RoboteQ AX3500 user manual RS-232 Watchdog, Controller Commands and Queries, Type, Description

Models: AX3500

1 208
Download 208 pages 62.24 Kb
Page 142
Image 142
RS-232 Watchdog

Serial (RS-232) Controls and Operation

RS-232 Watchdog

For applications demanding the highest operating safety, the controller may be configured to automatically stop the motors (but otherwise remain fully active) if it fails to receive a character on its RS232 port for more than 1 seconds.

The controller will also send a “W” character every second to indicate to the microcom- puter that such a time-out condition has occurred.

The character does not need to be a specific command, but any ASCII code, including invis- ible ones.

The RS232 watchdog is enabled or disabled depending on the value of the “Input Com- mand Mode” parameter.

The RS232 watchdog is automatically enabled when entering the RS232 mode from the RC or from the Analog modes (see “Entering RS232 from R/C or Analog mode” on page 140)

Controller Commands and Queries

AX3500 commands and queries are composed of a series of 2 or 4 characters followed by the “enter” (carriage return) code.

The controller will send back (echo) every character it is receiving. By checking that the returned character is the same as the one sent, it is possible to verify that there has been no error in communication.

After a command has been received and properly executed, the controller will send the “+” character.

If a command has been received with errors or bad parameters, the controller will send the “-” character.

The table below lists the AX3500 RS232 commands and queries

TABLE 24. Controller’s basic Commands and Queries

Command

Type

Description

 

 

 

%rrrrrr

Command

Reset Controller

 

 

 

!Ann

Command

Channel 1, forward command to value nn

 

 

 

!ann

Command

Channel 1, reverse command to value nn

 

 

 

!Bnn

Command

Channel 2, forward command to value nn

 

 

 

!bnn

Command

Channel 2, reverse command to value nn

 

 

 

!C

Command

Turn Accessory Output C n

 

 

 

!c

Command

Turn Accessory Output C Off

 

 

 

?a or ?A

Query

Read Battery Amps

 

 

 

?v or ?V

Query

Read Power Level applied to motors

 

 

 

?p or ?P

Query

Read Analog Inputs 1 and 2

 

 

 

?r or ?R

Query

Read Analog Inputs 3 and 4

 

 

 

142

AX3500 Motor Controller User’s Manual

Version 1.9b. June 1, 2007

Page 142
Image 142
RoboteQ AX3500 RS-232 Watchdog, Controller Commands and Queries, Serial RS-232 Controls and Operation, Type, Description