Software Upgrading

How to Upgrade Software Using a Terminal program

Introduction This upgrade process applies to both the Switch Card and

 

remote modules and should take place when both are

 

offline. This procedure only covers the Switch Card

 

software upgrade instructions. Information for upgrading

 

remote modules is found on page 7-10.

 

Note: When using a terminal program for software

 

upgrading, only one Switch Card can be upgraded at a time.

 

Repeat the following procedure for each Switch Card to be

 

upgraded.

Setup

The PC must be connected to the COMA port of the

 

card to be upgraded.

 

Ensure the terminal emulation package is configured for

 

VT100, and the data rate is set to 9.6 Kbps, no parity, 8

 

bits, 1 stop bit.

 

If the Rack is powered up, unplug the Switch Card and

 

re-insert it into the Rack

 

or

 

qIf the Rack is powered down, power up the Rack.

 

The Switch Card status LED will blink as follows;

 

Red flashes, three green flashes, four yellow flashes, then

 

threeq

sets of eight yellow blinks.

During the first set of eight yellow blinks, type the word

MENU from the terminal screen. The Configuration

Menu should appear on the screen.

Procedure

From the Main Menu:

 

1.

Select the Configure System menu option.

 

From the System Menu:

 

2.

Select Software Upgrade. The command will initiate

 

 

the upgrade process.