Napco Security Technologies GEM-DXRP1 Preparing a Fire Escape Plan, Important! Read Carefully

Page 12

FIRE PROTECTION

Preparing a Fire Escape Plan

Even with the most advanced fire alarm system, adequate protection requires an escape plan.

To prepare your plan, draw floor plans of your building. (Space is provided on the next page). Show two exits - a front or back door and a window from each room. (Make sure the window works. You may need a special fire-escape ladder if the window is high up). Write down your outside meeting place.

Family Rehearsal.

Rehearse each of the following activities:

1.Everyone in his room with the doors closed.

2.One person sounds the alarm.

3.Each person tests his door.

4.Pretend the door is hot and use the alternate escape exit.

5.Everyone meets outdoors at the assigned spot.

Important! - Read Carefully

Discuss these escape procedures with all those who use the building:

1.In a residence, sleep with the bedroom door closed. A closed door will hold back deadly smoke while you escape.

2.When the fire alarm signals, escape quickly. Do not stop to pack.

3.Test the door. If it is hot, use your alternate route through the window. If the door is cool, brace your shoulder

against it and open it cautiously. Be ready to slam the door if smoke or heat rushes in. Crawl through smoke, holding your breath. Close the doors again on leaving to help prevent the fire from spreading.

4.Go to your specific outdoor meeting place so you can see that everyone is safe.

5.Assign someone to make sure nobody returns to the burning building.

6.Call the Fire Department from a neighbor's telephone.

Would You Like More Safety Information?

For more information on home fire detection, burn safety, and home fire safety, write to the National Fire Protection Association, Public Affairs Dept. 05A, Batterymarch Plaza, Quincy, MA 02269.

12

Image 12
Contents Operating Guide for your Introduction Important Test Your System WeeklyTable of Contents Keypad Controls & Indicators GEM-P3200/9600 panels only Setting the Alarm Arming When Leaving System ReadyW B AT TE R Y E02-00 Service System TroubleAN ’ T AR M S YS TE M P R E SS R E SE T K EY Protecting Yourself While on the Premises Instant ProtectionBypassed S YS TE M R E AD Y Bypassing Interior Zones‰ Press Eto activate Easy Exit on your system Turning OFF the AL ARM Disarming When Returning AL AR MFire-Zone Alarm Fire ProtectionFire-Zone Trouble Fire F I RE AL AR MWould You Like More Safety Information? Preparing a Fire Escape PlanImportant! Read Carefully Floorplan FloorplanLimitations of Fire Alarm Warning System Keypad Functions S PL AY F AU L TS B YP AS S E D Y/N D I RE C to R Y Y /NP3200 control panels only S E T YS TR B L N SO R M SG Y/ N AR T I T TI M E AC TI V ATE AL E R TE S T Y/ N To AR M 1 4 H RSE SS AC TI V ATE OGR AM Y/N OWN L O AD Y/N L AY On TR OL Y/ N Communicator Features Central Station MonitoringAdvanced Features Exit-Delay RestartSecurity Bypass/Unbypass 567 Enter the User Program Mode Programming OptionalAC TI V ATE OGR AM TE R U S ER C O DE Programming / Reprogramming a User CodeExiting the User Program Mode Reviewing a Programmed User CodeProgramming Example Enter the User Program Mode Programming Zone DescriptionsEntering a new zone description Cell Phone-Style Entry AC TI V ATE OGR AM Y/NEnter Zone Descriptions -- Cell Phone Style Example Repeatedly press 3 to display G H I 3 in sequenceProgramming the system Date and Time Programming the DateProgramming the Time TE R TI MEKeypad Messages YS TE M R E AD Y C D ATE TI M EYS TE M AR M E D I D ATE TI M E AL AR M FI RE TR BL FI RE AL AR M For partitioned systems only. Code not valid for areaAT TE M P TI N G to C AN C E L AL AR M C AN C E L ED YS TE M TRB LW B AT TE R Y E 0 2 0 0 S ER V IC E OMM F AI LGlossary AreaGlossary Glossary System Trouble Error Codes Trouble System Trouble Action Indication ConditionE04-NN E05-NNE06-NN E10-NN E11-NNE12-NN E13-NNE22-NN E41-NN Troubleshooting What do I do if For more infoPage Napco Limited Warranty Following Statement is Required by the FCC

GEM-DXRP1 specifications

Napco Security Technologies has long been a reputable name in the security solutions industry, and the GEM-DXRP1 is a testament to that legacy. This state-of-the-art digital communicator is designed to enhance the security infrastructure of any facility or residence, bridging the gap between traditional alarm systems and advanced monitoring technologies.

One of the standout features of the GEM-DXRP1 is its enhanced communication capabilities. It utilizes both digital and IP-based communication to ensure reliable and seamless interaction between security panels and central monitoring stations. This dual communication approach significantly improves the reliability of alarm signals and provides users with peace of mind knowing that their security system is always connected.

The GEM-DXRP1 supports advanced technologies such as GSM, allowing for cellular monitoring and providing an additional layer of redundancy to traditional landline systems. In an era where connectivity and immediate response are crucial, the use of GSM technology allows for instant communication of alarm signals, ensuring timely responses to emergencies.

Another notable characteristic is its user-friendly interface. The device features easy-to-navigate programming capabilities, making it simple for installers to integrate it into existing security systems. The intuitive design also aids users in accessing vital system information and configuring settings without complicated procedures.

Additionally, the GEM-DXRP1 is equipped with robust security features. It supports encrypted communication, protecting transmitted data from unauthorized access, thus ensuring the integrity of alarm signals and user information. This focus on security reflects Napco’s commitment to providing not only functionality but also safeguarding user privacy.

Compatibility is another critical aspect of the GEM-DXRP1. The device can be integrated with various Napco security panels, making it a versatile choice for upgrading existing systems. Its scalable design allows for future expansion, accommodating additional zones and devices as security needs evolve.

In conclusion, the GEM-DXRP1 by Napco Security Technologies exemplifies modern security technology with its enhanced communication capabilities, user-friendly interface, and robust security features. As security concerns continue to grow, tools like the GEM-DXRP1 offer essential solutions for both residential and commercial applications, ensuring that safety is always a top priority. With its blend of reliability, functionality, and security, the GEM-DXRP1 stands out as a valuable addition to any security infrastructure.