RoboteQ AX3500 user manual Analog Feedback on Single Channel Controllers, Important Notice

Models: AX3500

1 208
Download 208 pages 62.24 Kb
Page 93
Image 93
Analog Feedback on Single Channel Controllers

Analog Feedback on Single Channel Controllers

Analog Feedback on Single Channel Controllers

On Single Channel controllers (SC Version - not to be confused with Dual Channel control- lers of which only one channel is used for position control - See “Single Channel Opera- tion” on page 177.), the controller accepts one command and uses one input for feedback.

Feedback Wiring in RC or RS232 Mode on Single Channel Controllers

When the controller is configured for RS232 or RC command, the wiring of the feedback must be done as shown in the figure below.

14 +5V

2k - 10k

5 Ground

11 Ana1

Feedback

10 Ana2

12 Ana3*

8 Ana4*

FIGURE 60. Pot wiring on Single Channel controllers (SCversion) and Analog Command

Feedback Wiring in Analog Mode on Single Channel Controllers

When the controller is configured in Analog mode, the analog input 1 is used for com- mands while the analog input 4 is used for feedback. Note that the analog inputs 3 and 4 are only available on the AX3500 with PCB revision 3.0 or above. The revision number is marked on the PCB. Roborun will detect the new hardware revision and display Rev B on the screen.

2k

2k - 10k

Command

Feedback

14 +5V

5 Ground

11 Ana1

10 Ana2

12 Ana3*

8 Ana4*

FIGURE 61. Pot wiring on Single Channel controllers (SC version) and Analog Command

Analog inputs 3 and 4 have different characteristics than inputs 1 and 2, and so require a lower resistance potentiometer in order to guarantee accuracy.

Important Notice

AX3500 Motor Controller User’s Manual

93

Page 93
Image 93
RoboteQ AX3500 Analog Feedback on Single Channel Controllers, Feedback Wiring in Analog Mode on Single Channel Controllers