Napco Security Technologies GEM-DXRP1 manual E41-NN

Page 37

SYSTEM TROUBLE ERROR CODES

Trouble

System Trouble

Action

Indication

Condition

 

 

 

 

E40-00

RF Self Test Failure

A wireless motion sensor on the zone indicated has failed its automatic self test routine.

 

 

Call installing company for service.

E41-NN

Fire Trouble

A problem has been detected on the Fire zone indicated. Call installing company for service.

 

 

(GEM-P1632, GEM-P816 and GEM-P1664 panels only).

E51-00

Bell/Siren Trouble

There is a problem with the Bell or Siren. Call installing company for service.

 

 

 

E58-00

Telemetry Trouble

Call installing company for service.

 

 

 

E59-00

Telemetry Failure

Call installing company for service.

 

 

 

E66-00

Dirty Smoke Detector

Clean Smoke Detector or call installing company for service.

 

 

 

E99-00

Keypad Panic Shorted

Call installing company for service.

 

too Long

 

37

Image 37
Contents Operating Guide for your Important Test Your System Weekly IntroductionTable of Contents Keypad Controls & Indicators GEM-P3200/9600 panels only System Ready Setting the Alarm Arming When LeavingSystem Trouble W B AT TE R Y E02-00 ServiceAN ’ T AR M S YS TE M P R E SS R E SE T K EY Instant Protection Protecting Yourself While on the PremisesBypassed S YS TE M R E AD Y Bypassing Interior Zones‰ Press Eto activate Easy Exit on your system AL AR M Turning OFF the AL ARM Disarming When ReturningFire Protection Fire-Zone AlarmFire-Zone Trouble Fire F I RE AL AR MPreparing a Fire Escape Plan Would You Like More Safety Information?Important! Read Carefully Floorplan FloorplanLimitations of Fire Alarm Warning System S PL AY F AU L TS B YP AS S E D Y/N D I RE C to R Y Y /N Keypad FunctionsP3200 control panels only S E T YS TR B L N SO R M SG Y/ N AR T I T TI M E 1 4 H RS AC TI V ATE AL E R TE S T Y/ N To AR ME SS AC TI V ATE OGR AM Y/N OWN L O AD Y/N L AY On TR OL Y/ N Central Station Monitoring Communicator FeaturesExit-Delay Restart Advanced FeaturesSecurity Bypass/Unbypass Programming Optional 567 Enter the User Program ModeAC TI V ATE OGR AM TE R U S ER C O DE Programming / Reprogramming a User CodeReviewing a Programmed User Code Exiting the User Program ModeProgramming Example Programming Zone Descriptions Enter the User Program ModeEntering a new zone description Cell Phone-Style Entry AC TI V ATE OGR AM Y/NExample Repeatedly press 3 to display G H I 3 in sequence Enter Zone Descriptions -- Cell Phone StyleProgramming the Date Programming the system Date and TimeProgramming the Time TE R TI MEYS TE M R E AD Y C D ATE TI M E Keypad MessagesYS TE M AR M E D I D ATE TI M E For partitioned systems only. Code not valid for area AL AR M FI RE TR BL FI RE AL AR MYS TE M TRB L AT TE M P TI N G to C AN C E L AL AR M C AN C E L EDW B AT TE R Y E 0 2 0 0 S ER V IC E OMM F AI LArea GlossaryGlossary Glossary Trouble System Trouble Action Indication Condition System Trouble Error CodesE05-NN E04-NNE06-NN E11-NN E10-NNE12-NN E13-NNE22-NN E41-NN What do I do if For more info TroubleshootingPage Following Statement is Required by the FCC Napco Limited Warranty

GEM-DXRP1 specifications

Napco Security Technologies has long been a reputable name in the security solutions industry, and the GEM-DXRP1 is a testament to that legacy. This state-of-the-art digital communicator is designed to enhance the security infrastructure of any facility or residence, bridging the gap between traditional alarm systems and advanced monitoring technologies.

One of the standout features of the GEM-DXRP1 is its enhanced communication capabilities. It utilizes both digital and IP-based communication to ensure reliable and seamless interaction between security panels and central monitoring stations. This dual communication approach significantly improves the reliability of alarm signals and provides users with peace of mind knowing that their security system is always connected.

The GEM-DXRP1 supports advanced technologies such as GSM, allowing for cellular monitoring and providing an additional layer of redundancy to traditional landline systems. In an era where connectivity and immediate response are crucial, the use of GSM technology allows for instant communication of alarm signals, ensuring timely responses to emergencies.

Another notable characteristic is its user-friendly interface. The device features easy-to-navigate programming capabilities, making it simple for installers to integrate it into existing security systems. The intuitive design also aids users in accessing vital system information and configuring settings without complicated procedures.

Additionally, the GEM-DXRP1 is equipped with robust security features. It supports encrypted communication, protecting transmitted data from unauthorized access, thus ensuring the integrity of alarm signals and user information. This focus on security reflects Napco’s commitment to providing not only functionality but also safeguarding user privacy.

Compatibility is another critical aspect of the GEM-DXRP1. The device can be integrated with various Napco security panels, making it a versatile choice for upgrading existing systems. Its scalable design allows for future expansion, accommodating additional zones and devices as security needs evolve.

In conclusion, the GEM-DXRP1 by Napco Security Technologies exemplifies modern security technology with its enhanced communication capabilities, user-friendly interface, and robust security features. As security concerns continue to grow, tools like the GEM-DXRP1 offer essential solutions for both residential and commercial applications, ensuring that safety is always a top priority. With its blend of reliability, functionality, and security, the GEM-DXRP1 stands out as a valuable addition to any security infrastructure.