RoboteQ AX3500 user manual Encoder Module Parameters Setting, Encoder Setting and Testing

Models: AX3500

1 208
Download 208 pages 62.24 Kb
Page 189
Image 189
Encoder Setting and Testing

Encoder Setting and Testing

1

4

 

 

6

2

5

 

3

 

7

7

FIGURE 107. Encoder setup and test screen on Roborun

With this utility, the following actions can be accomplished:

Set and program the Encoder module’s parameters in EEPROM

Activate the motors in each direction at variable speed

View the measured encoder counts

View the measured encoder speed

View the status of the Limit Switches

The screen is composed of the following buttons and displays:

1- Setting of the Encoder’s threshold level - Disabled on AX3500

2- Setting of the Time Base for speed computation

3- Setting Divider for computing relative distance

4- Measure and display speed and relative distance

5- Measure and display counter values

6- Detect and display optional limit switch status

7- Start/Stop communication with controller

8- Set motor speed and direction for testing

Encoder Module Parameters Setting

The Encoder module has four programmable parameters: Two Time Bases (one for each encoder), a Divider for computing relative distance, and the voltage threshold for discern- ing a 0 or 1 level at the encoder’s output. In the case of the AX3500, the threshold is fixed at 2.5V and cannot be changed.

AX3500 Motor Controller User’s Manual

189

Page 189
Image 189
RoboteQ Encoder Module Parameters Setting, Encoder Setting and Testing, AX3500 Motor Controller User’s Manual