP1 stands out as a valuable addition to any security infrastructure.