Introduction

SMART I/O User’s Manual

 

 

 

 

 

 

 

 

 

 

1.4.5 Battery Installation

The battery piggyback SMPBBAT is fitted into the socket BU3 on the SMART-BASE. It is important that the piggyback is inserted in the correct way. The figure below illustrates this procedure.

Figure 1.4.5.1: Battery Piggyback Installation

Pin 5

 

 

BU3

Battery

 

 

 

 

 

 

 

Pin 1

 

 

 

 

SMPBLED

 

 

 

 

SMPBBAT

 

 

Battery

Type

3V Lithium BR2032

3V Lithium CR14250

Battery

Capacity

190mAh

 

850mAh

Typical Data Retention Time *140 Days

 

590 Days

* this is the time without the main power being applied

WARNING!

Once fitted on the board, the battery should be on the right hand side of the SMPBBAT piggyback. If the battery needs to be replaced, it must only be done with a replacement SMPBBAT piggyback, the order number of which is shown in the Ordering Information section of this manual.

The temperature on the battery must not exceed +70°C, due to the risk of battery damage! For SMART I/O modules with extended temperature ranges of up to 85°C, a special lithium battery must be fitted to the SMPBBAT.