Pepper Computer RS232, RS485 user manual SMADCReadConverted Syntax

Models: RS485 RS232

1 320
Download 320 pages 36.43 Kb
Page 239
Image 239
SUCCESS E_MNF
E_PARAM E_NOTRDY

Chapter 5 Analog Modules

SMART I/O User’s Manual

 

 

 

 

 

 

 

 

 

 

5.3.8.17SMADCReadConverted

Syntax

error_code SMADCReadConverted(u_int8 PortNr, u_int8 channel, double *pBuffer);

Description

This function reads the converted value of the last AD Conversion and stores the value in degrees Celcius in a user defined buffer. The user has to take care that the buffer is large enough to store the data.

Input

u_int8 PortNr

u_int8 channel double *pBuffer

Output

error_code

Example

Port number from which the input is read (from 0 to 10)

Number of the channel to be read (0 to 3) Pointer to a user defined buffer

If wrong type of module or no module is fitted on the selected port

If wrong channel number is specified If no data is available at the moment or the sensor is defect.

- wait or poll the input or check sensor or standard OS-9 error code (refer to the OS-9 Technical Manual Error Codes Section).

5

RetVal = SMADCReadConverted(0, 1, &Buffer);

 

 

 

 

March 12, 1996

©1996 PEP Modular Computers GmbH

Page 5 - 83

 

 

Page 239
Image 239
Pepper Computer RS232, RS485 user manual SMADCReadConverted Syntax