SMART I/O User’s Manual | Chapter 5 Analog Modules | |||
|
|
|
|
|
|
|
|
|
|
5.3.8.2SMADCInit Syntax
error_code SMADCInit(u_int8 PortNr);
Description
This function initializes the
- provides an internal list of known sensors (contact PEP Modular Computers for advice on sensors not included in this list)
- creates or links the data module for communication with HW task (the module name is ‘ADC_Data’)
- starts the task accessing the Hardware (HW task)
- prepares parameters depending on the used
Input
u_int8 PortNr
Output
error_code
Example
Port number of module to initialize (from 0 to 10)
SUCCESS
E_MNF If wrong type of module or no module is fitted on the selected port
E_PRCABT If starting of the HW task failed or standard
RetVal = SMADCInit(0);
|
|
|
|
Page | 5 - 68 | ©1996 PEP Modular Computers GmbH | March 12, 1996 |
|
|
|