Chapter 5 Analog Modules | SMART I/O User’s Manual | |||
|
|
|
|
|
|
|
|
|
|
To compile the source, execute the following commands at the shell prompt:
>chd /<dev>/APPLIC/SMART
>make all
To execute the example:
load | /<dev>/BSP/SMART/SMADC/adc_task | * load HW task |
load | /<dev>/APPLIC/SMART/CMDS/demoadc | * load example |
demoadc [slot]
Slot = 0,1 .. 10 specifies the port of the
Note that the procedure names are generic and are applicable to both the
Initialization
To start the HW Task, the
Read RAW Data
To force the HW task to read RAW data from a channel, the function SMADCEnableRead must be called. As soon as the HW task has received data from this channel, a flag is set indicating a valid RAW value. Now the user’s application is able to read this value by using the function SMADCReadRaw.
5
|
|
|
|