SMART I/O User’s Manual | Chapter 6 Communications Modules  | |||
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
6.2.13 ISaGRAF Programming
6.2.13.1 The ISaGRAF Board Parameters
Because this module has not been defined as a physical board in the ISaGRAF project, it has been created as a function block as shown in figure 6.2.13.1.1.
Figure 6.2.13.1.1 Function block of the SM-SSI  Module
Command
One of:
FB_SSI_INIT
FB_SSI_SETPOINT
This is the command that must be executed to initialize the module before operating the SSI interface - normally at the beginning of an ISaGRAF program cycle. Also, prior to using this call, if the ctrlx variables have been defined with a value, then these will be sent to the 
This gives the user the possibility to enter a value for the comparator register when testing for a match between the actual 
  | 
  | 
  | 
  | 