Pepper Computer RS485, RS232 user manual SMADCGetMode Syntax

Models: RS485 RS232

1 320
Download 320 pages 36.43 Kb
Page 232
Image 232

SMART I/O User’s Manual

Chapter 5 Analog Modules

 

 

 

 

 

 

 

 

 

 

5.3.8.10SMADCGetMode

Syntax

error_code SMADCGetMode(u_int8 PortNr, u_int8 channel, u_int8 *pBuffer);

Description

This function checks if an SM-THERM board is fitted on the specified port and if the channel is valid. It gets the mode setting of the channel and stores the value in a user defined buffer. The user has to take care that the buffer is large enough to store the data.

Input

u_int8 PortNr

u_int8 channel u_int8 *pBuffer

Output

error_code

Example

Port number to fetch the mode (0 to 10)

Number of specified channel (0 to 3) Pointer to a user defined buffer

SUCCESS

E_MNF If wrong type of module or no module is fitted on the selected port

E_PARAM If wrong channel number is specified or standard OS-9 error code (refer to the OS-9 Technical Manual Error Codes Section).

RetVal = SMADCGetMode(0, 1, &Buffer);

 

 

 

 

Page

5 - 76

©1996 PEP Modular Computers GmbH

March 12, 1996

 

 

 

Page 232
Image 232
Pepper Computer RS485, RS232 user manual SMADCGetMode Syntax