Lucent Technologies 3100, 3000 manual Error Codes 111A to 124C, Description

Models: 3100 3000

1 144
Download 144 pages 3.44 Kb
Page 111
Image 111

Troubleshooting

Error Codes continued

Error Code

111A

112B

113B

114A

115B

116B

117C

118C

119B

120B

121A

122B

123A

124C

Error Codes

Description

Number of rejected received User Data packets because they were out of sequence.

Number of times maximum number of User Data packet re-transmissions were exceeded.

Number of times User Data channel had to be re-synchronized.

Number of times User Data channel timed out waiting for packet acknowledgment.

Number of times User Data channel discarded data due to receive overflow (probably because host did not observe flow control).

Number of times carrier detect lost from Terminal Adapter.

Number of times Terminal Adapter check failed.

Number of times communications to DSP failed.

Number of times digital port link re- activated.

Number of times digital port connection was lost or de-activated.

Number of times digital port data was re-transmitted.

Number of times IVP (V42) link failed.

Number of times user disconnected by pressing HOLD key 4 times and then disconnecting.

Number of times Synchronous Communications Controller IC transmit locked up.

Cause

Digital port connection to Switch Card may have been lost.

Indicates that the user has disconnected by pressing Hold button 4 times and selecting Disconnect.

Table 6-11. Error Codes 111A to 124C

Issue 1 October 1998 6-17

Page 111
Image 111
Lucent Technologies 3100, 3000 manual Error Codes 111A to 124C, Description