Napco Security Technologies GEM-DXRP1 manual Al Ar M Fi Re Tr Bl Fi Re Al Ar M

Page 28

KEYPAD MESSAGES

* * * * AL AR M* * * *

** * FI RE TR BL * **

** * FI RE AL AR M * * *

C ODE DE N IE D

I N COR RE C T AR E A

I N V AL I D EN TR Y TR Y AG AI N

C AN ’ T AR M S YS TE M /

AR E A # I N TR O UBL E

Alarm condition, followed by zone description(s). “ALARM” and zones will display after system is disarmed. Note zones, then press Cto clear keypad.

(With pulsing sounder.) Trouble condition on a Fire Zone. Press Cto silence sounder. Correct trouble or call for service.

(With pulsing sounder.) Alarm condition on a Fire Zone. Press Cto silence sounder. Evacuate premises or correct cause of alarm.

(For partitioned systems only.) Code not valid for area.

Wrong code entered or “Easy Bypass” function not enabled.

(In Global Arming Mode). Arming prevented due to unsecured zone. “#” represents number of area with unsecured zone. Press area number, then G, then J to view zones in that area. Correct problem, then arm as normal. (For GEM-P1664/3200/9600 panels only).

28

Image 28
Contents Operating Guide for your Introduction Important Test Your System WeeklyTable of Contents Keypad Controls & Indicators GEM-P3200/9600 panels only Setting the Alarm Arming When Leaving System ReadySystem Trouble W B AT TE R Y E02-00 ServiceAN ’ T AR M S YS TE M P R E SS R E SE T K EY Protecting Yourself While on the Premises Instant ProtectionBypassed S YS TE M R E AD Y Bypassing Interior Zones‰ Press Eto activate Easy Exit on your system Turning OFF the AL ARM Disarming When Returning AL AR MFire-Zone Alarm Fire ProtectionFire-Zone Trouble Fire F I RE AL AR MPreparing a Fire Escape Plan Would You Like More Safety Information?Important! Read Carefully Floorplan FloorplanLimitations of Fire Alarm Warning System Keypad Functions S PL AY F AU L TS B YP AS S E D Y/N D I RE C to R Y Y /NP3200 control panels only S E T YS TR B L N SO R M SG Y/ N AR T I T TI M E 1 4 H RS AC TI V ATE AL E R TE S T Y/ N To AR ME SS AC TI V ATE OGR AM Y/N OWN L O AD Y/N L AY On TR OL Y/ N Communicator Features Central Station MonitoringExit-Delay Restart Advanced FeaturesSecurity Bypass/Unbypass 567 Enter the User Program Mode Programming OptionalAC TI V ATE OGR AM TE R U S ER C O DE Programming / Reprogramming a User CodeReviewing a Programmed User Code Exiting the User Program ModeProgramming Example Enter the User Program Mode Programming Zone DescriptionsEntering a new zone description Cell Phone-Style Entry AC TI V ATE OGR AM Y/NEnter Zone Descriptions -- Cell Phone Style Example Repeatedly press 3 to display G H I 3 in sequenceProgramming the system Date and Time Programming the DateProgramming the Time TE R TI MEYS TE M R E AD Y C D ATE TI M E Keypad MessagesYS TE M AR M E D I D ATE TI M E AL AR M FI RE TR BL FI RE AL AR M For partitioned systems only. Code not valid for areaAT TE M P TI N G to C AN C E L AL AR M C AN C E L ED YS TE M TRB LW B AT TE R Y E 0 2 0 0 S ER V IC E OMM F AI LGlossary AreaGlossary Glossary System Trouble Error Codes Trouble System Trouble Action Indication ConditionE05-NN E04-NNE06-NN E10-NN E11-NNE12-NN E13-NNE22-NN E41-NN Troubleshooting What do I do if For more infoPage Napco Limited Warranty Following Statement is Required by the FCC

GEM-DXRP1 specifications

Napco Security Technologies has long been a reputable name in the security solutions industry, and the GEM-DXRP1 is a testament to that legacy. This state-of-the-art digital communicator is designed to enhance the security infrastructure of any facility or residence, bridging the gap between traditional alarm systems and advanced monitoring technologies.

One of the standout features of the GEM-DXRP1 is its enhanced communication capabilities. It utilizes both digital and IP-based communication to ensure reliable and seamless interaction between security panels and central monitoring stations. This dual communication approach significantly improves the reliability of alarm signals and provides users with peace of mind knowing that their security system is always connected.

The GEM-DXRP1 supports advanced technologies such as GSM, allowing for cellular monitoring and providing an additional layer of redundancy to traditional landline systems. In an era where connectivity and immediate response are crucial, the use of GSM technology allows for instant communication of alarm signals, ensuring timely responses to emergencies.

Another notable characteristic is its user-friendly interface. The device features easy-to-navigate programming capabilities, making it simple for installers to integrate it into existing security systems. The intuitive design also aids users in accessing vital system information and configuring settings without complicated procedures.

Additionally, the GEM-DXRP1 is equipped with robust security features. It supports encrypted communication, protecting transmitted data from unauthorized access, thus ensuring the integrity of alarm signals and user information. This focus on security reflects Napco’s commitment to providing not only functionality but also safeguarding user privacy.

Compatibility is another critical aspect of the GEM-DXRP1. The device can be integrated with various Napco security panels, making it a versatile choice for upgrading existing systems. Its scalable design allows for future expansion, accommodating additional zones and devices as security needs evolve.

In conclusion, the GEM-DXRP1 by Napco Security Technologies exemplifies modern security technology with its enhanced communication capabilities, user-friendly interface, and robust security features. As security concerns continue to grow, tools like the GEM-DXRP1 offer essential solutions for both residential and commercial applications, ensuring that safety is always a top priority. With its blend of reliability, functionality, and security, the GEM-DXRP1 stands out as a valuable addition to any security infrastructure.