SMART I/O User’s Manual

Chapter 4 Digital Modules

 

 

 

 

 

 

 

 

 

 

4.2.8‘C’ Programming 4.2.8.1 SM-DOUT1 Library

The SM-DOUT1 library of functions smartio.l provide a convenient way of accessing the SM-DOUT1 module.

All functions are written in ANSI C;

Prototypes are to be found in the file dout1lib.h.

Hardware Requirements

SMART I/O Base Module or Base Module and Extension unit;

SM-DOUT1 Module.

Software Requirements

The compiler from one of the following:

Ultra C Version 1.1.2 or higher;

FasTrak 2.0.2 or higher.

The leftmost SM-Module has number 0 assigned to it a far as programming is concerned although physically this is slot 1!

Before a library function can be used, the function SMDOUT1Init must first be called. This allocates the requested resources. Furthermore, this function needs to be called for each SM-DOUT1 Module called within the task. Upon completion of the application, the function SMDOUT1DeInit needs to be called for each SM-DOUT1 Module that has been initialised.

In order to illustrate the use of the SM-DOUT1 library, an application example called demdout1.c can be found in the SMART I/O application directory (normally found in /<device>/APPLIC/SMART/CMDS).

 

 

 

 

Page

4 - 24

©1996 PEP Modular Computers GmbH

March 12, 1996

 

 

 

Page 112
Image 112
Pepper Computer RS485, RS232 user manual 8 ‘C’ Programming 4.2.8.1 SM-DOUT1 Library, Hardware Requirements