A complete list of the operate COMMANDS may be obtained by selecting a project from the ISaGRAF projects group, opening an application and observing the Common defines in the Dictionary
O_INIT_CODE : The syntax and usage have already been explained.
O_SERIAL_READ : This operate call prevents the system from being blocked due to polling of incoming characters. Hence, during every ISaGRAF cycle, the program checks if the buffer for incoming data contains data. If so, the data will be collected. The syntax is as follows:
<chars_in> := OPERATE(<ser_in>,O_SERIAL_READ,<chars>);
where <chars_in>
<ser_in> <chars>
represents the actual number of characters read from the buffer.
is the input device name.
the number of characters expected to be read.
Example |
| |
6 | ||
ret := OPERATE(keyboard, O_SERIAL_READ, 10); | ||
If the default value 0D hex is used for the eor_char then the scanning of |
| |
the input will terminate when either the <RETURN> key is pressed or 10 |
| |
characters have been read. |
|
|
|
|
|